Postal AddressBuilding and PlumbingInternet

PO Box 159Ph: 07 3205 0555

Caboolture QLD

ABN:92 967 232 136

Applicant details:

Name:
Postal address:
Home number: / Mobile phone: / Work/Business phone:

Note: Contact numbers which you provide may be used to update council’s records.

Subject property information:

Street address:
Real property description: / Lot: / Plan:

Siting details: Site plans attached Photographs attached

Intended water supply: rainwater reticulated water supply

Estimated greywater volume (litres/day):
Land application area (required m2): / Land application area (available m2):

Assessment details:

Buffer distances:

Building footing and retaining wall footings

  • 2 metres for flat sites and where system is on down slope
  • 4 metres where system is on up slope

Property boundaries, public pedestrian or cycle paths or recreation areas

  • 2 metres for flat sites and where system is on down slope
  • 4 metres where system is on up slope

Household drainage, potable water lines, council sewer pipes and stormwater line

  • 1.5 metres

Swimming pools – in ground

  • 6 meters

Potable water tank – in ground

  • 15 meters

Is there sufficient land area available for land application systems: Yes No

Climate:

Are low temperatures expected – particularly below 15°c: Yes No

Is high rainfall likely to be a problem in this location: Yes No

Exposure:

Is the land application area exposed to ample sunlight and to prevailing winds: Yes No

Run-on seepage:

Does the land have high run-on and upslope seepage with no practical diversion: Yes No

Erosion potential:

Does the land show signs of high erosion eg. rills, mass movement/slope failure present: Yes No

Site drainage:

Does the land show visible signs of surface dampness, such as moisture-tolerant vegetation, (eg. bottle brush, paper bark trees, or ferns), seepages, soaks and springs: Yes No

Landfill:

Has the property been cut and filled, or sited on imported fill Yes No

Flood potential:

Land application area above 1 in / 20 year flood level
Land application area above 1 in / 100 year flood level
Electrical components above 1 in 100 year flood level

Slope:

0-10% 10-20% >20%

Groundwater:

Horizontal distance to groundwater well used for domestic water supply: / m
Bores in the area and their purpose:

Soil:

Depth to bedrock or hardpan:
Depth to high episodic or seasonal water table:

Types, characteristics, permeability:

Other matters: e.g. density of allotments within the area

Privacy statement

MoretonBay Regional Council is collecting your personal information for the purpose of assessing your application for installing a greywater diversion device. The collection of this information is authorised under the Plumbing and Drainage Act 2002. Your information will not be given to any other person or agency unless you have given us permission or we are required by law.

Page 1 of 2