Text for invitation to tender

Distribution manholes

Preliminary observations

Distribution manholes are water tight und preferable made of PE. Suitable shut-off devices in flow and return of each circuit or each probe shall be provided. For hydraulic compensation of the probe, qualified control equipment as well as filling and draining valves should be installed in the manholes.

During installation and backfilling of the manhole, static requirements has to be taken into consideration. Special requirements like traffic load or installation with soil water has to be considered during constructional dimensioning of the manhole and has to be enquired separately. Depending on load situation, further arrangements for transfer of loads or buoyancy protection have to be taken on site.

The manhole has to be backfilled and compressed in layers with non-binding filling material which fits the relevant standards. The filling material should be suitable for compaction, permeable, safe against sliding, frost-proof as well as free of spiky objects. The details of bedding according to the working sheets DVGW W 400-2 and ATV-A 127 as well as DIN EN 805 have to be taken into consideration. Superstructure and/or ascendancies through foundation load of buildings or similar should be ruled out. The corresponding distances of buildings or similar constructions has to be observed

Furthermore, the following standards have to be considered:

DIN 1054 Building ground – safety cases in earth and foundation work

DIN 4123 Excavations, creations and underpinnings in area of existing buildings

DIN 4124 Trenches and pits – slopes, pit lining, workspace

DIN 4084 Subsoil, area- and slope failure analysis

ATV-A 127 Guideline for static calculations of sewage canals and pipelines

ATV-A 139 Guideline for production of drainage canals and pipelines

Connection pipeline

The installation of the connection pipeline to the PKS-THERMPIPE® has to be done according to the known standards, especially according to DVGW working sheet W 400-2. All welding have to be done by qualified professional according to the known welding guidelines, e.g. DVS guideline 2207. The laying instructions of the producer have to be taken into consideration.

Stand: 22.11.2011 5 von 5

Pos. Produktbeschreibung EP EUR GP EUR

1 FRANK distribution manhole for THERMPIPE®, accessible

For connection of PKS-THERMPIPE®. Closed manhole made of PE with surface waterproof manhole cover; bottom plate and preparation for manhole cover welded,

Distributor d ...... x ...... mm, central and vertically installed;

-  2 pcs. connection to the heating pump made of solid walled pipe d 90 x 8,2 mm, SDR 11 with PVC ball valve, radially removable;

-  Flow connections made of solid walled pipe d 50 x 4,6 mm, SDR11, with PVC ball valve, radially removable;

-  Return connections made of solid walled pipe d 50 x 4,6 mm, SDR 11, with balancing valve Hydrocontrol, radially removable;

-  2 pcs. 1“ fill and draining valve;

-  Plastic cover with mechanical lock, entering 800 mm, accessible up to 200 kg;

-  All pipe connections are welded to the manhole wall watertight and each approx. 100 mm external overlap.

Design for:

Total volume flow: ………m3/h

Quantity of circuits: ………(max. 12 circuits)

Meets ……… m PKS-THERMPIPE® d ...... mm

Manhole height in mm: ………..

Diameter in mm: ……….

Item no.: 400 ......

Quantity: ...... St.

2 FRANK distribution manhole for THERMPIPE®, d 1000/1200, for BeGu cover, drivable

For connection of PKS-THERMPIPE®. Completely factory-assembled manhole made of PE 100 spiral pipe acc. to DIN 16961 for PKS-THERMPIPE®, produced with coextruded inspection friendly bright inner surface, lifting eyes and flat, under welded bottom made of PE.

Factory welded conical reducer 1070/1200 and telescopic height adjustable attachment piece, adjustable from 50 - 550mm, suitable for known BeGu covers.

Traffic load of the manhole for trucks, SLW ………..

A verifiable calculation should be provided.

Completely factory-assembled including flow/return made of PE100, SDR 11 - d ….. x ……mm;
Design horizontal, incl. All required valves.

Connection to the heating pump d ……x …. mm.

-  Flow and return incl. PVC ball valve type 21
(up to d 110mm)
Flow and return incl. PVC butterfly valve type 57
(ex d 125mm) and stub end with flange

Circuits for connection to PKS-THERMPIPE®:

-  Flow- PVC ball valve type 21 with long PE socket d50 x 4,6 mm, radially removable

-  Return – balancing valve Hydrocontrol, radially removable

-  All connections welded water tight to the outer wall of the manhole and each approx. 100mm external overlap.

Accessories per collection pipe:

-  Measuring adapter - 2 pcs. - PE-brass adapter 1/2" female, brass blind plug

-  Measuring valves - 1 pc. manometer 0 - 6 bar,
1 pc. thermometer -20/+60° incl. protection pipe

-  De-aeration - PE/brass changeover 3/4" female, brass blind plug, brass nickel aeration valve 3/4"

-  Filling and draining via PVC ball valve type 21,
with long PE sockets, DN 20

Total volume flow: ………m3/h

No. of circuits: ………

Corresponds ……… m PKS-THERMPIPE® d …… mm

Height in mm: ………..

