Safetran Leukocyte reduction filters / Transfusion sets
Catalogue Hospital Bedside
Hospital Bedside
Intended Use
Safetran leukocyte reduction filters have high quality leukoreduce performance. It can be easily operate by simply passing blood components through the filters. Safetran leukocyte reduction filters are effective products for removal of leukocytes and accumulated micro aggregates. Various units are available.
Performance Summary
500ml whole blood performed with set code: LW5022
Blood Age(hrs) / Volume(ml) / Pre-filtrationWBC X 109 / Post-filtration
WBC X 105
<1 / 500 / 7.78 / 0.33
<1 / 500 / 7.78 / 0.67
<1 / 500 / 7.78 / 1.3
<1 / 500 / 7.22 / 0
<1 / 500 / 7.22 / 0.67
<1 / 500 / 10 / 0.67
Product items
Description / kits Code // Transfusion chamber and blood filter 150um w/o pre-attached tube / 11
/ Transfusion chamber and blood filter 150um with attached straight administration set / 12
/ 2 spikes and one transfusion chamber with blood filter 150um w/o pre-attached tube / 21
/ 2 spikes and one transfusion chamber with blood filter 150um with attached straight administration set / 22
/ Transfusion chamber (vented) and blood filter 150um w/o pre-attached tube / 31
/ Transfusion chamber (vented)and blood filter 150um with attached straight administration set / 32
Ordering information
The above products are available for
FilterKits / For Whole Blood / For packed RBC / Platelet / Plasma
400ml / 500ml / ~150ml / ~250ml / 300ml / 400ml / 500ml / 6~12U / 3000ml
Bedside / 11 / LW4011 / LW5011 / / / LR2511 / LR3011 / / / / / / / LP3011
12 / LW4012 / LW5012 / / / LR2512 / LR3012 / / / / / / / LP3012
21 / LW4021 / LW5021 / LR1521 / LR2521 / LR3021 / LR4021 / LR5021 / LT1021 / LP3021
22 / LW4022 / LW5022 / LR1522 / LR2522 / LR3022 / LR4022 / LR5022 / LT1022 / LP3022
31 / LW4031 / LW5031 / / / LR2531 / LR5031 / / / / / / / LP3031
32 / LW4032 / LW5032 / / / LR2532 / LR5032 / / / / / / / LP3032
41 / / / / / / / / / / / / / / / LT1041 / LP3041
42 / / / / / / / / / / / / / / / LT1042 / LP3042
Other product codes are available please contact us for more details.
Safetran Leukocyte reduction filters / Transfusion sets
Catalogue Hospital Bedside
Leukocyte reduction filters for whole blood transfusion
Features & Specifications
l Designed for whole blood for bedside use
l High efficiency filtration
l High leukocyte reduction <105
l High RBC recovery > 90%
l Minimal loss of red cells
l Friendly handling, No saline prim or flush required
l Single use
Ordering information
Process volume / Reorder code / Description400 / LW4011 / chamber and blood filter 150um w/o pre-attached tube
LW4012 / chamber and blood filter 150um with attached straight administration set
LW4021 / 2 spikes and one chamber with blood filter 150um w/o pre-attached tube
LW4022 / 2 spikes and one chamber with blood filter 150um with attached straight administration set
LW4031 / Chamber (vented) and blood filter 150um w/o pre-attached tube
LW4032 / Chamber (vented)and blood filter 150um with attached straight administration set
500 / LW5011 / chamber and blood filter 150um w/o pre-attached tube
LW5012 / chamber and blood filter 150um with attached straight administration set
LW5021 / 2 spikes and one chamber with blood filter 150um w/o pre-attached tube
LW5022 / 2 spikes and one chamber with blood filter 150um with attached straight administration set
LW5031 / Chamber (vented) and blood filter 150um w/o pre-attached tube
LW5032 / Chamber (vented)and blood filter 150um with attached straight administration set
Leukocyte reduction filters for Red blood cell transfusion
Features & Specifications
l Designed for Red cell transfusion for bedside use
l High efficiency filtration
l High leukocyte reduction <105
l High RBC recovery > 90%
l Minimal loss of red cells
l Friendly handling, No saline prim or flush required
l Single use
Ordering information
Process volume / Reorder code / Description~250ml / LR2511 / chamber and blood filter 150um w/o pre-attached tube
LR2512 / chamber and blood filter 150um with attached straight administration set
LR2521 / 2 spikes and one chamber with blood filter 150um w/o pre-attached tube
LR2522 / 2 spikes and one chamber with blood filter 150um with attached straight administration set
LR2531 / Chamber (vented) and blood filter 150um w/o pre-attached tube
LR2532 / Chamber (vented)and blood filter 150um with attached straight administration set
~300ml / LR3011 / chamber and blood filter 150um w/o pre-attached tube
LR3012 / chamber and blood filter 150um with attached straight administration set
LR3021 / 2 spikes and one chamber with blood filter 150um w/o pre-attached tube
LR3022 / 2 spikes and one chamber with blood filter 150um with attached straight administration set
LR5031 / Chamber (vented) and blood filter 150um w/o pre-attached tube
LR5032 / Chamber (vented)and blood filter 150um with attached straight administration set
400ml / LR4021 / 2 spikes and one chamber with blood filter 150um w/o pre-attached tube
LR4022 / 2 spikes and one chamber with blood filter 150um with attached straight administration set
500ml / LR5021 / 2 spikes and one chamber with blood filter 150um w/o pre-attached tube
LR5022 / 2 spikes and one chamber with blood filter 150um with attached straight administration set
Leukocyte reduction filters for Platelet transfusion
Features & Specifications
l High leukocyte reduction <105
l Minimal loss of red cells
l Friendly handling, No saline prim or flush required
l Single use
Ordering information
Process volume / Reorder code / Description6~12U / LT1041 / 6 spikes and one chamber with blood filter 150um w/o pre-attached tube
LT1042 / 6 spikes and one chamber with blood filter 150um with attached straight administration set
Leukocyte reduction filters for Plasma transfusion
Process volume / Reorder code / Description3000ml / LT1041 / 6 spikes and one chamber with blood filter 150um w/o pre-attached tube
LT1042 / 6 spikes and one chamber with blood filter 150um with attached straight administration set
Safetran Biomedical INC
No. 1, Lane 16, Alley 120, LiDe Road , Taipei , Taiwan , R.O.C.
Email: Tel: +886- 2- 2876-5958 Fax: +886- 2- 2876-5955