WEIGH BELT/FEEDER Data Sheet / v  The completion of this engineering data sheet is necessary to correctly apply and design an accurate measurement system that meets all of your requirements. Please furnish all information requested below.
v  Please complete an Instrumentation Data Sheet to define your instrumentation/interface needs.
v  Please attach a free hand sketch of the application to this data sheet.
v  If you would like to conduct a material test, attach a Material Safety Data Sheet (MSDS) for each product to be tested. DO NOT FORWARD MATERIAL AT THIS TIME. You will be given a shipping address, required sample size and a Material Authorization Number after your MSDS sheet(s) have been reviewed and approved.
Company : / Contact :
Street Address : / Title :
P. O. Box : / Phone :
City : / Fax :
State : / E-Mail :
Zip/Postal Code : / Project Name :
Application:
Totalize Measure Feed Rate Control Feed Rate
Feed Rate (minimum) : 0.1 tph lb/hrlb/mingrams/hourgrams/minSTPHLTPHMTPH
Feed Rate (normal) : 0.2 tph lb/hrlb/mingrams/hourgrams/minSTPHLTPHMTPH
Feed Rate (maximum) : 2.0 tph lb/hrlb/mingrams/hourgrams/minSTPHLTPHMTPH
For rate control application preferred drive type is DC (SCR)AC (VFD)
Accuracy Required : 1/4% of of batch weightof design capacityof scale capacityof set rate / Batch
Batch Size (minimum) : lbsgramsshort tonslong tonsmetric tons
Batch Size (maximum) : lbsgramsshort tonslong tonsmetric tons
Batch Time : secondsminuteshours
Batch Frequency : batches per minutehourday
Material Specifications:
Ingredient Name : hydrated lime / Chemical Name :
Particle Size : -325 mesh inchmillimetermicron / Max. Lump Size : inchmillimetermicron
Bulk Density (Minimum) : lb/ft3kg/m3 / Specific Gravity :
Bulk Density (Maximum) : lb/ft3kg/m3 / Temperature : º FC
Moisture Content % : max min / Dry Damp Wet
Material Characteristics:
Abrasive / Dusty / Free Flowing / Packs Under Pressure
Adhesive / Explosive / Friable / Rat Holes
Bridges / Floodable / Hygroscopic / Toxic
Corrosive / Fragile / Interlocks & Mats / Similar to
Types of Feeders known to be suitable for handling material:
Belt / Vibratory / Screw / Rotary Vane

Weigh Belt/Feeder Data Sheet Page 1 of 2

THAYER SCALE, HYER INDUSTRIES, INC.

P. O. Box 669, 91 Schoosett Street, Pembroke, MA, USA 02359

Phone (781) 826-8101 • Fax (781) 826-7944

E-MAIL • WEBSITE http://www.thayerscale.com

WEIGH BELT/FEEDER Data Sheet / Process Flow:
Material is gravity fed through inchmillimeterfeetmeter wide x inchmillimeterfeetmeter long bin discharge opening.
Material is gravity fed through inchmillimetermicron diameter bin discharge opening.
Material is fed via apronbeltdrag conveyormetering tuberotary vanescrewtabletwin screwvibratory type pre-feeder, in-line withright angle to weigh belt. If right angle, width of pre-feeder is inchmillimeterfeetmeter.
Feeder discharges to:
Weigh Belt/Feeder Construction Requirements:
Construction Type: SanitaryNon-Sanitary / Paint: un-paintedindustrial enamelindustrial epoxy Paint Tint (RAL):
Materials of Construction; / Frame: carbon steel304 stainless steel304L stainless steel316 stainless steel316L stainless steel / Contact Parts: abrasion resistantcarbon steel304 stainless steel304L stainless steel316 stainless steel316L stainless steel
Enclosure Requirements: OpenFixed top, open sides, ends and bottomFixed top,removable side & end panels, open bottomTotally enclosed with drag scavngerTotally enclosed with drop bottom doorsTotally enclosed with fixed bottomTotally enclosed with scavenger screw
Design Pressure Rating: atmosphericcentimeters of Hg @ 0o Ccentimeters of H2O @ 4o Cinches of Hg @ 32o Finches of H2O @ 39.2o Fkg/cm^2gpounds per square inch / Design Vacuum Rating: atmosphericcentimeters of Hg @ 0o Ccentimeters of H2O @ 4o Cinches of Hg @ 32o Finches of H2O @ 39.2o Fkg/cm^2gpounds per square inch
Dust Take-Off: not requiredat dischargeat inletat inlet and discharge / Belt Cleaner: not requiredfixed blade

feetinchesmeters
Installation Notes:
Ambient Temperature range: º FC to º FC / Location is: indoorsoutdoors
Electrical Area Classification for weigh belt/feeder : Non-Hazardous (unclassified)
Class IIIIII, Division 12, Group A & BC & DE, F & G and
Class IIIIII, Division 12, Group A & BC & DE, F & G
Electrical Area Classification for drive : Non-Hazardous (unclassified)
Class IIIIII, Division 12, Group A & BC & DE, F & G and
Class IIIIII, Division 12, Group A & BC & DE, F & G
Electrical Area Classification for instrument : Non-Hazardous (unclassified)
Class IIIIII, Division 12, Group A & BC & DE, F & G and
Class IIIIII, Division 12, Group A & BC & DE, F & G
Power available for motor/drive : VAC, Phase, Hz