Diameter in mm: 1000 / 1200

Quantity: ...... pieces

Complete delivery and installation of the manhole.

Performing of connection work.

Note: Cover is not part of the delivery of manhole.

FRANK distribution manhole for THERMPIPE®, d 1000/1200, incl. surface watertight manhole cover, drivable,

For connection of PKS-THERMPIPE®. Completely factory-assembled manhole made of PE 100 spiral pipe acc. to DIN 16961 for PKS-THERMPIPE®, produced with coextruded inspection friendly bright inner surface, lifting eyes and flat, under welded bottom made of PE.

Factory welded conical reducer 1070/1200 and telescopic height adjustable attachment piece, adjustable from 100 - 550mm. Manhole with surface watertight and lockable cover made of cast iron.

Traffic load of the manhole for trucks, SLW ………..

A verifiable calculation should be provided.

Completely factory-assembled including flow/return made of PE100, SDR 11 - d ….. x ……mm;
Design horizontal, incl. all required valves.

Connection to the heating pump d ……x …. mm.

-  Flow and return incl. PVC ball valve type 21
(up to d 110mm)
Flow and return incl. PVC butterfly valve type 57
(ex d 125mm) and stub end with flange

Circuits for connection to PKS-THERMPIPE®:

-  Flow- PVC ball valve type 21 with long PE socket d50 x 4,6 mm, radially removable

-  Return – balancing valve Hydrocontrol, radially removable

-  All connections welded water tight to the outer wall of the manhole and each approx. 100mm external overlap.

Accessories per collection pipe:

-  Measuring adapter - 2 pcs. - PE-brass adapter 1/2" female, brass blind plug

-  Measuring valves - 1 pc. manometer 0 - 6 bar,
1 pc. thermometer -20/+60° incl. protection pipe

-  De-aeration - PE/brass changeover 3/4" female, brass blind plug, brass nickel aeration valve 3/4"

-  Filling and draining via PVC ball valve type 21,
with long PE sockets, DN 20

Total volume flow: ………m3/h

No. of circuits: ………

Corresponds ……… m PKS-THERMPIPE® d …… mm

Height in mm: ………..

Diameter in mm: 1000 / 1200

Quantity: ...... pieces

Complete delivery and installation of the manhole.

Performing of connection work.

(for connection of more than 12 circuits )

4 FRANK distribution mahole for THERMPIPE®, drivable

For connection of PKS-THERMPIPE®. Completely factory-assembled manhole made of PE 100 spiral pipe acc. to DIN 16961 for PKS-THERMPIPE®, produced with coextruded inspection friendly bright inner surface, lifting eyes and flat, under welded bottom made of PE; with gasket on top of manhole, prepared for concrete cover plate bought locally.

Traffic load of the manhole for trucks, SLW ………..

A verifiable calculation should be provided.

Completely factory-assembled including flow/return made of PE100, SDR 11 - d ….. x ……mm;
Design horizontal, incl. all required valves.

Connection to the heating pump d ……x …. mm.

-  Flow and return incl. PVC ball valve type 21
(up to d 110mm)
Flow and return incl. PVC butterfly valve type 57
(ex d 125mm) and stub end with flange

Circuits for connection to PKS-THERMPIPE®:

-  Flow- PVC ball valve type 21 with long PE socket d50 x 4,6 mm, radially removable

-  Return – balancing valve Hydrocontrol, radially removable

-  All connections welded water tight to the outer wall of the manhole and each approx. 100mm external overlap.

Accessories per collection pipe:

-  Measuring adapter - 2 pcs. - PE-brass adapter 1/2" female, brass blind plug

-  Measuring valves - 1 pc. manometer 0 - 6 bar,
1 pc. thermometer -20/+60° incl. protection pipe

-  De-aeration - PE/brass changeover 3/4" female, brass blind plug, brass nickel aeration valve 3/4"

-  Filling and draining via PVC ball valve type 21,
with long PE sockets, DN 20

Total volume flow: ………m3/h

No. of circuits: ………

Corresponds ……… m PKS-THERMPIPE® d …… mm

Height in mm: ………..

Diameter in mm:…………

Quantity: ...... pieces

Complete delivery and installation of the manhole.

Performing of connection work.

All items delivered by : FRANK GmbH

Starkenburgstraße 1

64546 Mörfelden-Walldorf

Tel. +49 6105 4085-0

Fax +49 6105 4085-249

Internet: http://www.frank-gmbh.de