SECTION 28 13 00
ACCESS CONTROLS
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2007 - 2017 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** LiftMaster; Access Control Systems, Telephone Entry Control Systems, Parking Control Systems.
.
This section is based on the products of LiftMaster, which is located at:
300 Windsor Dr.
Oak Brook, IL 60523
Toll Free Tel: 800-282-6225
Fax: 630-516-8412
Email: request info ()
Web: LiftMaster.com
[ Click Here ] for additional information.
LiftMaster's full commercial and residential garage door operator/gate operator/access control product lines meet the needs of Architects, Designers, Engineers, and Specifiers in any design or conceptual plan, while offering 100 percent compliance with UL 325-2010 safety and construction codes. Our entire product line also contributes to energy-efficiency credits for LEED green building certification from the U.S. Green Building Council. LiftMaster is a registered presenter of the American Institute of Architects and is approved to present any of our AIA CEUs at your firm's location. For learning objectives and to schedule a Lunch & Learn for your firm, please send a request to .
Find a complete library of architectural specifications, shop drawings, CSI format 3-part specs, CAD, and BIM product renderings, visit LiftMaster.com.
PART 1 GENERAL
1.1 SECTION INCLUDES
** NOTE TO SPECIFIER ** Delete, add items below not required for project.
A. Access Control Systems:
1. Single entry access keypad and proximity reader (LiftMaster Model KPR2000).
2. Wireless access control keypad (LiftMaster Models KPW5, KPW250).
3. Stand-alone keypad access control system (LiftMaster Model MINIkey).
4. Commercial universal receiver with antenna (LiftMaster Model STAR1000).
5. Wireless single push-button control station (LiftMaster Model WPB1LM3).
6. Wireless 3-button control station (LiftMaster Model WPB3LM3).
7. Passport stand-alone proximity card reader (LiftMaster Model PPLX).
8. Passport receiver and remote access control (LiftMaster Model PPWR).
B. Telephone Entry Control Systems:
1. Single tenant telephone entry systems (LiftMaster Model EL1SS).
2. Office building or gated residential community telephone entry systems (LiftMaster Model CAPXL Connected Access Portal - High Capacity).
3. Residential and light commercial telephone entry control system (LiftMaster Model EL25).
4. Commercial and gated community telephone entry system (LiftMaster Model EL2000).
C. Parking Control Systems:
1. High-performance, DC-powered barrier gate operator and accessories (LiftMaster Models MADCBB, MATDCBB).
2. High-speed, DC-powered barrier gate operator and accessories (LiftMaster Models MASDCBB, MASTDCBB).
1.2 RELATED SECTIONS
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
A. Section 03 30 00 - Cast-in-Place Concrete.
B. Section 26 05 00 - Common Work Results for Electrical.
C. Section 27 32 00 - Voice Communications Terminal Equipment.
D. Division 16 - Requirements for electrical connections.
1.3 REFERENCES
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
A. Underwriters Laboratories (UL):
1. UL 325 - Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems.
2. UL 991 - Standard for Tests for Safety-Related Controls Employing Solid-State Devices.
B. NFPA 70 - National Electrical Code.
C. FCC Regulations.
D. Canadian Department of Communications.
1.4 SUBMITTALS
A. Submit under provisions of Section 01 30 00 - Administrative Requirements.
** NOTE TO SPECIFIER ** Applicable to Access Control Systems and Telephone Entry Systems. Delete if not required.
B. Submittals:
1. Manufacturer's Data: Submit copies of the following:
a. Product data sheets and system description.
b. Installation instructions.
c. Authorized dealer certificate and certified training certificates of installers who will be working on this project.
** NOTE TO SPECIFIER ** Applicable to Access Control Systems. Delete if not required.
d. Block diagrams.
e. Equipment list.
2. Shop Drawings: Submit the following:
a. Access system layout and locations, including size requirements.
b. Detailed wiring diagrams of access equipment.
c. Load calculations of all equipment for proper sizing of electrical provided by the customer and standby emergency generator circuits.
** NOTE TO SPECIFIER ** Delete the following paragraph if not required by building owner.
3. As-Built Drawings: Update shop drawings to create final as-built drawings. Submit 3 copies and digitally in AutoCAD 14 or later format on a CD (3 copies).
