S2 | Tegular lay-in system
Pos............ m²
Pos......
...... m²
Pos......
...... running m / Delivery and installation of durlum metal tiles forsystem S2.
The sharp-edged metal tiles are hung into a special substructure via a positive connection and tension-free. The metal tiles can be dismounted without using tools. This guarantees free access to the ceiling void.
Tolerances and quality requirements according to TAIM, DIN EN 13964 and durlum Standards.
Material: Optionally galvanized sheet steel, aluminium or stainless steel
Thickness: Depending on the static requirements
Surface finish: Powder-coatedsimilar to RAL 9010,
optional with RAL ......
Coating thickness:Approx. 60µm
Perforation: durlum Type RG-L15 [2.5/5.5], 16.20% free cross-section
Sound absorption:With a special black durlum acoustic fleece w=approx. 0.73
Dimensions: • Module 600, T24: 575x575mm
• Module 600, T15: 584x584mm
• Module 625, T24: 600x600mm
€/m²
Delivery and installation of a durlum system S2 substructureconsisting of the white painted carriers T24 [optionally T15]. They have been manufactured from coil-coated material in a roll forming process.
The carriers are suspended from the bare ceiling at a spacing of 1200mm [module 600] or 1250mm [module 625] with nonius suspension elements [rigidly] or quick fixing hangers using officially approved dowels.
The spacing of the suspension hangers depends on the requirements of DINEN13964 and the statics of the system and must be proven and established by the contractor.
The carriers have punched slots in the vertical ligaments, into which cross carriers T24 [T15] 1200mm or 1250mm in length are snap-fitted at the module spacing.
T24 [T15] profiles 600 and 625mm in length are snap-fitted in the punched slots friction-locked.
Ensure horizontal and flush alignment during installation of the grid thus formed.
You have to use constructions, which areapproved by the manufacturerof the metal tiles.
€/m²
Delivery and installation of durlum wall connection profiles.
Surface finish: Powder-coatedsimilar to RAL 9010,
optional with RAL ......
Profile:•Perimeter trim F025 made of aluminium
•Perimeter trim F2025 made of aluminium
•Perimeter trim L015 made of aluminium
•Perimeter trim W014 made of steel
•Picture-rail trim 031 made of aluminium
The gap between the metal tiles, the wall connection profiles and the bottom edge of the carrier must be closed with the edge filler panel U1007.
€/running m