NFPA 13, 20 and 25 Seminar
Introduction:
Fire Safety is shared responsibility between design professionals, facility managers and building users. TACO (member of DACO group) is pleased to bring NFPA 13, 20 and 25 seminars to Saudi Arabia to publish the professional safety knowledge from the most reputed organization on its field (National Fire Protection Association).
Instructors:
The seminar will be offered by one of NFPA Team from USA.
Seminar Coordinators:
This seminar is coordinated by TACO (member of DACO group). For any question or support please email to : or call 0505468211 (If needed)
Certificates:
A certificate from NFPA USA will be awarded to participants attended 100% of the seminar
Language:
All seminar classes will be delivered in English. No translation services are offered.
Location, Date and Time:
The seminar will be held in RiyadhCity. The exact venue will be communicated to participants 2 weeks before the Seminar starts.
Seminar will be delivered 24 to 28 April 2010 from 08:30 AM to 5:00 PM
Seminar Learning Benefits
NFPA 13 Installation of sprinkler systems 3-day seminar
Upon completion you should be able to:
- Define the organization of NPFA 13 and its general requirements
- Ascertain the hazard classification for occupancy
- Identify and discuss the requirements for the various sprinkler system components
- Recognize the different types of sprinkler system and be familiar with their operation
- Establish installation requirements for various types of sprinklers
- Apply the requirements for system hanging and seismic bracing
- Appraise various system design requirements including: occupancy hazard fire control. Protection of storage occupancies, and protection of special hazard
- Determine the requirements for system design and installation deliverables including: plans and calculations , water supply data , and system acceptance certification
Who will benefit?
Anyone who designs, reviews, or evaluates sprinkler systems including: engineer, plan reviewers, designers, installers, maintenance personnel, inspectors, manufacturers, insurers, and project managers.
NFPA 20 Fire pumps Seminar 1-day seminar, 2007 edition
Upon completion you should be able to:
- Recognize different types of fire pumps and their applications
- Use graphical determinations of fire pumps output
- Differentiate between electric and diesel drivers and controllers
- Identify the correct application and installation of fire pump components
- Evaluate various types of power sources and the requirements for each
- Assure continuity of power
- Describe the difference between National Electric Code® requirements and NFPA 20 requirements
- Commission fire pumps and related equipment
- Determine the appropriate tests , required equipment , and correct test procedures
- Assess fire pump test data
Who Will Benefit?
Anyone involved with the specification, design, installation, maintenance or approval of fire pumps including: engineers, contractors, facilities professionals, and project managers.
NFPA 25Inspection, Testing and Maintenance of Water-Based Fire Protection System 1-day seminar.
Upon completion you should be able to:
- Locate and explain the scope, purpose, definition and reporting requirements of the 2008 edition of NPFA 25
- Recognize the requirements and procedures for the inspection, testing, and maintenance of private service mains, common valve components, system valves, and sprinkler and standpipe systems.
- Plot flow test results to determine causes of water supply problems
- Evaluate system test data
- Differentiate between the types of storage tanks and their inspection and safety concerns
- Identify water spray, foam-water, and foam water spray systems
- Restore obstructed piping
- Recognize the importance of having a procedure to deal with system impairment
Who will benefit?
Maintenance managers, sprinkler system contractors, building owners, fire inspectors, and anyone who inspects tests or maintains water based protection systems.
Registration Form
NFPA Automatic Sprinkler Seminars-April 24-28, 2010
Attendee Name & Information:
Name______
Job Title______
Company Name______
Address______
City______ P.O.Box ______
Country______
Tel______
Fax______
Mobile______
Company Website______
E-Mail: ______
Notes:
- Trainee’s fee is 7500 SAR per single trainee. Early bird discounted fees are as following:
- Discount 1 : For trainees reserved before 18 March 2010 is 6500 SR
- Discount 2 : For trainees reserved before 28 Feb 2010 is 6000. SAR
- Group Discount for 5-9 trainees is according to Discount 1. Bigger group fees are according to Discount 2.
- TRAINEE IS NOT ENTITLED FOR ANY REFUND UPON ABSENCES.
- Participants will receive at the end of the Seminar Program certificates from NFPA.
- Participants are entitled with 1 break and 1 lunch during the event.
- Note: All participants must complete to attend all the courses in able to receive theircertificates
- The location of the Seminar will be announced by email to all trainees 2 weeks before the Seminar starts.
Full payment is required at the time of booking. Payment should be made to:
Dar Alkawashif Co.
The National Commercial Bank
RiyadhCity
Saudi Arabia
I Ban (Account No.) SA46 10000025348651000104
Swift Code: NCB KSA JE
Payment methods:
- Bank deposit / transfer
- Cheque payable to Dar AlKawashif Co.
- Cash deliverable in Dar AlKawashif office
Time Agenda
NFPA TRAINING PROGRAM 13-20-25
24 - 28 April 2010
SEMINAR PROGRAM SCHEDULE:
08: 30 – 9: 45 TRAINING SESSION
09:45 – 10: 15BREAK
10:15 – 01:00 TRAINING SESSION
01:00 – 02:00PRAYER AND LUNCH
02:00 – 03:30TRAINING SESSION
03:30 – 03:45BREAK
03:45 – 05:00TRAINING SESSION
NOTES:
- REGISTRATION WILL START AT 08:00 AM.
Detailed outlines of the Seminars
NFPA 13 Automatic Sprinkler Systems Essentials Seminar
Day 1
Introduction and General Requirements
Classification of Occupancies and Commodities
Systems Components and Hardware
System Requirements
Installation Requirements
Day 2
Installation requirements continued (if needed)
Underground Pipe
Hanging and Bracing
Hanging & Bracing Continued
Design Approaches – Occupancy Hazard
Day 3
Design Approaches – Storage Occupancies
Design Approaches –Storage Occupancies
Design Deliverables – Plans and Calculations
Design Deliverables – Water Supplies
System Acceptance Deliverables
NFPA 20 Fire Pump Seminar
Day 4
Introduction
NFPA 20 Overview
Fire Pump Basics
General Requirements
Electric Drives/Controllers/Power Supply
Diesel Drivers/Controllers
Pump Commissioning
NFPA 25 –Inspection, Testing & Maintenance of Auto Sprinkler Systems
Day 5
Introduction
General Requirements
Sprinkler & Standpipe Systems
Fire Pumps
Fire Pumps contd.
Water Supplies
Valves, Valve Components & Trim
Obstruction Investigation& System Impairments
السعودية الرياض هاتف 4770047-1-966+ فاكس 4770029-1-966+ ص ب 270071 الرياض 11352 س ت 1010149614Saudi Arabia Tel +966-1-4770047 Fax +966-1-4770029 P.O.Box 270071Riyadh11352 C.R 1010149614
Page 1 of 8