WP4341 N2 BOOSTER DATA SHEET

5800 PSIG

WP4341Nitrogen Booster Data Sheet – 5800 PSIG
Operating Pressure
(Flow Rate is Calculated in Free Air Delivery
Inlet pressure regulated down to ~ 0 psig) / Speed / UNITS
1450 rpm
(50 Hz)
3000 PSIG / 34.6 / SCFM
26.1 / HP
4500 PSIG / 33.0 / SCFM
25.7 / HP
5800 PSIG / 31.4 / SCFM
28.5 / HP
Technical Specifications / Motor rating / 30 / HP
Current @ 380 Volts / 41 / Amps
Weight of block and motor / 1400 / Pounds
Noise level @ 3 ft / 87 / dB(A)
Heat dissipation / 81,500 / Btu/hr
Cooling air needed / 2,200 / CFM
Residual oil content at gas outlet (without filtration) / < 3 / mg/m3
Delta temperature (gas oultet vs. ambient) / 18 / °F
Operational ambient temperature range / 40-130 / °F
Operating pressure range / 1670-5800 / psig
Oil sump capacity / 11.1 / Quarts
Dimensions of block and motor (L x W x H) / 55 X 37 X 36 / Inches
Cooling method / Air-Cooled
Drive type / Direct Drive
Stages/Cylinders / 4/4

*All data is with 5 % tolerance and is related to ambient conditions of 68 ° F and 14.7 PSIA.

Package Includes:

  • Feed tank run-permissive sensor (supplied loose)
  • Inlet Buffer Tank and Regulator Assembly
  • Intercoolers and aftercooler
  • Oil and water separators after the 1st, 2nd, 3rd ,and 4th stages
  • Safety valve after each stage
  • 1st, 2nd, 3rd ,and 4th stage pressure gauges
  • Solenoid valves (115 V / 50 Hz) for automatic drainage of the separators
  • Unloaded starting relief and automatic condensate drain system
  • Condensate demister to easily dispose of condensate drainage
  • Assembly of compressor and electric motor
  • Resilient mounts including drainage hoses and air/gas outlet hose
  • 380/3/50 electric motor with IP 55 (TEFC) protection
  • Non-return valve mounted to air/gas outlet hose
  • Low oil level shutdown switch
  • High air/gas temperature shutdown switch mounted at the air/gas outlet of the compressor
  • Final gas filtration for oil free delivery
  • Compressor control system (including motor starter) for starting/stopping the compressor, and monitoring the oil level, air/gas outlet temperature and outlet pressure of the compressor
  • Complete package wired and mounted on a skid
  • Air/gas pressure sensor for automatic start/stop (supplied loose)

Standard warranty is 15 months from date of shipment or 12 months after initial installation and start-up, whichever comes first. Ask your Sauer USA representative if your project requires an extended or alternative warranty period.

Optional equipment:

  • Final receiver packages with the necessary components supplied
  • Diesel motor driven
  • Modified for 60 Hz power supply
  • Modified for gas compression and higher inlet pressures (>4.5 psig)
  • Customized controls for user specified monitoring and operation
  • Sound dampening canopy
  • Weather resistant canopy
  • Complete package rated for installation in a hazardous location (Class 1 Division 2, or Class 1 Division 1)

Sauer Compressors USA custom engineers solutions for our customers. Please inquire about options you may require which are not listed.