How Do I – Test Magnetic Plugs in the system

Magnetic Plugs collect iron material (FE) from the oil as it passes. Magnetic plugs are removed from the oil sump during the oil change. They will typically be examined by the service technician performing the oil change, and an assessment made in terms of the condition. In certain cases, an image will be loaded to assist. Infotrak will only allow a maximum of 2 images for each magnetic plug.

The system now allows for two types of testing;

  1. When an Oil Sample is taken it allows for the image of the plug to be added to assist with interpretation
  2. When the oil is changed, the magnetic plug can be sent to the laboratory for analysis, and a replacement plug will be provided by the laboratory. The magnetic plug will then be treated like a filtergram with analysis being completed on both wear mechanisms and size of the particles. Images will be loaded to the system in exactly the same way as filtergram images. A separate test type needs to be created called magnetic plugs.

Changes made to the system are;

  1. Label Printing Screen

A panel has been added to capture the comments and images for Magnetic Plugs and Screens.

This screen allows the addition of the images for the different stages to enable users to add the data, and is accessible from the print label queue.

  1. Magnetic Plug Data entry screen

Please see screen shot below

The following popup screen can also be able to be opened from the

2.1.Label Printing Screen

2.2.Oil Main Analyse screen

2.3.Outstanding Samples screen

  1. Outstanding Print Labels

The magnetic plug screen can be viewed and edited or added in this screen

  1. Edit Interpretation Screen

Interpreters will be able to view the Magnetic Plug images and comments

  1. Oil images Screen

Adding Magnetic Plugs can be done through the oil images screen as well

  1. Oil Details Screen

Magnetic Plug Images can be seen in the details screen as follows:-