Copyright 2017 AIA MasterSpec Premium 03/17

PRODUCT MASTERSPEC LICENSED BY ARCOM TO RODDA PAINT CO.

Copyright 2017 by The American Institute of Architects (AIA)

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

This Product MasterSpec Section is licensed by ARCOM to Rodda Paint Co. ("Licensee").

This Product MasterSpec Section modifies the original MasterSpec text.

Revisions made to the original MasterSpec text are made solely by the Licensee and are not endorsed by, or representative of the opinions of, ARCOM or The American Institute of Architects (AIA). Neither AIA nor ARCOM are liable in any way for such revisions or for the use of this Product MasterSpec Section by any end user. A qualified design professional should review and edit the document to suit project requirements.

For more information, contact Rodda Paint Co., 6017 N. Marine Dr., Portland, OR 97203; Phone: (800)452-2315 | (503) 737-6033; Fax: (503) 737-6004; Website: www.roddapaint.com.

For information about MasterSpec contact ARCOM at (800) 424-5080 or visit www.MasterSpec.com.

SECTION 099123 - INTERIOR PAINTING

TIPS:

To view non-printing Editor's Notes that provide guidance for editing, click on MasterWorks/SingleFile Formatting/Toggle/Editor's Notes.

To read detailed research, technical information about products and materials, and coordination checklists, click on MasterWorks/Supporting Information.

This Section is intended to be edited using ARCOM's SpecBuilder and the MPI Architectural Painting Decision Tree, located at www.ARCOMone.com/MPI. Double click here to connect.

Revise this Section by deleting and inserting text to meet Project-specific requirements.

This Section uses the term "Architect." Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions.

Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed.

PART 1 - GENERAL

1.1  RELATED DOCUMENTS

Retain or delete this article in all Sections of Project Manual.

A.  Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division01 Specification Sections, apply to this Section.

1.2  SUMMARY

A.  Section includes surface preparation and the application of paint systems on [interior substrates.] [the following interior substrates:]

1.  Concrete.

2.  Cement board.

3.  Clay masonry.

4.  Concrete masonry units (CMUs).

5.  Steel and iron.

6.  Galvanized metal.

7.  Aluminum (not anodized or otherwise coated).

8.  Copper.

9.  Stainless steel.

10.  Wood.

11.  Fiberglass.

12.  Plastic.

13.  Gypsum board.

14.  Plaster.

15.  Acoustic panels and tiles.

16.  Spray-textured ceilings.

17.  Cotton or canvas insulation covering.

18.  ASJ insulation covering.

19.  Bituminous-coated surfaces.

B.  Related Requirements:

Retain subparagraphs below to cross-reference requirements Contractor might expect to find in this Section but are specified in other Sections.

Primers in other Sections must be coordinated for compatibility with finish coats specified in this Section. Review other Sections for shop-primed products, and insert references to this Section to establish primer requirements.

1.  [Section051200 "Structural Steel Framing"] [Section051213 "Architecturally Exposed Structural Steel Framing"] for shop priming structural steel.

2.  Section055000 "Metal Fabrications" for shop priming metal fabrications.

3.  Section055113 "Metal Pan Stairs" for shop priming metal pan stairs.

4.  Section055116 "Metal Floor Plate Stairs" for shop priming metal floor plate stairs.

5.  Section055119 "Metal Grating Stairs" for shop priming metal grating stairs.

6.  Section055213 "Pipe and Tube Railings" for shop [priming] [painting] pipe and tube railings.

7.  [Section055313 "Bar Gratings"] [Section055316 "Plank Gratings"] [Section055319 "Expanded Metal Gratings"] for shop priming metal gratings.

8.  Section099300 "Staining and Transparent Finishing" for surface preparation and the application of wood stains and transparent finishes on interior wood substrates.

9.  Section099600 "High-Performance Coatings" for tile-like coatings.

1.3  DEFINITIONS

Retain this article if paints are specified by manufacturers' trade names rather than by MPI paint numbers. Definitions of MPIGloss Levels below are from "MPI Architectural Painting Specification Manual" (hereafter, "MPI Manual").

Retain terms that remain after this Section has been edited for a project.

A.  MPIGloss Level1: Not more than five units at 60 degrees and 10 units at 85 degrees, according to ASTMD523.

B.  MPIGloss Level2: Not more than 10 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTMD523.

C.  MPIGloss Level3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTMD523.

D.  MPIGloss Level4: 20 to 35 units at 60 degrees and not less than 35 units at 85 degrees, according to ASTMD523.

E.  MPIGloss Level5: 35 to 70 units at 60 degrees, according to ASTMD523.

F.  MPIGloss Level6: 70 to 85 units at 60 degrees, according to ASTMD523.

G.  MPIGloss Level7: More than 85 units at 60 degrees, according to ASTMD523.

1.4  ACTION SUBMITTALS

A.  Product Data: For each type of product. Include preparation requirements and application instructions.

See "Writing Guide" Article in the Evaluations for discussion of first subparagraph below.

