aquabasic® PMKF / PMKS
aquabasic® PMKF 20 – 40
92507 / PMKF-basic 20 4.0_105_3/4“aquabasic® cold water meter
Nominal diameter:DN 20
With threaded ends 1"(for couplings 3/4")
Nominal pressure:PN 16 bar
Installation length:105 mm
Installation position:vertical, falling
Temperature max.:40°C
Flow on overload Q4:5 m3/h
Continuous flow Q3:4 m3/h
Transitional flow rate Q2:0.04 m3/h
Min. flow Q1:0.025 m3/h
Measuring range:R160
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
92513 / PMKF-basic 25 6.3_150_1“
aquabasic® cold water meter
Nominal diameter:DN 25
With threaded ends 1 1/4"(for couplings 1")
Nominal pressure:PN 16 bar
Installation length:150 mm
Installation position:vertical, falling
Temperature max.:40°C
Flow on overload Q4:7.9 m3/h
Continuous flow Q3:6.3 m3/h
Transitional flow rate Q2:0.063 m3/h
Min. flow Q1:0.039 m3/h
Measuring range:R160
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
92518 / PMKF-basic 32 10._150_1 1/4“
aquabasic® cold water meter
Nominal diameter:DN 32
With threaded ends 1 1/2"(for couplings 1 1/4")
Nominal pressure:PN 16 bar
Installation length:150 mm
Installation position:vertical, falling
Temperature max.:40°C
Flow on overload Q4:12.5 m3/h
Continuous flow Q3:10 m3/h
Transitional flow rate Q2:0.1 m3/h
Min. flow Q1:0.063 m3/h
Measuring range:R160
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
92521 / PMKF-basic 40 16._200_1 1/2“
aquabasic® cold water meter
Nominal diameter:DN 40
With threaded ends 2"(for couplings 1 1/2")
Nominal pressure:PN 16 bar
Installation length:200 mm
Installation position:vertical, falling
Temperature max.:40°C
Flow on overload Q4:20 m3/h
Continuous flow Q3:16 m3/h
Transitional flow rate Q2:0.256 m3/h
Min. flow Q1:0.16 m3/h
Measuring range:R100
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
aquabasic® PMKS 20 - 40
92508 / PMKS-basic 20 4.0_105_3/4“aquabasic® cold water meter
Nominal diameter:DN 20
With threaded ends 1"(for couplings 3/4")
Nominal pressure:PN 16 bar
Installation length:105 mm
Installation position:vertical, upstream
Temperature max.:40°C
Flow on overload Q4:5 m3/h
Continuous flow Q3:4 m3/h
Transitional flow rate Q2:0.04 m3/h
Min. flow Q1:0.025 m3/h
Measuring range:R160
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
92514 / PMKS-basic 25 6.3_150_1“
aquabasic® cold water meter
Nominal diameter:DN 25
With threaded ends 1 1/4"(for couplings 1 1/2")
Nominal pressure:PN 16 bar
Installation length:150 mm
Installation position:vertical, upstream
Temperature max.:40°C
Flow on overload Q4:7.9 m3/h
Continuous flow Q3:6.3 m3/h
Transitional flow rate Q2:0.063 m3/h
Min. flow Q1:0.039 m3/h
Measuring range:R160
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
92519 / PMKS-basic 32 10._150_1 1/4“
aquabasic® cold water meter
Nominal diameter:DN 32
With threaded ends 1 1/2"(for couplings 1 1/4")
Nominal pressure:PN 16 bar
Installation length:150 mm
Installation position:vertical, upstream
Temperature max.:40°C
Flow on overload Q4:12.5 m3/h
Continuous flow Q3:10 m3/h
Transitional flow rate Q2:0.1 m3/h
Min. flow Q1:0.063 m3/h
Measuring range:R160
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
92522 / PMKS-basic 40 16._200_1 1/2“
aquabasic® cold water meter
Nominal diameter:DN 40
With threaded ends 2"(for couplings 1 1/2")
Nominal pressure:PN 16 bar
Installation length:200 mm
Installation position:vertical, upstream
Temperature max.:40°C
Flow on overload Q4:20 m3/h
Continuous flow Q3:16 m3/h
Transitional flow rate Q2:0.256 m3/h
Min. flow Q1:0.16 m3/h
Measuring range:R100
Smallest readable value:0.1 l
Registration capacity:100000 m3
Measuring principle:Vane wheel
ast_aquabasic-pmkfs_e.doc09.20101/4