TABLE OF CONTENTS

ITEM PAGE

TABLE OF CONTENTS 2,3

LIFERAFTS 4

LIFEBUOYS 5

PYROTECHNICS 5

ROCKET PARACHUTE FLARES 5

HAND HELD FLARES 5

BUOYANT SMOKE APPARATUS 6

RADAR TRANSPONDER (SART) 6

EPIRB 6

DAYLIGHT SIGNALING LAMP 6

PORTABLE RADIO APPARATUS 7

SELF-CONTAINED BREATHING APPARATUS 7

SCBA-APARE BOTTLES 7

LIFEJACKETS 8

RESCUE BOAT 8

FIXED CO2 SYSTEM 9

PORTABLE FIRE EXTINGUISHERS 9

FIRE HOSES, NOZZLES AND SPANNERS 10

FIREMAN’S OUTFIT 11

FIRE DAMPERS 12

INTERNATIONAL SHORE CONNECTION 12

FIRE PLAN 12

FIRE ALARMS 13

EMERGENCY FIRE PUMP / MAIN PUMP 13

ENDORSEMENT PAGE 14

Maintenance Procedure: Liferafts

Check: Cradle, Sealing, Ropes, Embarkation Ladder, Expiration date (12 months from last inspections), Visible Damage.

LIFERAFTS

/ NO. 1 / NO. 2
Capacity
Description
Makers Name
Serial Number
Location
Manufacturer Date
Service Date
Expire Date
Hydro Release

Maintenance Record Book Page 1 of 13

Maintenance Procedure: Lifebuoys

Check: No visible damage to out shielding, Man Rope, cradle, light expiration date (if applicable) smoke Signal.

LIFEBUOYS

/

Indicate Quantity and Condition Monthly Check

Location / Qty / Description / Manufacture
Or Exp. Date / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.
Lifebuoys with light and smoke signals capable of quick release from the bridge
Lifebuoys with self - igniting lights
Lifebuoys with 27.5 m (15 fms) buoyant
Life line
Lifebuoys with lifeline and self igniting lights (used for pilot)

TOTAL

Maintenance Procedure: Pyrotechnics

Check: Store location to be dry. Expiration Date.

ROCKETS AND SIGNALS

/

Indicate Quantity and Condition Monthly Check

Description / Location / Qty / Maker / Expire Date / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.
Line throwing apparatus with rockets and lines

PARACHUTE DISTRESS SIGNALS

HAND FLARES

BUOYANT SMOKE SIGNAL

Maintenance Record Book Page 1 of 13

Maintenance Procedure: Radar Transponders

Check for expiration date of Battery and follow test procedure posted on device.

RADAR TRANSPONDER

/

Indicate Quantity and Condition Monthly Check

Qty / Location / Maker / Expire Date / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: EPIRB

Check for expiration date of Battery and Hydrostatic Release, Test as per Manufacturer’s Instructions.

EPIRB

/

Indicate Condition Monthly Check

Qty / Location / Maker / Expire Date / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Signaling Lamp

Check operation. Check emergency source if provided.

DAYLIGHT SIGNALING LAMP

/

Monthly Check

Qty / Location / Maker / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Emergency Radio

Check operation of VHF. Check Expiration of Battery, or Recharge.

PORTABLE RADIO APPARATUS

/

Monthly Check

Qty / Location / Maker / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Fireman’s Outfit

Check outfit for damage. Check that outfit is complete with Ax, Lifeline, Flashlight, Light, Boots.

FIREMAN’S OUTFIT

/

Monthly Check

Qty / Description / Location / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: SCBA

Check condition of Mask, Visor, Hoses and gauges. Check bottle pressure min 90%. Check Service Dates.

SOLAS – SCBA 30 minutes

/

Monthly Check

No / Location / Expire Date / Rated Pressure / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: SCBA Spare Bottles

Check condition of bottle (pitting, damaged valves, fittings). Connect test gauge and test pressure (min 90% full).

SPARE BOTTLES

/

Monthly Check

No / Location / Expire Date / Rated Pressure / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Life Jackets

Check condition of outer material for damage. Check straps whistle and light (expirations Date). Check that ship’s name and home port are legible.

LIFE JACKETS /

Monthly Check

Location
(Indicate Storage Boxes Only) / Qty / Whistle
Whistle / Light Expire
Date / Jan. / Feb. / Mar. / Apr. / May. / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Rescue Boat

Check condition of Hull and Markings; check air pressure fuel level and equipment. Run engine (connect cooling water).

RESCUE BOAT

/

Monthly Check

No / Location / Expire Date / Rated Pressure / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Portable Extinguishers

Check that location matches fire plan. Check pressure if indicator is fitted. Turn powder extinguishers and shake powder loose.

PORTABLE FIRE EXTINGUISHERS /

Monthly Check

No / Location / Type / Capacity / Expire Date / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Fixed CO2 System

Visually check nozzles, pipes, cables, alarm, etc. Check service date (max 2 years)

CO2 Systems

/

Monthly Check

Location / Capacity / Location of Control Valve / Date Pressure Tested / System Service / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Fire Hoses

Inspect fire hoses for damage. Check couplings for damage and condition of gasket.

FIRE HOSES /

Monthly Check

Box. No / Location / Type / Nozzle / Spanner / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Fire Dampers

Check all fire dampers for proper functioning. Check fire dampers for damage.

FIRE DAMPERS

/

Monthly Check

Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.
Cargo Holds
Engine Room
Accommodation

Maintenance Procedure: InternationalShore Connection

Check for distortion or corrosion. Check all bolts and gasket are in place.

InternationalShore Connection: Location

/

Monthly Check

Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.

Maintenance Procedure: Fire Plan

Check for legibility and if up-to-date. Obtain Flag-state endorsement for any changes or modifications. Also, check watertight container

Fire Plan: Location

/

Monthly Check

Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.
Permanently Posted on Bulkhead:
In Waterproof Container (P)
In Waterproof Container (S)

Maintenance Record Book Page 1 of 13

Maintenance Procedure: Fire Alarm System

Check at least one manually operated and one smoke alarm in each section every month.

FIRE / DAMPERS ALARMS

/

Monthly Check

Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.
Cargo Holds
Engine Room
Accommodation

Maintenance Procedure: Main Fire Pump / Emergency Fire Pump.

Start pump and connect two hoses, one at aft deck, other on forecastle. Water pressure to give stream of at least 10 mtr.

Follow manufacturer’ instructions on periodic maintenance schedule

Monthly Check

Location / Jan. / Feb. / Mar. / Apr. / May / Jun. / Jul. / Aug / Sep. / Oct. / Nov. / Dec.
Main Fire Pump / Engine Room
Emergency Fire Pump

Maintenance Record Book Page 1 of 13

Month / Officer Name / Signature / Master Name / Signature / Remarks
January
February
March
April
May
June
July
August
September
October
November
December