SUBDIVISIONAL CONSTRUCTION STANDARDS

[CoHB1]

APPLICABLE CONSTRUCTION STANDARD / CITY OF HOBSONSBAY
CONSTRUCTION STANDARD / COMMENTS
ROAD REQUIREMENTS
ROAD RESERVE WIDTHS
Access Lane / 6 - 8 metres / Refer to VicCode for definitions
Access Place / 14 - 16 metres
Access Street / 16.0 metres
Collector Street / 20.0 metres
Trunk Collector / 20.5 - 24 metres
Industrial / 20 metres
ROAD PAVEMENTS WIDTHS
Access Lane / 5.0 - 5.5 metres face to face of kerb
Access Place / 5.0 - 5.5 metres face to face of kerb
Access Street (court) / 5.0 - 5.5 metres F/F but must provide adequate on street car parking on one side / Road widths of less than 7.5 metres do not allow through passage of vehicles if parking is permitted on both sides of the road pavement. Indented parking may be required.
Access Street (through street) / 7.3 metres face to face of kerb
Collector Street / 9 .7 - 10.2 metres face to face of kerb
Trunk Collector / 5.0 - 5.5 metres or 3.5metres in each carriageway of a dual carriageway
Industrial / 12.0 metres face to face
COURT BOWLS AND HAMMERHEADS
Residential Areas / 8.5 metres radius for court bowls which must allow for the turning of service vehicles. / Hammerheads are not favoured in residential areas because they limit on-street parking and may create problems with maneuvering.
Industrial / 12 metres radius for court bowls.
Other shapes will be judged on merit and turning templates. / Through roads are preferred.
PAVEMENT MAKEUP
Access Lane / 200mm concrete with one layer of F92 reinforcement on 75mm Class 3 FCR / Equivalent clay brick paving is acceptable
Access Place /Access Street
Base Layer
Intermediate Layer 1
Intermediate Layer 2
Wearing Course
Concrete Pavement
Brick Pavement / 150 mm 2% CSFCR Class 3 or crushed concrete extending 300 mm behind back of kerb
180 mm FCR Class 2
35 mm size 14 Asphalt
25 mm size 10 Asphalt (delayed 12 months)
200mm thick concrete F92 reinforcement on 75mm Class 3 FCR
80mm Clay brick on 25mm sand bedding
85mm primed layer Class 2 F.C.R.
165mm 2% cement stabilised Class 3 F.C.R. / The majority of road failures in the HobsonsBay area result from earth movement (swelling or shrinkage) vehicle loading criteria being less significant. This earth movement is familiar in the highly reactive balsaltic clays of the Williamstown, Newport and Altona North areas and the effect lessens towards the west. Current pavement profiles are effective and will be maintained as the AustRoads guidelines do not address this problem. A CSFCR layer is necessary to prevent the fine clay particles from the subgrade migrating through the pavement. This sealing of the base has been recommended by independent geological consultants.
APPLICABLE CONSTRUCTION STANDARD / CITY OF HOBSONSBAY
CONSTRUCTION STANDARD / COMMENTS
Collector / Trunk Collector
Base Layer
Intermediate Layer 1
Intermediate Layer 2
Wearing Course / 200 mm 2% C.S.F.C.R. Class 3 extending 500 mm behind kerb.
200 mm FCR Class 2
35 mm size 14 Asphalt
25 mm size 10 Asphalt
Industrial / Deep lift asphalt designed for prevailing conditions / Consideration of Concrete or Conventional Pavements designed for prevailing conditions.
CONCRETE WORKS DETAILS
FOOTPATHS
Access Lane
Access Place / Access Street / 1.5 metre wide , 100 mm thick concrete with F42 reinforcement on 75 mm thick Class 3 F.C.R. base on both sides of street. / May permit 1.2metre wide footpath in courts.
In heritage/conservation areas footpath to be 25mm asphalt on 75mm Class 2 FCR.
Collector / Trunk Collector / 1.5 metre wide ,100 mm thick concrete with F42 reinforcement on 75 mm thick Class 3 base on both sides of street / In heritage/conservation areas footpath shall be 25mm asphalt on 75mm Class 2 FCR.
Industrial / Not Required
PRAM CROSSING
Construction Standards / 100 mm thick concrete with F42 reinforcement on 75 mm class 3 F.C.R. - no bullnose / In heritage/conservation areas concrete to be
pigmented “Bay Ferrox” (Colour Black 318) - 4% pigment/cement ratio.
