Inventor Translator Support

Inventor 2009

Translator / Read Versions / Write Versions
Alias (Autodesk Labs) / V10 and later / N/A
CATIA V5 (Autodesk Labs) / R6-R18 / N/A
IGES / All / 5.3
JT (Autodesk Labs) / 7.0 - 9.1 / 7.0 - 9.1
NX / 3-5 / N/A
Parasolid / Up to 19.0 / 9.0-19.0
Pro/ENGINEER / R14 up to Wildfire 3.0 / N/A
Pro/ENGINEER Granite / Up to 4.0 / 1.0 - 4.0
Pro/ENGINEER Neutral / All / All
SAT / 4.0-7.0 / 4.0-7.0
SolidWorks / 2003-2008 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / N/A / All
XGL/ZGL / N/A / All

Inventor 2010

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V5 / R6-R19 / R10-R18
IGES / All / 5.3
JT / 7.0 - 9.1 / 7.0 - 9.1
NX / 3-6 / N/A
Parasolid / Up to 20.0 / 9.0-20.0
Pro/ENGINEER / R14 up to Wildfire 4.0 / N/A
Pro/ENGINEER Granite / Up to 5.0 / 1.0 - 5.0
Pro/ENGINEER Neutral / All / All
Rhino (Autodesk Labs) / Up to 4.0 / N/A
SAT / 4.0-7.0 / 4.0-7.0
SolidWorks / 2003-2009 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / N/A / All
XGL/ZGL / N/A / All

Note:“N/A” means that mode (read or write) is not available for that format.

Inventor 2011

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6-R19 / R10-R19
IGES / All / 5.3
JT / 7.0 - 9.3 / 7.0 - 9.3
NX / 3–6 / N/A
Parasolid / Up to 22.0 / 9.0-22.0
Pro/ENGINEER / R14 up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / 1.0 - 6.0 / 1.0- 6.0
Pro/ENGINEER Neutral / All / All
Rhino (Autodesk Labs) / Up to 4.0 / N/A
SAT / 4.0-7.0 / 4.0-7.0
SolidWorks / 2003-2010 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / N/A / All
XGL/ZGL / N/A / All

Inventor 2012

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6–R20 / R10–R20
IGES / All / 5.3
JT / 7.0 - 9.4 / 7.0 - 9.4
NX / 3 – 7.5 / N/A
Parasolid / Up to 23.0 / 9.0-23.0
Pro/ENGINEER / R14 up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / 1.0 - 6.0 / 1.0- 6.0
Pro/ENGINEER Neutral / All / All
Rhino / Up to 4.0 / N/A
SAT / 4.0-7.0 / 4.0-7.0
SolidWorks / 2003-2010 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / N/A / All
XGL/ZGL / N/A / All

Note:“N/A” means that mode (read or write) is not available for that format.

Inventor 2013

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6 – R21 / R10 – R20
Creo Parametric / 1.0 / N/A
IGES / All / 5.3
JT / 7.0 - 9.5 / 7.0 - 9.5
NX / 3 – 8.0 / N/A
Parasolid / Up to 24.0 / 9.0-24.0
Pro/ENGINEER / R14 up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / 1.0 - 7.0 / 1.0- 7.0
Pro/ENGINEER Neutral / All / All
Rhino / Up to 5.0 / N/A
SAT / 4.0-7.0 / 7.0
SolidWorks / 2003-2012 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / All / All
XGL/ZGL / N/A / All

Inventor 2014

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6 – R22 / R10 – R20
Creo Parametric / 1.0 - 2.0 / N/A
IGES / All / 5.3
JT / 7.0 - 9.5 / 7.0 - 9.5
NX / UG V13 – NX 8.5 / N/A
Parasolid / Up to 25.0 / 9.0-25.0
Pro/ENGINEER / R14 up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / 1.0 - 8.0 / 1.0-8.0
Pro/ENGINEER Neutral / All / All
Rhino / Up to 5.0 / N/A
SAT / 4.0-7.0 / 7.0
SolidWorks / 2001 Plus-2013 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / All / All
XGL/ZGL / N/A / All

Note:“N/A” means that mode (read or write) is not available for that format.

Inventor 2015

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6 – R5-6R2013 / R10 – V5-6R2013
Creo Parametric / 1.0; 2.0 / N/A
IGES / All / 5.3
JT / 7.0 –10.0 / 7.0–10.0
NX / 3 – 8.0 / N/A
Parasolid / Up to 26.0 / 9.0-26.0
Pro/ENGINEER / Up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / Up to 8.0 / 1.0- 8.0
Pro/ENGINEER Neutral / N/A / N/A
Rhino / Up to 5.0 / N/A
SAT / Up to7.0 / 7.0
SolidWorks / 2001 Plus –2014 / N/A
STEP / AP214, AP203E2 / AP214, AP203E2
STL / All / All
XGL/ZGL / N/A / All

Inventor 2016

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6 – R5-6R2014 / R10 – V5-6R2014
Creo Parametric / 1.0 - 3.0 / N/A
IGES / All / 5.3
JT / 7.0 – 10.0 / 7.0 – 10.0
NX / UGV13 – NX 9 / N/A
Parasolid / Up to 27.0 / 9.0-27.0
Pro/ENGINEER / Up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / Up to 9.0 / 1.0- 9.0
Pro/ENGINEER Neutral / N/A / N/A
Rhino / Up to 5.0 / N/A
SAT / Up to 7.0 / 7.0
SolidWorks / 2001 Plus – 2015 / N/A
STEP / AP214, AP203E2, AP242 / AP214, AP203E2, AP242
STL / N/A / N/A
XGL/ZGL / N/A / N/A

Note:“N/A” means that mode (read or write) is not available for that format.

Inventor 2017

Translator / Read Versions / Write Versions
Alias / V10 and later / N/A
CATIA V4 / All / N/A
CATIA V5 / R6 – V5-6R2015 / R10 – V5-6R2015
Creo Parametric / 1.0 - 3.0 / N/A
DWF/DWFx / 6.0 - 7.5 / 7.5
DWG / All / R2000 – R2017
IDF / 2.0 ; 3.0 / N/A
IFC / N/A / IFC 2x3
IGES / All / 5.3
JT / 7.0 – 10.0 / 7.0 – 10.0
NX / UG V13 – NX 10 / N/A
OBJ / N/A / N/A
Parasolid / Up to 28.0 / 9.0-28.0
Pro/ENGINEER / Up to Wildfire 5.0 / N/A
Pro/ENGINEER Granite / Up to 9.0 / 1.0- 9.0
Pro/ENGINEER Neutral / N/A / N/A
RFA / N/A / R2017
Rhino / Up to 5.0 / N/A
RVT / Up to R2017 / N/A
SAT / Up to 7.0 / 7.0
SolidWorks / 2001 Plus – 2016 / N/A
STEP / AP214, AP203E2, AP242 / AP214, AP203E2, AP242
STL / N/A / N/A
SMT / Up to ASM222 / ASM222
XGL/ZGL / N/A / N/A

Note:“N/A” means that mode (read or write) is not available for that format.

3 October 2018Page 1