SECTION 1259 00
SYSTEMS FURNITURE
PART 1 GENERAL
1.1 SECTION INCLUDES
- Systems Furniture
- Exterior wall panels.
- Interior wall panels.
- Suspended ceiling.
- Ceiling lighting.
- Corners and base.
- Door.
- Flooring.
- Interior furniture.
- RELATED SECTIONS
- Section 26 05 00 –Common Work Results for Electrical
- Section 09 00 00 – Finishes.
- SUBMITTALS
- Submit under provisions of Section 01 30 00 - Administrative Requirements.
- Product Data: Provide manufacturer's data sheets on each product to be used.
- Shop Drawings: Details of construction, including trim, face materials, colors, and dimensions. Include installation and maintenance instructions.
- Verification Samples: Submit samples of wall panel face material(s) to illustrate material, finish, and color of finished product specified.
- QUALITY ASSURANCE
- Manufacturer Qualifications: Minimum 10years experience in manufacture of architectural surface materials and fabrication of interiors.
- Installer Qualifications: Minimum 3 years experienceinstallingsimilar products.
- DELIVERY, STORAGE, AND HANDLING
- Deliver materials to installation site in manufacturer's original packaging. Store in dry, secure location, protected against direct sunlight and excessive heat. Protect finished surfaces.
- PROJECT CONDITIONS
- Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's limits.
- WARRANTY
- Warranty: Provide manufacturer's three-year warranty against defects and workmanship, from the date of material shipment.
PART 2 PRODUCTS
2.1 MANUFACTURERS
- Acceptable Manufacturer: SnapCab, which is headquartered at: 175 Titus Ave.; Warrington, PA 18976; Toll Free Tel: 888-766-7834; Email: ; Web:
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
- Substitutions: Not permitted.
- Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
- STAND-ALONE QUIET SPACES
- Portable Pod:Finished removable wall panels with rabbeted joints, 1/8 inch black shadow lines set into surface, attached to heavy gauge aluminum structure. Interior suspended ceiling with motion activated lighting and ventilation, tempered glass front wall and door, removable carpet floor, and interior power bar. Mounted on high-load phenolic casters for easy relocation.
** NOTE TO SPECIFIER ** Delete model(s) not required.
- Model: SnapCab Pod S (capacity 1-2 people). Qty. ___
Exterior Dimensions: 46” x 46”x 91” H
Interior Dimensions: 40” x 40”x 78” H
- Model: SnapCab Pod M (capacity 2-4 people). Qty. ___
Exterior Dimensions: 53” x 77” x 91” H
Interior Dimensions: 47” x 71” x 78” H
- Model: SnapCab Pod L (capacity 4-6 people). Qty. ___
Exterior Dimensions: 77” x 77” x 91” H
Interior Dimensions: 71” x 71” x 78” H
2.3 MATERIALS
- Structure
- Heavy gauge proprietary aluminum extruded channel. Mounted on high-load phenolic casters.
- Wall Panels:
- Removable wall panels with rabbeted joints and 1/8 inch (3 mm) black shadow lines set into surface.
- Wall Panel Face Materials
** NOTE TO SPECIFIER ** Delete surface types not required.
- Laminate: Standard finish, 0.039 inch (0.99 mm) minimum thickness Horizontal Grade Postforming Laminate conforming to NEMA standard HGF, with Class B or better fire rating when laminated to fire-rated particle board as per ASTM E 84.
- Upper interior panels color/finish:
1) Standard Laminate: White, gloss.
2) Expanded Laminate: (Enter manufacturer name, color, and finish).
- Lower interior panels color/finish:
1) Standard Laminate: White, gloss.
2) Expanded Laminate: (Enter manufacturer name, color, and finish).
- Exterior panels color/finish:
1) Standard Laminate: White, gloss.
2) Expanded Laminate: (Enter manufacturer name, color, and finish).
- Corning® Gorilla® Glass: .08 inch (2 mm) minimum thickness Gorilla® Glass, Class A fire rated as per ASME E 84, as manufactured by Corning, Inc.
- Upper back wall interior panels, color adhered to back face of Gorilla® Glass:
1)Solid Color: Bright White, gloss
- Panoramic Corning® Gorilla® Glass: .08 inch (2 mm) minimum thickness Gorilla® Glass, Class A fire rated as per ASME E 84, as manufactured by Corning, Inc.
- Upper interior panels,image adhered to back face of Gorilla® Glass:
1)Gigapixel Panoramic:
a) Loki Point
b) Aspiring Assiniboine
c) Rundle and Jack
d) Stanley Sunset
e) Ethereal Forest
f) Forever Fields
g)Golden Glow
h)Sizzling Sunset
- Interior Suspended Ceiling:
- Ceiling acoustical panels (medium grey) inserted into heavy-duty 1.5inch (38 mm) T aluminum frame (Silver, satin).
NOTE TO SPECIFIER ** Delete lights not required.
- Motion activated ceiling lights:
- Dimmable downlights
- Optional: Dimmable indirect LED lights along back and side walls
- Motion activated ventilation:
- 57 CFM low voltage fans (Pod S)
- 108 CFM low voltage fans (Pod M or Pod L)
- Interior power bar:
- Three 110VACoutlets.
- Two USB charging ports.
- Indirect Corners and base:
- Anodized aluminum (Silver, satin).
- Front wall:3/8” tempered glass.
- Door:
- 3/8” tempered glass.
- 18” tallstainless steel door pull, inside and out.
- Width: 30” (left handed)
- Removable Carpet:
- Medium grey low pile commercial grade.
- Optional Interior furniture:
- Bench: Poly-leather (mink)
- Pod S: (1) 37”L x 20”D x 28”H
- Pod M: (2) 44”L x 20”D x 28”H
- Pod L: (2) 68”L x 20”D x 28”H
- Table: Solid phenolic (Grey, matte).
- Pod S: (1) 34”L x 18”D x 28.5”H w/ wall mount brackets
- Pod M: (2) 34”L x 30”D x 28.5”Hw/ wall mount bracket and silver metallic powder coated 1.25” mild steel table leg
- Pod L: (2) 57”L x 30”D x 28.5”Hw/ wall mount bracket and silver metallic powder coated 1.25” mild steel table leg
PART 3 EXECUTION
3.1 EXAMINATION
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
- Verify location is prepared to receive unit.
- Do not begin installation until unsatisfactory conditions have been corrected.
- INSTALLATION
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
- Install in accordance with manufacturer's instructions. Test for proper operation and adjust until satisfactory results are obtained.
- Install in accordance with standard industry practices and safeguards.
- CLEANING AND PROTECTION
- Clean exposed surface in accordance with manufacturer's instructions.
- Protect exposed surfaces from damage by subsequent construction.
END OF SECTION
12 59 00-1