Design and implement a multi-location, private inter-networking strategy for a small, stable commercial organization. This organization currently has 3 locations as indicated in the diagram on page 1, all located in the continental United States.

Procedure:

Phase 1:

1.  Work independently; determine the router position and addressing scheme for the network pictured below; use network address 172.16.1.0/24

2.  You will need to use Variable Length Subnet Masking (VLSM) to accomplish the IP addressing scheme.

List the Network and Prefix below for each LAN and WAN segment:

LANs / Network / Prefix
Tampa
Atlanta
Boston / LAN 1
LAN 2
WANs / Network / Prefix
Tampa-to-Atlanta
Atlanta-to-Boston
Device / Interface / IP Address / Subnet Mask / Default Gateway
Tampa-RT / S0/0/0
G0/0
Atlanta-RT / S0/0/0
S0/0/1
G0/0
Boston-RT / S0/0/1
G0/0
G0/1
S1 (Tampa) / VLAN 1
S2 (Atlanta) / VLAN 1
S3(Boston) / VLAN 1
S4 (Boston) / VLAN 1
Tampa host
Atlanta Host
Boston Host 1
Boston Host 2

Phase 2:

Devices and Specifications: Select the appropriate number of devices (switches, Routers and WICs) to meet the network design requirements.

Switch Considerations: Each location (LAN) is fairly small; the number of devices per location is listed in diagram-1. The number of switches required at each location will be determined base on the number of hosts connected to the LAN and the number of available ports per switch. All switches must be accessed virtually for management purposes.

Router Considerations: Corporate headquarters is located in Boston. Connection to the Internet and the associated Internet-related security considerations are to be provided by another company in a future project. The only consideration required at this time is that each location requires one router to provide WAN connectivity to other location(s); each router should have the capability to connect successfully to no more than two full T1 circuits. All routers must be accessed virtually for management purposes.

Phase 3:

1.  Construct the network in Packet Tracer and use the classless network address 172.16.1.0/24 for addressing.

2.  Use RIP Version 2 as a routing protocol. Commands are listed on the diagram. Use clock rate 64000 for serial “DCE” interfaces (refer to Basic Configuration sheet for commands).

Configuration task on each router:

·  Configure the Router’s Name

·  Secure the Routers.

·  Configure the Ethernet Interface

·  Configure the Serial Interfaces

·  Configure the Routing Protocol (RIP version 2)

Items to be configured on the Routes

Configuring the Router:

·  Host Name

·  Message of the day

Configure Router Security:

·  Console
·  Telnet
·  Secret

Configuring the Serial Interface(s):

·  IP address
·  Subnet Mask
·  Interface Description
·  Clock Rate 128000 (when dealing with a DCE end)
·  Activate the interface /

Configuring the Ethernet Interface(s):

·  IP address

·  Subnet Mask

·  Interface Description

·  Activate the interface

Configuring Routing Protocol:

NAME(config)# router rip
NAME(config-router)#version 2
NAME(config-router)# network 172.16.0.0
NAME(config-router)#exit
NAME(config)#exit

Configuration task on each Switch:

·  Configure the Hostname on each switch

·  Secure the Switches.

·  Configure the VLAN 1 Interface on each switch

Design Considerations:

·  All host connections will be 100BaseTx connections (Fast Ethernet)

·  All Uplink connections between router and switch will be 1000BaseTx connections (Gigabit Ethernet)

·  All Serial connections between sites will utilize T1 (1544kbps), point-to-point connections

·  The Company will be using a subnet address 172.16.1.0/24 (Phase 1)

·  The only protocol in use is TCP/IP

·  Routing Protocol is RIP Version 2 (Phase 3)

·  The company wants a simple way to manage connections between sites with a minimum of management by IT personnel (Phase 3)

·  Each location is fairly small; the number of devices per location is listed in the above diagram.

·  Design should reflect the best practices within the networking community.

Deliverables:

·  Use Packet Tracer to configure this network and to verify validity. (Phase 3)

·  Documentation package including:

o  Subnetting scheme. (Phase 1)

o  All configurations (from Routers only)

o  Logical diagram of the network including subnetting scheme. (Phase 3)

o  Physical diagram of the network inkling port numbers and speed.

o  Verification of the network operation using show commands, ping, etc).

·  Detailed Bill of Materials for Router, Switch & WIC. (Phase 2)

o  Half of a page description for each device

§  Make, model, capabilities and specifications

(Example: amount of RAM, flash, number of interfaces, etc….)

o  Detailed Cost Estimate for Routers, Switches & WIC. (Phase 2)

§  In an Excel sheet: Make and model, number of devices, cost per device and total cost.

Completion Criteria:

·  Successful connectivity among all sites. Connectivity is defined by being able to ping from a workstation in Boston to a workstation in all other Locations. Additionally, since there is no support staff in remote locations, Telnet must be enabled from the Boston Location to all remote sites. (Phase 3)

·  Acceptance of detailed documentation package in electronic and hard copy formats by the client.

