ATTACHMENT C
CRITERIA FOR CERTIFICATION OF FUNCTION POINT SOFTWARE TYPE 2
Applicant ______
(Company Name)
This document provides the critical items that should be covered using software for function point counting.
Type 2 software provides Function Point data collection and calculation functionality, where the user and the system/software determine the Function Point count interactively; the user answers to the questions made to him by the system/software and the system/software makes decisions about the count, records it and performs the appropriate calculations.
The software and its associated documentation must conform to the Counting Practices Manual. Each mandatory (not optional) item must be covered in detail in the software and also in the documentation. Each optional item should be covered in detail in the software and in the documentation.
The items required to be automatically identified by the system/software are represented in the appropriates check-lists by (AI) (AI = Automate Identification).
The items that may be entered in the system manually by the user are represented in the appropriates check-lists by (MI) (MI = Manual Input).
The items that may be either automatically identified by the system/software or entered/refined manually by the user are represented by (AI/MI).
In the table below, please note the page number(s) in the space provided to identify the location of that criterion in your printed software documentation. Also, please note the menu number(s) or alpha(s) in the space provided to identify the location of that criterion in your software. Make sure all items in the checklist are covered. Failure to do so will result in your material being classified as “incomplete”.
DocumentationPage Number / Software
Menu Number / Criteria / Reviewer’s Comments
A. DESCRIPTIVE INFORMATION
- ID of application/project (MI)
- Name of application/project (MI)
- Description of application/project (MI)
- Type of count (MI)
- Link between the Enhancement Projects and the modified application(s) (MI)
B. FUNCTION TYPES
- Each user identifiable group of logically related data or control information referenced by the application/project being counted, but maintained within the boundary of another application and having as primary intent to hold data referenced through one or more elementary processes within the boundary of the application/project being counted is identified as an ExternalInterfaceFile (EIF) (AI)
b)Description (MI)
c)If it represents Conversion Functionality (optional, MI)
d)Each unique user recognizable, non-repeated field retrieved from the EIF through the execution of an elementary process is counted as a DET (AI/MI)
e)Name of DETs (optional, MI)
f)Each user recognizable subgroup of data elements within the EIF is counted as a RET (AI/MI)
- Each user identifiable group of logically related data or control information maintained within the boundary of the application/project being counted and having as primary intent to hold data maintained through one or more elementary processes of the application/project being counted is identified as an InternalLogicalFile (ILF) (AI)
Documentation
Page Number / Software
Menu Number / Criteria / Reviewer’s Comments
a)Description (MI)
b)If it represents Conversion Functionality (optional, MI)
c)Each unique user recognizable, non-repeated field maintained in the ILF through the execution of an elementary process is counted as a DET (AI/MI)
d)Name of DETs (optional, MI)
e)Each user recognizable subgroup of data elements within the ILF is counted as a RET (AI/MI)
- Elementary process that processes data or control information that comes from outside the application/project’s boundary being counted and having as primary intent to maintain one or more ILFs and/or to alter the behavior of the system, is identified as an External Input (EI) (AI)
b)Description (MI)
c)If it represents Conversion Functionality (optional, MI)
d)Each user recognizable, non-repeated field that enters or exits the application/project’s boundary being counted and is required to complete the EI is counted as a DET (AI/MI)
e)The capability of the application/project being counted to send a system response message outside it’s boundary to indicate an error occurred during processing, confirm that processing is complete or verify that processing should continue is counted as one DET (AI)
f)The ability of the application/project being counted to specify an action to be taken is counted as one DET, even if there are multiple methods for invoking the same logical process (AI)
g)Name of DETs (optional, MI)
Documentation
Page Number / Software
Menu Number / Criteria / Reviewer’s Comments
h)Capability to select the logical file maintained/read by the EI from the ILFs and/or EIFs (MI)
i)Each different ILF/EIF maintained/read by the EI is counted as an FTR (AI)