KERB PROFILES
Access Lane / For historical reasons, kerb profiles will vary depending on the location within the City and these standards are currently being maintained particularly with barrier kerbing. / A standard mountable kerb profile may be established over time.
Access Place / Access Street / As Above
Collector / Trunk Collector / As Above
Industrial / As Above
Intersection Treatments / Vicroads semi-mountable profiles
SM1, SM2, SM3 or Barrier Kerbing / Bluestone work required in some residential areas of Williamstown
VEHICLE CROSSINGS
Residential Areas at subdivisional stage / Required for all allotments.
2.8 metres min width,
150 mm thick concrete with F62 reinforcement on 75 mm thick Class 3 F.C.R. / In heritage/conservation areas concrete to be
pigmented “Bay Ferrox” (Colour Black 318) - 4% pigment/cement ratio.
Industrial areas / 3m minimum, 7m maximum width
225 mm thick concrete with twin F82 reinforcement on 75 mm thick base of Class 3 FCR / Not required at subdivisional stage.
GRADES
Crossfall on road pavement / General minimum 1 in 40
Absolute minimum 1 in 50
Desirable 1 in 36
Longitudinal Fall in Kerb and Channel / General minimum 1 in 200
Absolute minimum 1 in 285
Absolute minimum around court bowls and kerb returns 1 in 200
Crossfall footpath / General grade 1 in 50
Crossfall nature strip / General grade 1 in 33
Crossfall allotment / General minimum 1 in 150
Grade Change at vehicle crossing / 12% maximum / As per Vic Roads
APPLICABLE CONSTRUCTION STANDARD / CITY OF HOBSONSBAY
CONSTRUCTION STANDARD / COMMENTS
SERVICES PROVISION
ALIGNMENTS
Gas / In accordance with Streetworks Code. / New code promotes shared trenching.
Electricity / In accordance with Streetworks Code Underground supply mandatory. / New code promotes shared trenching.
Telecom / In accordance with Streetworks Code. / New code promotes shared trenching.
Water / In accordance with Streetworks Code. / New code promotes shared trenching.
CONDUITS
Residential Area / 50 mm Class 12 PVC conduits provided for water, gas (and telecommunications if required). Minimum cover below boxing 100 mm extending 300 mm past kerb, 450 mm below footpath, generally centrally located along frontage or as marked on drawings / Marked on face of kerb and channel and footpath with 75 mm high letters.
Industrial Areas / 150 mm class 12 PVC conduits provided for water and gas for each property. / Marked on face of kerb and channel and footpath with 75 mm high letters.
EASEMENTS / Minimum width for Council drain 1.80 metre. / Required for all public drains and sewers on properties.
SERVICES RESPONSIBILITY
Water and sewerage / City West Water
Gas / Ikon or Westar
Telecommunications / Telstra or Optus
Electricity / AGL or Powercor
Drainage / Melbourne Water or Council
DRAINAGE
RETURN PERIODS
Residential / 1 in 5 years
Industrial / 1 in 10 years
Commercial / 1 in 20 years
Multi unit sites (internal within boundaries) / 1 in 20 years
Overflow provision in subdivision (overland) / 1 in 100 years
COEFFICIENT OF RUN OFF
Residential / 0.45
Industrial / 0.9
Commercial / 0.9
Pervious area / 0.3
Impervious area / 0.9
RAINFALL INTENSITY / As per Bureau of Meteorology Chart for the Hobsons Bay City Council area.
TIME OF CONCENTRATION / Roof time 5 minutes
Pipe time 2 minutes minimum.
Minimum time 7 minutes
PIPE REQUIREMENTS
Pipe type / Concrete or FCR with RRJ appropriate class in accordance with Australian Standard
Min sizes / 150 mm if sealed pits
225 mm if unsealed pit
300 mm under road
Min grades / 150 mm 1 in 150
225 mm 1 in 200
300 mm 1 in 250 / above 300 mm grade determined by Min velocity of 0.6 m/s
APPLICABLE CONSTRUCTION STANDARD / CITY OF HOBSONSBAY
CONSTRUCTION STANDARD / COMMENTS
Pipe velocity / Minimum 0.6 m/s
Maximum 6.0 m/s
BACKFILLING REQUIREMENTS
Easements / 150 mm above and at sides, 75 mm below with Class 3 material / Location of drains greater than 300mm diameter should be avoided within property easements.