4. Operation Data: Include 3 copies of the software administrator and operator manuals.
5. Maintenance Data: Include maintenance and repair procedures.
** NOTE TO SPECIFIER ** Applicable to Parking Control Systems. Delete if not required.
C. Submittals:
1. Product Data: Equipment list, system description, electrical wiring diagrams for installation, and manufacturer's data sheets on each product to be used, including:
a. Preparation instructions and recommendations.
b. Storage and handling requirements and recommendations.
c. Installation methods.
2. Shop Drawings: Submit shop drawings showing layout, profiles, and product components, including anchorage, edge conditions, and accessories.
a. Operation, installation, and maintenance manuals including wiring diagrams.
b. Risers, layouts, and special wiring diagrams showing any changes to standard drawings.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging with labels intact until ready for installation.
B. Schedule delivery of parking control equipment so that spaces are sufficiently complete that operators can be installed upon delivery.
** NOTE TO SPECIFIER ** Applicable to Access Control Systems. Delete if not required.
C. Owner will provide, on-site, a secure, dry, locked storage area for all equipment delivered under this scope of work.
1.6 QUALITY ASSURANCE
** NOTE TO SPECIFIER ** Applicable to Access Control Systems and Telephone Entry Systems. Delete if not required.
A. Quality Assurance:
1. Manufacturer: The access control system shall be from a single-source manufacturer that specializes in telephone entry control systems with a minimum of 5 years of experience.
2. Installer: Company specializing in access control systems with a minimum of 3 years of experience on systems of similar size and scope. Technicians working on project must have been certified on the hardware and software used for this project.
** NOTE TO SPECIFIER ** Applicable to Parking Control Systems. Delete if not required.
B. Assurance:
1. Perform installation by factory authorized contractor specifically trained in gate operation systems of the type found within this section.
2. Provide documentation of maintenance and repair service availability for emergency conditions.
3. Provide quarterly maintenance for 1 year following substantial completion of the project.
1.7 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
1.8 WARRANTY
A. Manufacturer's Standard Warranty:
** NOTE TO SPECIFIER ** Delete paragraphs for warranties not required.
1. Access Control System Warranty: 1 year limited warranty.
2. Telephone Entry System Warranty: 1 year limited warranty.
3. Telephone Entry/Access and Perimeter Control System: 2 years limited warranty.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: LiftMaster, which is located at: 300 Windsor Dr.; Oak Brook, IL 60523; Toll Free Tel: 800-282-6225; Fax: 630-516-8412; Email: request info (); Web: LiftMaster.com
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product Options and substitutions.
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
2.2 ACCESS CONTROL SYSTEMS
** NOTE TO SPECIFIER ** Install the LiftMaster Model KPR2000 on a LiftMaster pedestal and pair it with a LiftMaster gate or commercial door operator for a superior total entry control solution. Delete if not required.
A. Single Entry Access Keypad and Proximity Reader: LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader.
1. Performance:
a. Operating Voltage: 12V to 24V DC.
b. Current Draw: 25 mA idle; 60 mA peak.
c. Proximity Card Reader: HID 26-bit and 30-bit Wiegand format.
d. Industry standard 125 kHz.
e. Read Range - Proximity: 1 to 2-1/2 inches (25 mm to 64 mm).
f. Weatherization: Meets or exceeds IP68.
g. Operating Temperature: -4 degrees F (-20 degrees C) to 140 degrees F (60 degrees C).
h. Operating Humidity: 10% to 90% non-condensing.
2. Construction: Zinc-alloy enclosure.
3. Dimensions: Surface mount, 5 inches H x 3-1/5 inches W x 1-1/10 inches D (127 mm H x 81 mm W x 28 mm D).
4. Standard Features:
a. Stand-alone controller and pass-through mode.
b. Selectable ASCII keypad mode, or 26-bit card keypad mode.
c. Controls access for up to 2,000 users (card only, card or PIN, card and PIN).
d. Integrated alarm buzzer.
e. Additional alarm output (20A).
f. Rugged vandal-resistant backlit metal enclosure.
g. One programmable relay output (2A, form A).
h. Timed or latch mode to hold door/gate open (1 to 99 second timer).
i. Supports second keypad configuration for in and out same door or gate.
j. Block enrollment capability.
k. Program cards included for rapid programming.
l. Anti-tamper alarm (1 to 3 minute timer).