- Elementary process that sends data or control information outside the application/project’s boundary being counted and having as primary intent to present information to a user through processing logic (that contains at least one mathematical formula or calculation, or create derived data) other than, or in addition to, the retrieval of data or control information is identified as an ExternalOutput (EO) (AI)
b)Description (MI)
c)If it represents Conversion Functionality (optional, MI)
d)Each user recognizable, non-repeated field that enters the application/project’s boundary being counted and is required to specify when, what and/or how the data is to be retrieved or generated is counted as a DET (AI/MI)
e)Each user recognizable, non-repeated field that exits the application/project’s boundary being counted is counted as a DET (AI/MI)
f)If a DET both enters and exits the boundary, it is counted only once for the EO (AI)
g)The capability of the application/project being counted to send a system response message outside it’s boundary to indicate an error occurred during processing, confirm that processing is complete or verify that processing should continue is counted as one DET (AI)
Documentation
Page Number / Software
Menu Number / Criteria / Reviewer’s Comments
h)The ability of the application/project being counted to specify an action to be taken is counted as one DET, even if there are multiple methods for invoking the same logical process (AI)
i)Name of DETs (optional, MI)
j)Capability to select the logical file maintained/read by the EO from the ILFs and/or EIFs (MI)
k)Each different ILF/EIF maintained/read by the EO is counted as an FTR (AI)
- Elementary process that sends data or control information outside the application/project’s boundary being counted and having as primary intent to present information to a user through processing logic (that contains no mathematical formula or calculation, and creates no derived data) of retrieval of data or control information from an ILF or EIF is identified as an External Inquiry (EQ) (AI)
a)ID, or number, or name (AI/MI)
b)Description (MI)
c)If it represents Conversion Functionality (optional, MI)
d)Each user recognizable, non-repeated field that enters the application/project’s boundary being counted and is required to specify when, what and/or how the data is to be retrieved is counted as a DET (AI/MI)
e)Each user recognizable, non-repeated field that exits the application/project’s boundary being counted is counted as a DET (AI/MI)
f)If a DET both enters and exits the boundary, it is counted only once for the EQ (AI)
Documentation
Page Number / Software
Menu Number / Criteria / Reviewer’s Comments
g)The capability of the application/project being counted to send a system response message outside it’s boundary to indicate an error occurred during processing, confirm that processing is complete or verify that processing should continue is counted as one DET (AI)
h)The ability of the application/project being counted to specify an action to be taken is counted as one DET, even if there are multiple methods for invoking the same logical process (AI)
i)Name of DETs (optional, MI)
l)Capability to select the logical file read by the EQ from the ILFs and/or EIFs (MI)
m)Each different ILF/EIF read by the EQ is counted as an FTR (AI)
C. GENERAL SYSTEM CHARACTERISTICS
- Listing of GSCs (AI/MI)
- Degree of Influence (0-5 only) (AI/MI)
D. UPDATE CAPABILITY FOR DEVELOPMENT PROJECT (full optional)
- Created application
a)Function types of the Development Project are included as Function types of the created application (AI)
b)Function types defined as Conversion Functionality of the Development project are not included as Function types of the created application (AI)
- General System Characteristics
a)Degrees of influence of the GSCs of the created application are initialized (AI)
Documentation
Page Number / Software
Menu Number / Criteria / Reviewer’s Comments
E. UPDATE CAPABILITY FOR ENHANCEMENT PROJECT (full optional)
- Modified application
a)Function types of the modified application include the Function types ADDED by the Enhancement project (AI)
b)Function types of the modified application are replaced with the Function types CHANGED by the Enhancement project (AI)
c)Function types of the modified application no longer include the Function types DELETED by the Enhancement project (AI)
d)Function types defined as Conversion Functionality of the Enhancement project are not included as Function types of the modified application (AI)
- General System Characteristics
F. AUTOMATED CALCULATIONS
- Complexity for Function Types (L, A, H)
a)EIF
b)ILF
c)EI
d)EO
e)EQ
- Total for GSCs
- Project Adjusted Function Point Count
- Application Initial Function Point Count (optional)
- Application Function Point Count after the enhancement project (optional)
G. DISPLAY/REPORTS (no special format)
- Ability to display/print items input
- Ability to display/print calculations
H. IFPUG REFERENCE
- Counting Practices Manual
- Release/Version
Page 1
Revised October, 1999