11 12 00 Parking Control Equipment

11 12 33 Parking Gates

11 12 33.13 Lift Arm Parking Gates

34 52 00 Vehicle Fare Collection

34 52 33 Vehicle Fare Gates

34 71 00 Roadway Construction

34 71 13.19 Vehicle Traffic Barriers

34 75 00 Roadway Equipment

34 75 13.13 Active Vehicle Barriers

34 48 00 Bridge Signaling and Control Equipment

34 48 16 Operating Bridge Control Equipment

Display hidden notes to specifier. (Don't know how? Click Here)

** NOTE TO SPECIFIER ** Magnetic Automation Corp; Parking control equipment products.

.

This section is based on the products of Magnetic Automation Corp, which is located at:

3160 Murrell Rd.

Rockledge, FL 32955

Phone: (321) 635-8585

Fax: (321) 635-9449

Web Site:

Email:

[click Here] for additional information.

Welcome to Magnetic Automation Corp, a premier solutions provider for parking and entrance control applications across the globe.

Our product performance is unsurpassed and our design flexibility picks up where others leave off. We have been going strong for over 70 years and we continue to expand with a sound financial backing.

Our dealer/distributor and system integration partners are some of the top names in their respective industries. Magnetic's products, which include vehicle barrier gate operators, turnstiles, pedestrian barriers, parking control hardware and other related equipment are used in high profile, high throughput locations around the world. Examples include Government sites, toll roads, airports, seaports, rental car facilities, mass transit sites and other related applications.

Furthermore, besides providing the best products possible, we take great pride in our customer service and doing the old fashioned way; we earn it.

PART 1 GENERAL

1.1SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

  1. Toll Gates.Toll HiSpeed
  2. Toll Gates. Toll Pro
  3. Toll Gates.Toll
  4. High Speed Parking Gates in high housing Parking Pro M
  5. High Speed Parking GatesParking Pro
  6. General Purpose Access Vehicle Gates in high housing up to 20 feetAccess Pro H
  7. General Purpose Access Vehicle Gates up to 20 feetAccess Pro L
  8. Wide Lane Vehicle Gates.Access XL
  9. Wide Lane Vehicle Gates. Access XXL

1.2RELATED SECTIONS(CSI schedule)

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

  1. Section 31 23 00 - Excavation and Fill.
  1. Section 33 06 40.13 – Storm Drainage.
  1. Section 03 10 00 – Concrete Forming and Accessories.
  1. Section 32 31 00 - Fences and Gates
  1. Section 0330 00 – Cast-In-Place Concrete.
  1. Section 28 13 00 - Access Control.
  1. Section 26 05 00 - Common Work Results for Electrical

1.3REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

  1. ANSI/UL 325 - Door, Drapery, Gate, Louver, and Window Operators and Systems.
  1. CAN/CSA-C22.2 No. 247-1992 - Operators and Systems of Doors, Gates, Draperies and Louvres.

1.4DESIGN / PERFORMANCE REQUIREMENTS

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

  1. Gates conform to the following UL Classifications.
  2. Meets ANSI/UL 325, UL Category FDDR - Door, Drapery, Gate, Louver and Window Operators and Systems Certified.
  3. Meets CAN/CSA-C22.2 No. 247-1992, UL Category FDDR7 - Door, Drapery, Gate, Louver and Window Operators and Systems (Certified for Canada).
  4. Boom fixture designed to withstand winds of up to a maximum of force 10 on the Beaufort scale (10.44 Lb/sqft; 500 N/m2).

1.5SUBMITTALS

  1. Submit under provisions of Section 01 32 19.
  1. Product Data: Manufacturer's data sheets on each product to be used, including:
  2. Preparation instructions and recommendations.
  3. Storage and handling requirements and recommendations.
  4. Operation, installation, and maintenance manuals including wiring diagrams.
  1. Shop Drawings: Submit shop drawings showing layout, profiles, and product components, including anchorage, edge conditions, and accessories. Include risers, layouts, and special wiring diagrams.
  1. Manufacturer's Certificates: Certify products meet or exceed specified requirements.
  1. Closeout Submittals: Provide manufacturer’s maintenance instructions that include recommendations for periodic checking and periodic cleaning and maintenance of all components.

1.6QUALITY ASSURANCE

  1. Manufacturer Qualifications: Manufacturer with minimum of 10 years experience systems specified.
  1. Installer Qualifications:Factory authorized Installer specifically trained in gate operation systems of the type found within this section with documented maintenance and repair service availability for emergency conditions.
  1. Provide quarterly maintenance for one year following Substantial Completion of the Project.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

  1. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
  2. Finish areas designated by Architect.
  3. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
  4. Refinish mock-up area as required to produce acceptable work.