Class C / 0.192 / 0.224 / 0.240 / 0.248 / 0.252
Subnet / (11000000) / (11100000) / (11110000) / (11111000) / (11111100)
Table / 4 subnets / 62 hosts / 8 subnets / 30 hosts / 16 subnets / 14 hosts / 32 subnets / 6 hosts / 64 subnets / 2 hosts
.0 / .0 ( .1 - .62) / .0 (.1 - .30) / .0 ( .1 - .14) / .0 ( .1 - .6) / .0 ( .1 - .2)
.4 / .4 ( .5 - .6 )
.8 / .8 ( .9 - .14 ) / .8 ( .9 - .10 )
.12 / .12 ( .13 - .14 )
.16 / .16 ( .17 - .30 ) / .16 ( .17 - .22 ) / .16 ( .17 - .18 )
.20 / .20 ( .21 - .22 )
.24 / .24 ( .25 - .30 ) / .24 ( .25 - .26 )
.28 / .28 ( .29 - .30 )
.32 / .32 ( .33 - .62 ) / .32 ( .33 - .46 ) / .32 ( .33 - .38 ) / .32 ( .33 - .34 )
.36 / .36 ( .37 - .38 )
.40 / .40 ( .41 - .46 ) / .40 ( .41 - .42 )
.44 / .44 ( .45 - .46 )
.48 / .48 ( .49 - .62 ) / .48 ( .49 - .54 ) / .48 ( .49 - .50 )
.52 / .52 ( .53 - .54 )
.56 / .56 ( .57 - .62 ) / .56 ( .57 - .58 )
.60 / .60 ( .61 - .62 )
.64 / .64 ( .65 - .126 ) / .64 ( .65 - .94 ) / .64 ( .65 - .78 ) / .64 ( .65 - .70 ) / .64 ( .65 - .66 )
.68 / .68 ( .69 - .70 )
.72 / .72 ( .73 - .78 ) / .72 ( .73 - .74 )
.76 / .76 ( .77 - .78 )
.80 / .80 ( .81 - .94 ) / .80 ( .81 - .86 ) / .80 ( .81 - .82 )
.84 / .84 ( .85 - .86 )
.88 / .88 ( .89 - .94 ) / .88 ( .89 - .90 )
.92 / .92 ( .93 - .94 )
.96 / .96 ( .97 - .126 ) / .96 ( .97 - .110 ) / .96 ( .97 - .102 ) / .96 ( .97 - .98 )
.100 / .100 ( .101 - .102 )
.104 / .104 ( .105 - .110 ) / .104 ( .105 - .106 )
.108 / .108 ( .109 - .110 )
.112 / .112 ( .113 - .126 ) / .112 ( .113 - .118 ) / .112 ( .113 - .114 )
.116 / .116 ( .117 - .118 )
.120 / .120 ( .121 - .126 ) / .120 ( .121 - .122 )
.124 / .124 ( .125 - .126 )
.128 / .128 ( .129 - .190 ) / .128( .129 - .158 ) / .128 ( .129 - .142 ) / .128 ( .129 - .134 ) / .128 ( .129 - .130 )
.132 / .132 ( .133 - .134 )
.136 / .136 ( .137 - .142 ) / .136 ( .137 - .138 )
.140 / .140 ( .141 - .142 )
.144 / .144 ( .145 - .158 ) / .144 ( .145 - .150 ) / .144 ( .145 - .146 )
.148 / .148 ( .149 - .150 )
.152 / .152 ( .153 - .158 ) / .152 ( .153 - .154 )
.156 / .156 ( .157 - .158 )
.160 / .160( .161 - .190 ) / .160 ( .161 - .174 ) / .160 ( .161 - .166 ) / .160 ( .161 - .162 )
.164 / .164 ( .165 - .166 )
.168 / .168 ( .169 - .174 ) / .168 ( .169 - .170 )
.172 / .172 ( .173 - .174 )
.176 / .176 ( .177 - .190 ) / .176 ( .177 - .182 ) / .176 ( .177 - .178 )
.180 / .180 ( .181 - .182 )
.184 / .184 ( .185 - .190 ) / .184 ( .185 - .186 )
.188 / .188 ( .189 - .190 )
.192 / .192 ( .193 - .222 ) / .192 ( .193 - .206 ) / .192 ( .193 - .198 ) / .192 ( .193 - .194 )
.196 / .196 ( .197 - .198 )
.200 / .200 ( .201 - .206 ) / .200 ( .201 - .202 )
.204 / .204 ( .205 - .206 )
.208 / .208 ( .209 - .222 ) / .208 ( .209 - .214 ) / .208 ( .209 - .210 )
.212 / .212 ( .213 - .214 )
.216 / .216 ( .217 - .222 ) / .216 ( .217 - .218 )
.220 / .220 ( .221 - .222 )
.224 / .224 ( .225 - .238 ) / .224 ( .225 - .230 ) / .224 ( .225 - .226 )
.228 / .228 ( .229 - .230 )
.232 / .232 ( .233 - .238 ) / .232 ( .233 - .234 )
.236 / .236 ( .237 - .238 )
.240 / .240 ( .241 - .246 ) / .240 ( .241 - .242 )
.244 / .244 ( .245 - .246 )
.248 / .248 ( .249 - .250 )
.252