1.  Include Printout of current "MPI Approved Products List" for each product category specified, with the proposed product highlighted.

2.  Indicate VOC content.

B.  Sustainable Design Submittals:

"Product Data" Subparagraph below applies to LEED 2009 NC, CI, and CS; LEEDv4; IgCC; ASHRAE189.1; and Green Globes. Coordinate with requirements for paints and coatings.

  1. Product Data: For paints and coatings, indicating VOC content.

"Laboratory Test Reports" Subparagraph below applies to LEED 2009 for Schools, LEEDv4, IgCC, ASHRAE189.1, and Green Globes. Coordinate with requirements for paints and coatings.

  1. Laboratory Test Reports: For paints and coatings, indicating compliance with requirements for low-emitting materials.

C.  Samples for Initial Selection: For each type of topcoat product.

Delete "Samples for Initial Selection" Paragraph above if colors and other characteristics are preselected and specified or scheduled. Retain "Samples for Verification" Paragraph below with or without above.

D.  Samples for Verification: For each type of paint system and in each color and gloss of topcoat.

Color and gloss of Samples change as they age; seven-day old Samples appear different from freshly dried Samples.

1.  Submit Samples on rigid backing, 8 inches (200 mm) square.

2.  Apply coats on Samples in steps to show each coat required for system.

3.  Label each coat of each Sample.

4.  Label each Sample for location and application area.

E.  Product List: Cross-reference to paint system and locations of application areas. Use same designations indicated on Drawings and in schedules. Include color designations.

1.5  MAINTENANCE MATERIAL SUBMITTALS

A.  Furnish extra materials[,from the same product run,] that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

If necessary, replace percentage in "Paint" Subparagraph below with a specific number of gallons (liters) or cases and include an expanded description of the quantity of each material and color.

1.  Paint: [5] <Insert number> percent, but not less than [1 gal. (3.8L)] <Insert number> of each material and color applied.

1.6  QUALITY ASSURANCE

A.  Mockups: Apply mockups of each paint system indicated and each color and finish selected to verify preliminary selections made under Sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution.

1.  Architect will select one surface to represent surfaces and conditions for application of each paint system.

a.  Vertical and Horizontal Surfaces: Provide samples of at least 100 sq. ft. (9 sq.m).

b.  Other Items: Architect will designate items or areas required.

2.  Final approval of color selections will be based on mockups.

a.  If preliminary color selections are not approved, apply additional mockups of additional colors selected by Architect at no added cost to Owner.

3.  Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless Architect specifically approves such deviations in writing.

Retain subparagraph below if the intention is to make an exception to the default requirement in Section014000 "Quality Requirements" for demolishing and removing mockups.

4.  Subject to compliance with requirements, approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion.

1.7  DELIVERY, STORAGE, AND HANDLING

A.  Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 degF (7 degC).

1.  Maintain containers in clean condition, free of foreign materials and residue.

2.  Remove rags and waste from storage areas daily.

If necessary, insert special requirements for fire protection, heating, ventilation, and other conditions for storage areas on-site.

1.8  FIELD CONDITIONS

A.  Apply paints only when temperature of surfaces to be painted and ambient air temperatures are between 50 and 95 degF (10 and 35 degC).

B.  Do not apply paints when relative humidity exceeds 85 percent; at temperatures less than 5 degF (3 degC) above the dew point; or to damp or wet surfaces.

PART 2 - PRODUCTS

Manufacturers and products listed in SpecAgent and MasterWorks Paragraph Builder are neither recommended nor endorsed by the AIA or ARCOM. Before inserting names, verify that manufacturers and products listed there comply with requirements retained or revised in descriptions and are both available and suitable for the intended applications. For definitions of terms and requirements for Contractor's product selection, see Section 016000 "Product Requirements."

2.1  MANUFACTURERS

Retain "Basis-of-Design Product" Paragraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed.

  1. Basis-of-Design Product: Subject to compliance with requirements, provide Interior Painting Schedule at end of Part3 or comparable products by one of the following:
  2. Behr Process Corporation.
  3. Benjamin Moore & Co.
  4. California Paints.
  5. Conco Paints.
  6. Coronado Paint; a Benjamin Moore Company.
  7. Diamond Vogel Paints.
  8. Dulux (formerly ICI Paints); a brand of AkzoNobel.
  9. Dunn-Edwards Corporation.
  10. Duron, Inc.
  11. Frazee Paint; Comex Group.
  12. Glidden Professional.
  13. Kelly-Moore Paint Company Inc.
  14. Kwal Paint; Comex Group.
  15. M.A.B. Paints.
  16. McCormick Paints.
  17. Parker Paint; Comex Group.
  18. PPG Architectural Coatings.
  19. Pratt & Lambert.
  20. Rodda Paint Co.
  21. Rust-Oleum Corporation; a subsidiary of RPM International, Inc.
  22. Sherwin-Williams Company (The).
  23. United Gilsonite Laboratories.
  24. Valspar Corporation - Architectural (Pro).
  25. Vista Paint Corporation.
  26. Zinsser; Rust-Oleum Corporation.
  27. Insert manufacturer's name>.