** NOTE TO SPECIFIER ** Delete accessories not required.
5. Accessories:
a. Low-Profile Access Pedestal (LiftMaster Model PED42).
b. High-Profile Access Pedestal (LiftMaster Model PED64).
c. 12V DC, 2A Power Supply (LiftMaster Model PS12D2A).
d. HID 26-Bit Proximity Card, or Key Fob.
e. HID 30-Bit Proximity Card, facility code 2 (LiftMaster Model SNACPH32).
f. HID 30-Bit Proximity Card, facility code 9 (LiftMaster Model SNACPH39).
g. HID 30-Bit Proximity Key, facility code 2 (LiftMaster Model SNACPKH32).
h. HID 30-Bit Proximity Key, facility code 9 (LiftMaster Model SNACPKH39).
** NOTE TO SPECIFIER ** Delete if not required.
B. Wireless Keypad Controls: LiftMaster KPW5 Wireless Access Control Keypad.
1. Standard Features:
a. Up to 5 access codes and 10 unique temporary PINs that can be set for 1 to 9 uses
b. Designed to work exclusively with Security+ 2.0.
c. Combines the simplicity of wireless installation with the robust feature sets of higher-priced keypad controllers.
d. High-impact polycarbonate front cover for rugged outdoor environment.
e. Electronics are fully sealed and meet NEMA 4X water protection requirements.
f. Allows for removal of a single PIN while maintaining full access for other users.
g. Up to 500-foot (152 m) range (open field).
h. Blue Backlit metal keypad for ease of use under low-light conditions.
2. Dimensions: Surface mount, 6 inches H x 4-3/10 inches W x 1-3/4 inches D (153 mm H x 109 mm W x 45 mm D).
3. Power: 9V Lithium battery.
4. Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
** NOTE TO SPECIFIER ** Delete if not required.
C. Wireless Commercial Keypad: LiftMaster KPW250 Wireless Access Control Keypad.
1. Standard Features:
a. Up to 250 access codes and 10 unique temporary PINs, that can be set for 1 to 9 uses..
b. Compatible with Security+ 2.0 and Security+, as well as Linear Multi-Code 300 MHz,
c. Combines the simplicity of wireless installation with the robust feature sets of higher-priced keypad controllers.
d. Zinc-alloy metal front cover for tough environments,
e. Electronics are fully sealed and meet NEMA 4X water protection requirements.
f. Allows for removal of a single PIN while maintaining full access for other users.
g. Up to 500-foot (152 m) range (open field).
h. Blue backlit metal keypad for ease of use under low-light conditions.
i. Keypad lighted when motion is detected.
2. Dimensions: Surface mount, 6 inches H x 4-3/10 inches W x 1-3/4 inches D (153 mm H x 109 mm W x 45 mm D).
3. Power: 9V Lithium batteries.
4. Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
** NOTE TO SPECIFIER ** Delete if not required.
D. Stand-Alone Keypad Access Control System: LiftMaster MINIkey Self-Contained Keypad System for Door and Gated Entrances.
1. Standard Features:
a. Control system shall be configured to allow either 4 or 5-digit codes activating the primary and/or auxiliary relay of the remote keypad when scheduled or required.
b. Lighted keypad.
c. Capacity: 500 names.
d. Relay Hold: Codes can be configured to latch relays open until they are unlatched by a second entry code to close.
e. Programmable Relay Times: Each relay independently programmable to activate from 2 to 255 seconds.
f. Time Clock: Access can be denied by preset times on dealer-supplied time clock.
g. Variable Entry Code Length: 4 or 5 digits.
h. Password Protection: Database information protected with 6-digit password.
i. Non-Volatile Memory: In event of power failure, database information is retained in memory allowing immediate start-up and operation when power is restored.
j. Strikes and Outs: Management specifies from 1 to 9 wrong entry codes entered consecutively before the system stops accepting codes for a 3-minute period.
k. Programming: Direct programming using built-in keypad.
l. Lightning Protection: Installer shall provide external surge suppressors in addition to surge protection inherent in the entry system.
** NOTE TO SPECIFIER ** Delete following paragraph if not required for Project.
2. Remote Keypad: For applications that require an entry and exit keypad, or for control of a secondary entry point, provides remote keypad unit that connects directly to the main unit.
3. Dimensions:
** NOTE TO SPECIFIER ** Retain one of the following two paragraphs. Coordinate with product selected above.