R.JAIGANESH

Mobile no: +966-559689072

______

13 Years of Rich Experiences inElectrical Maintenance in Various fields. And including 1.5 Years Experience in KSA as a District Engineer in STC contract of Seder Engineering.

  • Proficiency in managing Preventive maintenance, Breakdown maintenance of various equipment for reducing downtime and enhancing operational effectiveness.
  • Handling Electro Mechanical Equipment (HVAC, Rectifier, Diesel Generator, ATS Etc.,)
  • Excellent interpersonal skills with strong analytical, team building, problem solving and organizational abilities.
  • Familiarity with safe electrical work practices, hazard assessments and personal protective equipment.

TECHNICAL EXPERIENCE 3

Working as a District Engineer (Operation and Maintenance) in SEDER ENGINEERING, JIZAN, KSA. For SAUDI TELECOM COMPANY, KSA from Nov 2014 to till date

Role

Fallow up the PMR, CMR and Breakdown maintenance of the Electrical Equipment like HVAC, DG, Rectifier and Lighting.

Responsibility of trouble shooting maintenance and operation of the Rectifier, HVAC, Air-conditioning and Control Panels etc.,

Maintaining strict control of all repairing and maintenance cost, spare parts, timing and tools.

Make Daily Work schedule for the Engineers and Technician.

Prepare the Daily and Monthly reports

Arrange the Spares for All Equipment, Minimize the Spares and Consumable.

Summiting a technical report on the status of the equipment and spare parts.

ACADEMIC QUALIFICATION

  • B.E (Electrical and Electronics) from M.A.M. College of Engineering. Tiruchy, in 2002.
  • D.E.E.E from M.I.E.T Polytechnic, Tiruchy in 1997

TECHNICAL EXPERIENCE 2

Worked as a Sr. Electrical engineer, Chennai Radha Engineering works PVT LTD. In JSW JAIGARH Port LTD, Operation and Maintenance of Material Handling System, Jaigarh, Ratnagiri, Maharastra, from April 2013 to March 2014.

Role and Duties

  • Maintenance and attended the Trouble shooting for Ship unloader (ZPMC Rated Capacity 52T/Hr
  • Fallow up the all kind of Preventive Maintenance, Breakdown and Corrective and repair Maintenance.
  • Ensure that Equipment is in good working so as to prevent disruption and activities.
  • Provide 24Hr day maintenance service or assign technical staff to do so.
  • Handling the 6.6KV Vacuum Circuit Breaker and LT ACB.
  • Handling and Maintain the Stacker cum Reclaimber Capacity of 2400T/Hr.

TECHNICAL EXPERIENCE

Worked as an Electrical Engineer, Chennai Radha Engineering Works PVT LTD. In BALCO CPP (4*135)MW Maintenance of Coal Handling and Ash Handling Plant, Korba, Chhattisgarh from Nov 2005 to April 2013

Role

  • Identifying scope for planning, implementing & monitoring for technological changes to enhance productivity.
  • Expertise in installing, testing, commissioning & Maintenance of electrical equipments.
  • Ensure that safe work practices were followed in the facility.
  • Ensure that all the electrical systems were safe and reliable.
  • Knowledge and troubleshooting experience of HT/LT Motors, MCC Panels, HT/LT Switchgears, AC Drives, Stacker Cum Recamier Machines, and Different types of Electrical Instrument.
  • Scheduled the electrical work in co-ordination with the electrical technician and clients.
  • Handle the work of the project and participation in daily weekly meeting with my department
  • Engineers, Technicians and Clients
  • Implementing PTW/LOTO System at Plant.
  • Trouble shooting analysis of motor control and various types of drives, like ABB (ACS 550 and ACS 880), SIEMENS Micromaster 440, Telemachanique (Altiver 31, Altiver 28), Fuji (Frenic 5000 G11).

KEY RESPONSIBILITY

Handling Induction Motor HT & LT, Air Circuit Breaker (300A to 1033A), Vacuum Circuit Breaker (6.6KV)

Dry Type Transformer (1500kva)

Oil Type Transformer (1000kva)

PCC and MCC

All Routine Preventive Maintenance, Corrective and Repair Maintenance, Break down maintenance.

Spare required for all specified equipment.

 Lighting.

Trouble shooting analysis of Motor Controls, Drives and PLC.

Checklist preparation for all Electrical equipment like Transformer, LT, HT Motor and Local control Panel.

Investigate the problem and recommend solution

HT & LT Motorsoverhauling

HT Cable joined

PREVIOUS EXPERIENCE

Worked as an Electrical Engineer in Veena Fabric PVT LTD, Thirupur from Mar 2003 to Mar 2004

RESPONSIBILITY

Electrical Power Generator (125KVA, 120KVA, 135KVA)

Compressor (40HP, 50HP)

Motor control starters and switches.

Air Dryer.

Knitting machine Maintenance.

PROFESSIONAL TRAINING

Certified Automation Engineer from Prolific System of Solution PVT, LTD Chennai.

Hardware:

  • Modicon Telemechnique – TSX Micro, TSX Premium
  • Allen-Bradley- SLC 500, Micrologix 1000, Micrologix 5555

Programming Software:

  • PL 7 Pro V3.3, V4.3 from Telemecanique
  • RS-Logix 500v, RS-Logix 5000 from Rockwell Software.

PERSONAL DETAILS

Father’s Name : P.Ramachandran

Date of Birth : 29.12.1978

Marital Status : Married

Address : No: 21, ACS Nagar, Nachikurichi, Vayalur Road, Tiruchy, Tamilnadu

INDIA.

Passport No : L3682725

I hereby declare that the above written particulars are true.