Project Information
Company NameContact Person; Name / Position
Telephone / Fax Number
Name ofthe End User / Site
Description / Value
- Common data
1.1 / ProjectName
1.2 / Projectlocation
- Quotation terms
2.1 / Expectedclosedate
2.2 / Warranty period duration, months
2.3 / Expectedequipmentdelivery
2.4 / Terms ofdelivery
- Surroundingconditions
3.1 / Min.and Maxambienttemperature, °C
3.2 / Site altitude, m
3.3 / Seismic requirements
3.4 / Wind load, kPa
3.5 / Snow load, kPa
3.6 / Hazardous area
- Compressorunitsdata
4.1 / Quantityofcompressorunits
4.2 / Annual operation, hours
- Gasdata
5.1 / ProcessGas Compositionmol. %:
СН4 / i-C5Н12 / N2 / H2
С2Н6 / n-C5Н12 / CO2 / O2
С3Н8 / n-C6Н14 / He / СО
i-C4Н10 / n-C7Н16 / H2S
n-C4Н10 / n-C8Н18 / H2O
5.2 / Inlet gas humidity, %
5.3 / Max. sizeand qty of mechanical particles at inlet
5.4 / Max. sizeand qty of liquid particles at inlet
5.5 / Maximum contentofoil,
ppmW at outlet
- Processparameters
6.1 / Gas inletpressure min/max MPa,gauge
6.2 / Gas inlettemperaturemin/max, °C
6.3 / Gas dischargepressure, MPa (gauge)
6.4 / Gas outlettemperature,°C
6.5 / Gas Flow max (ofonecompressorunit), Nm3/h
(0 ºС; 101,325 kPa absolute)
- Equipment configuration
7.1 / Compressor unit execution / Indoor (without acoustic enclosure)___
Indoor (with acoustic enclosure)___
Outdoor___
7.2 / Switchboardslocation / Remoteinstallation___
Separatecompartmentofacousticenclosure___
7.3 / Compressorsdrivenby / Electric motor____
Gas Engine____
7.4.1 / Mainmotor power supply, kV
7.4.2 / Softstarter for main motorenquiry / tobeincluded_____
don`t needed_____
7.4.3
7.5 / Valves drives type / air ___
electircal ___
7.6
7.7.1 / Coolertype / air___
water___
7.7.2 / Inletwatertemp., °C
7.7.3 / Outletwatertemp., °C
7.7.4 / Water inlet pressure, MPa gauge
7.7.5 / Flow rate, m3/h
7.7.6 / Water pH
7.7.7 / Water composition
transparence - sm
suspended solids – mg/l
ammonium nitrogen – mg/l
nitrite – mg/l
oxidability – mg/O2
alkalinity – mg-eqv/l
chlorides – mg/l
sulphate – mg/l
Fe – mg/l
dry particles – mg/l
coloration – degree
dissolved O2– mg/l
turbidity – mg/l
rigidity – mg-eqv/l
- Options
8.1 / Witnessed or un-witnessed test for QCP / tobeincluded___
8.2 / Special tools / tobeincluded___
8.3 / Spare parts:
- for a commissioning
- for a guarantee period / tobeincluded___
tobeincluded___
8.4 / Oilsupply
- first filling / tobeincluded___
8.5 / Glycol supply
- first filling / tobeincluded___
8.6 / Comments
Please, send us the filled-out questionnaire by:
E-mail: [email protected]