Behind kerb and channel / As above but Class 3 material to base of kerb and channel
Road crossings / As above but Class 3 material to base of road formation
PIT REQUIREMENTS
Spacing / Max 100 metres
Desirable 50 metres
Size
Junction Pits / VicRoads Standard
but with 150 mm thick walls unreinforced / 750 mm x 750 mm for depths to 1200 mm,
750 mm x 1000 mm for depths 1200 mm to 2400 mm
Side Entry Pits / VicRoads Standard
1000 mm x 750 mm. / Lid and frame to be Gatic type - no lintel. Use heavy duty lid and frame in industrial areas.
Step Irons and wall reinforcement / VicRoads Standard / Required for depths over 1200 mm, ladders required for depths over 2400 mm
Lids (except SEPs) / VicRoads Standard
Concrete reinforced. / Areas under road traffic use heavy duty “Gatic” or approved equivalent
Footpath areas use light duty “Gatic” or approved equivalent
Corbelling (from large pit to smaller opening) / VicRoads requirement
750 mm x 750 mm min
Pit in Sump location with no overland flow relief / Double side entry pit
HOUSE DRAINS OR PROPERTY INLETS
WHERE REQUIRED
Residential Area / Points connected to underground drainage required for every allotment
Industrial Area / Points connected to underground drainage. / Inlet size based on area of allotment
DEPTH
Residential / Minimum cover generally 450 mm.
Absolute minimum 300 mm / Sufficient to drain the allotment from the furthest point at a minimum grade of 1 in 100.
Industrial / Minimum depth 1200 mm / Sufficient to drain the allotment.
CONSTRUCTION REQUIREMENTS
House drains / 100 mm minimum Class 12 PVC, "Corflow", FRC or concrete.
Grade 1 in 50 minimum / Location to be marked with “O” on footpath and kerb and channel
Saddle connection to pipe permitted but connection to pit, where available, is preferred
Property Inlets
Residential / As per standard drawing / Locate clear of driveways.
Property Inlets
Industrial Areas / 225 mm minimum diameter pipe / Connect to appropriate sized pit in main pipeline.
AGRICULTURAL DRAINS
Location / Behind all kerb and channel
Construction / As per standard drawing
APPLICABLE CONSTRUCTION STANDARD / CITY OF HOBSONSBAY
CONSTRUCTION STANDARD / COMMENTS
ON STREET CAR PARKING
Indented Parking in Access Streets / 25mm size 7 asphalt
35mm size 14 asphalt
200mm Class 2 F.C.R. or
150mm pattern pave concrete on 75mm Class 3 F.C.R. / Provide where road pavement width is less than 7.3 metres face to face of kerb
Concrete preferred for construction finish.
MISCELLANEOUS
Street Signs / to Council requirements
Traffic Control signs / In accordance with the Road Traffic Regulations
Line Marking and RRM's / As appropriate
Permanent Survey Marks / As required
Filling on allotments / 95 % Australian Standard Maximum Dry Density in 150 mm (loose) layers
Root Barriers / Required at every nature strip tree location
Street Lighting / In accordance with AS 1158.1 - 1986
End of Stage treatment / Provide for drainage.
Construct end of pavement concrete edge protection.
Place “ROAD CLOSED” sign.
Plans & Specification / Initial check
Drainage catchment plan and computations for downstream drainage capacity and one set of plans and specification.
Construction.
Three copies design approved plans and one copy of specification. / One copy “as constructed” design plans on durable media and digital plan files in .dwg or dxf format required prior to issue of compliance.
Supply extra copy if return endorsed approved plan required.
PLANS CONSTRUCTION / Show lot numbers, lot size, extent and depth of cut and fill, easement locations, service locations, detail contoured intersection plans, traffic signage plans as well as general detailed technical information including longitudinal sections, cross sections, typical cross section, pavement details, landscaping plans, sprinkler systems, street furniture, TBM's, PSMs, pit schedules and existing and proposed allotment levels etc
PLANS SUBDIVISION / Registered plan

[CoHB2]

- 1 -

10/16/2018

Subdivisional Construction Standards.doc

[CoHB1]1

[CoHB2]1