SECTION 035413–DUROCK QUIK-TOP GYPSUM CEMENT UNDERLAYMENT

Product Summary:
  • No mechanical preparation required for most applications.
  • Apply floor covering in as little as 15 hours after underlayment application1.
  • Compressive strength up to 10,000 psi (68.9 MPa) with self-sealing technology2.
  • Can be stained, polished or used by itself as a finished floor with an appropriate coating system.
  • Featheredge to 3 in. (76.2 mm) thickness.
  • <insert product representative here> or 800.874.4968 for technical questions.

Note to Specification Writer:
  • This document is not intended to function as a standalone specification. It is intended to assist the specifier in inserting the proper language into the following recommended specification sections: 035413.
  • USG Durock™ Brand Quik-Top™ White and Quik-Top™ Gray Self-Leveling Underlayments are presanded cementitious underlayments designed by USG for interior use in commercial, institutional and rehab construction. They provide a smooth, hard underlayment surface over concrete slabs, prestressed concrete or concrete planks at a typical thickness from featheredge to 3 in. (76.2 mm).
  • An innovative USG technology minimizes downtime with quick set times and high production rates. This allows for trade traffic within hours of installation and installation of floor coverings within 15 hours after the underlayment is poured.

Sustainability Notes:
USG Durock™ Quik-Top White and Quik-Top Gray Self-Leveling Underlayments are defined as “Low Emitting” materials per California Department of Public Health CDPH/EHLB/Standard Method Version 1.1, 2010 (CA Section 01350) for school classroom, single-family residence and private-office modeling scenarios, and meets USGBC’s LEED® v4 emission requirements.

PART 1 - GENERAL

This product requires a minimum maintained temperature for proper curing. This condition is necessary for proper setting.

1.3FIELD CONDITIONS

  1. Environmental Limitations: Comply with manufacturer's written instructions for substrate temperature, ventilation, ambient temperature and humidity, and other conditions affecting underlayment performance.
  2. Place gypsum cement underlayments only when ambient temperature and temperature of substrates is maintained between50-90 degF (10-35 degC).

PART 2 - PRODUCTS

2.2 GYPSUM CEMENT UNDERLAYMENTS

  1. Gypsum Cement Underlayment<INSERT PANEL DESIGNATION HERE>:
  2. Basis of Design: Subject to compliance with project requirements, the design is based on the following: USG Corporation“[USG Durock™ Brand Quik-Top™ White] [USG Durock™ Brand Quik-Top™ Gray]”.
  3. Cement Binder: Gypsum or blended gypsum cement as defined by ASTMC219
  4. Compressive Strength: 7,000-10,000 psi (48.3-68.9 MPa)when tested according to ASTMC109/C109M.
  5. Water:
  6. Potable, free from impurities, cool, clean water and form a domestic source.
  7. Product data:
  8. Approximate Final Set ASTM C191: 60-90 minutes, light foot traffic 2 hours after set. Allows for application of floor covering 15 hours after underlayment application.
  9. Flow time:25minutes
  10. Average Dry Density: 124-130lb/cu. ft.(2-2.08 kg/L).
  11. Thickness: Featheredge to 3” (76.2mm)
  12. Approximate Coverage: 21 square feet per bag at 1/4 in. thickness.
  13. Approximate Flexural Strength ASTM C348: minimum 1,000 psi (6.9 MPa).
  14. Surface pH Range ASTM F710: 11.
  15. Mixing Ratio3.6–5.0 quarts(3.4 to 4.75 liters) of water per 50 lb.(22.7 kg) bag

1)Slump Test: Underlayment mix shall be tested for a slump using a 1” x 2” cylinder resulting in a patty size of 6 1/4”- 6-1/2” for Quik-Top™ Gray and 7”- 7-1/2” for Quik-Top™ White. Slump shall be taken at the beginning of each installation to verify required mix. Slump should be tested periodically thereafter at a minimum of every 2500 sq. ft. to verify it is being maintained.

  1. Primer

For primer application, the temperature, of the subfloor and the room must be maintained between 50°F and 95°F for a period of 48 hours before and after application.

