YM-SVE8X512
Foreword:
Thank you for choosing our LED controller family,make sure you have readthese instructions thoroughly before using the equipment.
The figures in the manual are for reference only. Our productswill becontinually updated, but the information may not be distributedindividually. The manual has been reviewed and the accuracy isguaranteed.
Use this manual Warnings
Do not disassemble or modify the product(may lead to electric shock, fire ormalfunction).
Do not use the product in places exposed to inflammable gases or debris such aspropane gas or gasoline (may causeexplosion or fire).
Do not use benzene or other volatile substances (may damage the product).
Keep away from direct sunlight. Do not storein high temperature areas (may cause productdeformation or malfunction).
Do not apply shock or impact to the product (may cause breakdown).
Do not install on an unstable location (may get detached and result in breakdown or injury).
Security Instructions:
Warning:Please install the controller in the environmentrecommended by our technicians, we do nottake any responsibilities forthe consequences of any damage caused by yourmis-operation.
Warning: Please double-check and make sure to use the powerwhich this controller isdesignated. Thewrong power may causeequipmentdamage or fire.
Warning:The lighting output ports providecontrol signals forthe lighting, pleasechoose and connect the cables and internet cablesas the manual recommended. And protect the power from the thunder andother outside powers in case leading malfunctionand equipmentdamage
Warning:Our controller firmware may be a little differentaccording to different control lightings. In order to make sure yourcontrollers can work as your designed goals please consult ourengineersif you choose the third-party lightings.
Importance:If your controller can not work after finishing allthe connecting. Do not try to disassemble the controller otherwise ourcompany will not stop providing the after-sales services.
Warning:Disassemble the controller while it is connected withthe power is dangerous, it may lead an electrical shock to you, or apermanent damage of controller circuit and controller components.
1、Parameters:
Model / Slave controller YM-SVE8X512Voltage / AC100V-230V
Power / 5W
Loading / 8X512=4096 pixels
Speed / 0.5—10M
Weight / 1.1kg
Temperature / -20—70 C°
Dimensions / 193*173*48mm
1.1、Port define:
1、Input port(IN):Connect master controller’s output port.
2、Output port(OUT):Connect next slaver’s input port.
3、port 1—8(Port): Connect LED lighting.
Note:Input port(IN)、output port(OUT) use CAT5E net cable.EIA/TIA 568B.
2、Schematic wiring:
2.1、Net cable:
As EIA/TIA568B。2 End of net cable in same order.
2.2、Signal define:
SPI signal DMXsignal
1st-Ground(GND) 1st-GND
2nd-Data(DAT) 2nd-D+
3rd-Clock(CLK) 3rd-D-
第1页
YUMING TECH.