Retain "Products" Paragraph below and insert lists of manufacturers and products in Interior Painting Schedule to require specific products or a comparable product from other manufacturers.

See lists of products currently approved by MPI in its "MPI Approved Products Lists." See "Writing Guide" Article in the Evaluations for further discussion.

B.  Products: Subject to compliance with requirements, [provide product] [provide one of the products] [available products that may be incorporated into the Work include, but are not limited to products] listed in the Interior Painting Schedule for the paint category indicated.

2.2  PAINT, GENERAL

A.  MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its "MPI Approved Products Lists."

B.  Material Compatibility:

Systems could fail if paints used for individual coats are incompatible. MPI's paint systems match primers and topcoats and take compatibility into consideration.

1.  Materials for use within each paint system shall be compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

2.  For each coat in a paint system, products shall be recommended in writing by topcoat manufacturers for use in paint system and on substrate indicated.

"VOC Content" Paragraph below applies to LEED 2009 NC, CI, and CSCreditIEQ4.2.

  1. VOC Content: For field applications that are inside the weatherproofing system, paints and coatings shall comply with VOC content limits of authorities having jurisdiction and the following VOC content limits:

Categories in subparagraphs below are taken from LEED rating systems and the standards referenced by them; if clarification is required, see those documents or the reference guides.

  1. Flat Paints and Coatings: 50g/L.
  2. Nonflat Paints and Coatings: 50g/L.
  3. Dry-Fog Coatings: 150g/L.
  4. Primers, Sealers, and Undercoaters: 100g/L.
  5. Rust-Preventive Coatings: 100g/L.
  6. Zinc-Rich Industrial Maintenance Primers: 100g/L.
  7. Pretreatment Wash Primers: 420g/L.
  8. Shellacs, Clear: 730g/L.
  9. Shellacs, Pigmented: 550g/L.

"Low-Emitting Materials" Paragraph below applies to LEED 2009 for Schools.

  1. Low-Emitting Materials: Interior paints and coatings shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers."

"VOC Content" and "Low-Emitting Materials" paragraphs below apply to LEEDv4.

  1. VOC Content: For field applicationsthat are inside the weatherproofing system, paints and coatings shall comply with VOC content limits of authorities having jurisdiction and the following VOC content limits:

Categories in subparagraphs below are taken from LEED rating systems and the standards referenced by them; if clarification is required, see those documents or the reference guides.

  1. Flat Paints and Coatings: 50g/L.
  2. Nonflat Paints and Coatings: 50g/L.
  3. Dry-Fog Coatings: 150g/L.
  4. Primers, Sealers, and Undercoaters: 100g/L.
  5. Rust-Preventive Coatings: 100g/L.
  6. Zinc-Rich Industrial Maintenance Primers: 100g/L.
  7. Pretreatment Wash Primers: 420g/L.
  8. Shellacs, Clear: 730g/L.
  9. Shellacs, Pigmented: 550g/L.
  10. Low-Emitting Materials: For field applications that are inside the weatherproofing system, 90 percent of paints and coatings shall comply with the requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers."

"Material Emissions and Pollutant Control" Paragraph below applies to IgCC.

  1. Material Emissions and Pollutant Control: Not less than 85 percent of field-applied paints and coatings that are inside the weatherproofing system shall comply with either of the following:
  2. Low-Emitting Materials: VOC emissions shall comply with the requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." Formaldehyde emissions shall not exceed 9 mcg/cu.m or 7 ppb, whichever is less.
  3. VOC content shall not exceed limits of authorities having jurisdiction and the following:
  4. Flat Coatings: 50g/L.
  5. Nonflat Coatings: 100g/L.
  6. Nonflat - High-Gloss Coatings: 150g/L.
  7. Dry-Fog Coatings: 150g/L.
  8. Industrial Maintenance Coatings: 250g/L.
  9. Pretreatment Wash Primers: 420g/L.
  10. Primers, Sealers, and Undercoaters: 100g/L.
  11. Recycled Coatings: 250g/L.
  12. Rust-Preventive Coatings: 250g/L.

"Emissions Requirements" Paragraph below applies to ASHRAE189.1.