Mycobacterium Testing By PCR

Sampling: swabbing.

Frogs were swabbed utilizing Medical Wire & Equipment Co (UK) MW 100-100 (Figure 1). Swabbed frogs were caught, isolated, identified and weighed before swab samples were taken aseptically from the posterior (back) and anterior (stomach) sides together with the undersides of feet and legs. The swabbing was done comprehensively repeating 2 or 3 times per area. The samples were then stored at 4C to inhibit growth of other microorganisms. The largest problem associated with specimen collection is known to be contamination, thus care was taken to avoid cross contamination. This was done by changing gloves when handling different frogs, changing buckets and water regularly, and storing samples as soon as taken.

Extraction and homogenization of nucleic acids from samples.

30 to 40 mg of Zirconium/silica beads (Biospec. Products) measuring 0.5 mm diameter were weighed into separate Eppendorf centrifuge tubes. These were sterilized by placing them for 5 minutes under a UV light and 50l of PrepMan Ultra (Applied Biosystems) was then added to each tube.

Swabs were broken into each labeled 1.5ml Eppendorf tube and homogenized for 45 seconds in a Mini Beadbeater 8, followed by 1-minute centrifugation at 13000 x gm in a microfuge. The homogenization and centrifugation was repeated to recover all material at the bottom of the tube.

The homogenized sample was placed in a heat block for 10 minutes at 100C. An additional pierced lid was employed at this step (Figure 21). This is to trap the vapor formed while the sample boils but allows some steam off to release pressure. After 2-3 minutes of cooling to allow the condensation to liquidize, the sample was once again centrifuged at 13000 x gm for a further 3 minutes. Pierced lids were then removed.

The homogenized samples were stored in the fridge until further use.

Analysis of samples by PCR

Testing for mycobacterium with 95% probability of detecting 2% infected.

PCR reactions were prepared on individual tubes or 96 wells plates which contain 2 replicates of each sample, a positive control and a negative control. Wells were loaded with a total of 25l. Specimen wells contained 24l of Master mix (see table) and 1l of DNA. The positive control had 24l of Master mix and 1l positive DNA. The negative controls were only 24l Master mix and 1l of dH2O.

The amplification conditions utilized were: 2 min 50C, 10 min 90C, 15s 95C, 1 min 60C for a total of 50 cycles.

PCR solutions

Table 1. Standard Master Mix used in PCR for 1 reaction

Component / Volume / Total Volume
PCR Master mix / 12.5l / 25l
Primer (Forward) / 0.5l
Primer (Reverse) / 0.5l
dH2O (ultra pure - sigma) / 10.5l
DNA / 1l

Dilution of stock solutions

Table 2. Solutions and appropriate dilution uses in the Mycobacterium PCR Assay

Solution / Stock concentration / Dilution / Final concentration
DNA sample / 1 / none / 1/1
Primer (Forward) / 100M / 25l of Primer
475l of dH2O / 5M
Primer (Reverse) / 100M / 25l of Primer
475l of dH2O / 5M

Primers Sequences:

Tb11

5’ ACCAACGATGGTGTGTCCAT 3’

Tb12

5’ CTTGTCGAACCGCATACCCT 3’