1.7DELIVERY, STORAGE, AND HANDLING

  1. Store products in manufacturer's unopened packaging with labels intact until ready for installation.
  1. Schedule delivery of parking control equipment so that spaces are sufficiently complete that operators can be installed upon delivery.

1.8SEQUENCING

  1. Ensure that locating templates and other information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.
  1. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

1.9PROJECT CONDITIONS

  1. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.10WARRANTY

  1. Manufacturer's standard two years or 2 million cycles warranty for vehicle gates.

PART 2 PRODUCTS

2.1MANUFACTURERS

  1. Acceptable Manufacturer: Magnetic AutoControl; 3160 Murrell Rd., Rockledge, FL 32955. Phone: (321) 635-8585. Fax: (321) 635-9449. Web Site: Email: ,

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

  1. Substitutions: Not permitted.
  1. Requests for substitutions will be considered in accordance with provisions of Section 00 26 00.

** NOTE TO SPECIFIER ** Select the Gate(s) required from the following paragraphs and delete those not required. If multiple gates are required indicate the quantity and configuration on the Drawings and/or the Schedule at the end of this section.

2.2VEHICLE GATES

  1. Toll HiSpeed, High Speed Barrier Gate:
  2. Maximum Arm Length 10 Feet.
  3. 0.6 or 0.86 or 1.2 Seconds,Adjustable Open / Close Time.
  4. Ambient Temperature range minus 30 degrees C to plus 55 degrees C (minus 22 degrees F to 131 degrees F).
  5. Wind force 10 Bft (Beaufort).
  6. Arm Location:

** NOTE TO SPECIFIER ** Select one of the following two paragraphs, delete the one not required.

  1. Left hand.
  2. Right hand.
  1. Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.

** NOTE TO SPECIFIER ** Delete gate arm not required and refer to maximum arm length restrictions for the barrier chosen.

  1. 10 foot round swing-away MicroBoom arm.
  2. 10 foot round foam covered swing-away MicroBoom arm.
  3. Trim to length indicated.
  1. Nominal operating power:85 to 264VAC, 50 or 60 Hz, 320 Watts.
  2. Housing: 1115 mm (43.9 inches) tall, 315 mm (12.4 inches) wide, 360 mm (14.2 inches) deep and 875 mm (34.44 inches) height to center of arm. Control units mounted to zinc plated sheet steel panel. All components are accessible through maintenance door and removable top cover. All programing is done by removing the hood while standing up.
  3. Aluminum extruded housing frame chromatized and powder coated.
  4. Provided with one lockable service door to provide access to the power switch, controller, receptacle, and control wiring for service.
  5. Front panel is removable without hand tools, and rear panel requires 3mm Allen wrench for removal to perform maintenance.
  6. Housing fits onto frame pieces to form a weather tight (IP54) enclosure.
  7. Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
  8. Stainless steel base frame.
  9. Color: Front and rear access panels similar to RAL7021 (black grey)

** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.

  1. Color: Similar to RAL 2000 Orange. (RC0**0*
  2. Color: Similar to RAL 9010 White. (RC0**4*)
  3. Color: Custom color as selected by the Architect.
  1. Flange Type:

** NOTE TO SPECIFIER ** Delete flange type not required, confirm flange and boom type match.

  1. Round swing away Flange.
  2. Flange for swing-away foam covered boom.
  3. Wood boom flange (boom by others 1” x 3” dimension in flange).
  4. Swing away with Automatic Return for foam covered boom.
  1. Drive Unit: MHTM Microdrive,100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system providesa MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
  2. Controller: MGC-PRO integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced opening or closing speed.
  3. Plug in module Dual channel vehicle loop detector.
  4. Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
  5. Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
  6. Output relays: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
  7. Most I/O parameters are adjustable. I/O functions are re-assignable in the field.
  8. Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
  9. 5 slots for plug in modules.
  10. Service mode – allows raising and lowing of gate via integrated push buttons
  11. Safety Device: Provide with the following device.

** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.

  1. Photoelectric beams.

1)Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.

  1. Safety loop.

1)Current consumption: 50 mA

2)Number of loop detectors: 2

3)Inductance range: 70 to 500 µH

4)Number of induction loop sensitivity levels: 10

5)Response sensitivity induction loop selectable: 0.01 to 2.0 percent

  1. Features:
  2. Low power consumption
  3. Direct drive operation
  4. Modular construction.
  5. IP 54 rated enclosure
  6. Built-in position sensors with no limit switches providing arm position status and self-learning control to optimize braking and eliminate boom arm bouncing, sagging, or rotating out of position.
  7. Programmable controller for common lane configurations.
  8. Most Input and output parameters can be easily changed.
  9. Input and output functions are re-assignable in the field.
  10. Control electronics can be reached and programmed from the top.
  11. MTBF greater than 2,000,000 cycles.
  12. Tested to ten million cycles.

** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.

  1. Optional Equipment:
  2. Dual channel vehicle loop detector.
  3. Contact for release of barrier arm.
  4. Additional heater for extremely cold environments.
  5. Ethernet module that allows for complete gate status, control query
    of can bus protocol and reconfiguration from a remote location.
  6. RS485 module.
  7. Inductive limit switch set.
  8. Key switch permanent open / momentary closed.
  9. Key switch momentary open / momentary closed.
  10. Key switches can be keyed alike of keyed differently.
  11. Mounting plate for customer specific ad-ons.
  12. Service module.
  13. Plug in Radio receiver module 433 MHz.
  14. One, two and four button radio transmitters.
  15. Desk panel for one, two, three or four gates.
  16. Hood mount Xenon flashing orange light.
  17. Hood mount LED flashing orange light.
  18. Hood mount permanent on red light (configurable lead time).
  19. Mast or pole mounting kit for traffic lights or AVI readers.
  20. Hood contact switch
  21. Counting module
  1. TollPro,High Speed Barrier Gate:
  2. Maximum Arm Length 10 Feet.
  3. 0.9 or 1.3 or 1.8 Seconds,AdjustableOpen / Close Time.
  4. Ambient Temperature range minus 30 degrees C to plus 55 degrees C (minus 22 degrees F to 135 degrees F).
  5. Wind force 10 Bft (Beaufort).
  6. Arm Location:

** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.

  1. Left hand.
  2. Right hand.
  1. Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.

** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.

  1. 8 foot octagonal MicroBoom arm with slide-in foam on bottom.
  2. 8 foot octagonal swing-away arm with slide-in foam on bottom.
  3. 10 foot round swing-away MicroBoom arm.
  4. 10 foot round foam covered swing-away MicroBoom arm.
  5. Trim to length indicated.
  1. Nominal operating power:85 to 264VAC, 50 or 60 Hz, 95 Watts.
  2. Housing: 1115 mm (43.9 inches) tall, 315 mm (12.4 inches) wide, 360 mm (14.2 inches) deep and 875 mm (34.44 inches) height to center of arm. Control units mounted to zinc plated sheet steel panel. All components are accessible through maintenance door and removable top cover. All programing is done by removing the hood while standing up.
  3. Aluminum extruded housing frame chromatized and powder coated.
  4. Provided with one lockable service door to provide access to the power switch, controller, receptacle and control wiring for service.
  5. Front panel is removable without hand tools, and rear panel requires 3mm Allen wrench for removal to perform maintenance.
  6. Housing fits onto frame pieces to form a weather tight (IP54) enclosure.
  7. Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
  8. Stainless steel base frame.

** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.

  1. Color: Front and rear access panels similar to RAL7021 (black grey)
  2. Color: Similar to RAL 2000 Orange. (RC0**0*
  3. Color: Similar to RAL 9010 White. (RC0**4*)
  4. Color: Custom color as selected by the Architect.
  1. Flange Type:

** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.

  1. Round boom swing away flange.
  2. Flange for swing-away foam covered boom.
  3. Octagonal Boom fixed flange
  4. Octagonal Boom swing-away flange.
  5. Wood boom flange (boom by others 1” x 3” dimension in flange).
  6. Swing away with Automatic Return for foam covered boom.
  1. Drive Unit: MHTM Microdrive,100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system providesa MTBF in excess of 2 million cycles operation.Microdrive with combined motor control and gearing tested for 10 million cycles.
  2. Controller: MGC-PRO integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced opening or closing speed. .
  3. Plug in module Dual channel vehicle loop detector.
  4. Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
  5. Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
  6. Output relays: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
  7. Most I/O parameters are adjustable. I/O functions are re-assignable in the field.
  8. Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
  9. 5 slots for plug in modules.
  10. Service mode – allows raising and lowing of gate via integrated push buttons
  11. Safety Device: Provide with the following device.

** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.

  1. Photoelectric beams.

1)Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.

  1. Safety loop.

1)Current consumption: 50 mA

2)Number of loop detectors: 2

3)Inductance range: 70 to 500 µH

4)Number of induction loop sensitivity levels: 10

5)Response sensitivity induction loop selectable: 0.01 to 2.0 percent

  1. Features:
  2. Low power consumption
  3. Direct drive operation
  4. Modular construction.
  5. IP 54 rated enclosure
  6. Built-in position sensors with no limit switches providing arm position status and self-learning control to optimize braking and eliminate boom arm bouncing, sagging, or rotating out of position.
  7. Programmable controller for common lane configurations.
  8. Most Input and output parameters can be easily changed.
  9. Input and output functions are re-assignable in the field.
  10. Control electronics can be reached and programmed from the top.
  11. Convenience Receptacle.
  12. MTBF greater than 2,000,000 cycles.
  13. Tested to ten million cycles.

** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.