  1. DUROCK™ Brand Primer Sealer.
  2. Coverage: 200-350 square feet per gallon
  3. Drying Time: 3-4 hours
  4. DUROCK™ Brand 3E™ Primer.
  5. Coverage: 600-800 square feet per gallon
  6. Drying Time: 2 hours
  7. DUROCK™ Brand X2™ Primer Sealer.
  8. Coverage: 315-360 square feet per gallon
  9. Drying Time: 4 hours
  1. Accessories
  2. Moisture Vapor Reducer:“USG Durock™ Brand RH-100™ Moisture Vapor Reducer”.
  3. Moisture Vapor Emission Rate Gain (MVER) as defined by ASTM F1869: [Up to 25 lbs./1000 sq. ft./24 hrs][MVERs greater than 25 lbs./1000 sq. ft./24 hrs].
  4. Relative Humidity as defined by ASTM F2170: Withstands Up to 100%
  5. Alkalinity: Resists up to 14 pH
  6. Solids Content: 100%
  7. Tensile Strength as defined by ASTM D638: 2000 psi
  8. VOC: Zero
  9. Approximate Coverage: [375 sq. ft./3-gallon kit at 13 mil] minimum thickness [300 sq. ft./3-gallon kit at 16 mil].
  10. Approximate Working Time: 15 minutes at 77°F
  11. Approximate Curing Time: 4 hours at 77°F
  1. Floor Repair: DUROCK™Brand Advanced Skim Coat™ Floor Patch.
  2. Mixing Ratio: 9 lb. bag USG Durock™ Brand Advanced Skim Coat™ Floor Patch to 2.25 quarts (2.1 liters) of water (three parts Durock Advanced Skim Coat floor patch to one part water by weight)
  3. Approximate Coverage: [76 sq. ft./bag at 1/16 in. thickness] [38 sq. ft./bag at 1/8 in. thickness] [19 sq. ft./bag at 1/4 in. thickness]
  4. Approximate Working Time: 10–15 minutes
  5. Approximate Set Time: 15–30 minutes
  6. Approximate Walkable (light foot traffic): [15–30 minutes (after skim coat set)] [30–45 minutes (after 1/2 in. to 1 in. application set)]
  7. Thickness Range: Featheredge to 1/2 in. in large areas, any thickness in small well defined areas such asthresholds and concave-shaped depressions
  8. DUROCK™ Brand Quik-Ramp™ Floor Patch.
  9. Mixing Ratio: 50 lb. bag USG Durock™ Quik-Ramp floor patch to 4.5–5.5 quarts (4.25–5.20 liters) of water (five parts USG Durock™ Quik-Ramp floor patch to one part water by weight)
  10. Approximate Compressive Strength (aggregated) ASTM C109: (2000 psi2 at 4 hours 3000 psi2 at 24 hours 6000 psi2 at 28 days
  11. Installed Weight2 : 2 lbs./sq. ft. at 1/4 in. thickness
  12. Approximate Coverage : [110–115 sq. ft./bag at 1/16 in. thickness] [55–57.5 sq. ft./bag at 1/8 in. thickness] [27.5–28.75 sq. ft./bag at 1/4 in. thickness]
  13. Approximate Working Time ASTM C191 (modified) : 15–25 minutes at 70°F and 50% Relative humidity
  14. Approximate Final Set ASTM C191: 25–35 minutes (depending on underlayment thickness and drying conditions)
  15. Approximate Walkable (light foot traffic): 30 minutes (after skim coat set)
  16. Thickness Range:

1)Concrete: Skim coat to 2 in. neat; 5 in. when extended

2)Wood: Skim coat to 1/4 in.; up to 3/4 in. in well-defined areas

3)Adhesive Residues: Skim coat to 1/8 in. maximum

4)Nonporous Substrates: Skim coat to 2 in. neat; 5 in. when extended

PART 3 - EXECUTION

3.01EXAMINATION

  1. Site Verification of Conditions:
  1. Subfloor shall be structurally sound. Contractor shall clean subfloor to remove mud, oil, grease, and other contaminating factors before arrival of the licensed applicator.
  2. Verify concrete has been properly cured for at least 28 days and is dry. Perform anhydrous calcium chloride test, ASTM F1869. Proceed with installation only after substrates do not exceed a maximum moisture-vapor-emission rate of 5 lb of water/ per 1000 sq. ft. (1.36 kg of water/100 sq. m) in 24 hours prior to underlayment installation.
  3. If concrete contains greater than 5 lb of water / per 1000 sq. ft., the floor may require moisture mitigation.
  4. Do not proceed with installation until unsatisfactory conditions are corrected.

3.02REQUIREMENTS

  1. Leak Prevention:
  2. Fill cracks and voids in subfloor where leakage of slurry could occur using compressed building insulation, a suitable quick-setting patch material or caulk.
  1. Priming subfloor:
  2. Prime concrete subfloor using Durock®Brand Primer-Sealer according to manufacturer’s recommendations as outlined in submittal sheet.
  3. Install in accordance with reference standards and manufacturer’s instructions and as required to comply with seismic requirements.
  4. Application shall not begin until the building is enclosed, including roof, windows, and doors.

3.03GENERAL INSTALLATION REQUIREMENTS

A. Mixing Proportions

1. Underlayment mix shall be tested for slump using a 2 inch (i.d.)x1 inch cylinder resulting a patty size of 6 ¼” – 6 ½” for Quik-Top Gray and 7 – 7 ½” for Quik-Top (white). Allow 60 seconds to elapse before measuring patty size.

B. Application

1. Place floor topping not to exceed 3” maximum thickness. Immediately

spread and screed product to a smooth surface. At substrate expansion, isolation, and other moving joints, allow joint of same width to continue to through underlayment.

  1. Final Floor Covering
  2. Floor must be dry prior to installation of finished floor or application of floor coatings. At a 1” thickness, Durock® Quik-Top will dry within 15 hours. For thicknesses greater than 1”, consult manufacturer.
  3. Field Quality Control
  4. Underlayment mix shall be tested for a slump using a 2” (i.d.) x 1” cylinder resulting a patty size of 6 ¼” – 6 ½” for Quik-Top Gray and 7 – 7 ½” for Quik-Top (white). Allow 60 seconds to elapse before measuring patty size.
  5. At least one set of three (3) molded cube samples in a brass form shall be taken for every 10,000 sq. ft. Cubes shall be tested in accordance with ASTM C472.

END OF SECTION

Disclaimer: The USG Product Specifications contained herein are intended for use as product reference material by architects, engineers, other design professionals, contractors, building code officials, or other competent construction industry trade professionals having an interest in the selection, specification and use of products manufactured by the subsidiaries of USG Corporation. They are intended solely as technical support incident to the sale and use of our products and not intended to be a substitute for the design review and approval of the licensed design professional for the project. These materials may be printed and/or transferred electronically solely as needed by the user. Because CAD electronic files and BIM (Building Information Modeling) files with the Autodesk Revit Platform can be modified by other parties, without notice or indication of such modifications, modification of USG Product Guide Specifications and Drawings is the sole responsibility of the Design Professional.