2016 Post #6 BIO PAK 240 R Written Test
Contestants Name: ______Team Name: ______
- Prior to using the BioPak 240 Revolution it must be determined that the user is ______fit.
physicallymentallymedically
- Do not open the cylinder valve in the presence of open flame, ______or high radiant heat.
sparksoillow
3.The use of an SCBA will add to the workload and stress of the ______.
weareruserperson
4.A foreign _____ may cause cylinder corrosion.
bodygasobject
5.DOT requires carbon fiber wrapped aluminum cylinders be tested by an approved facility on a __-year cycle from the date of manufacture.
2105
6.The fiber optic cable may only be ______to the BioPak 240R remote gauge assembly.
attachedconnectedassembled
7.______after completion of BioPak use, remove the used CO2 scrubber canisters.
soon shortlyimmediately
8.Use only ______and disinfectants that are approved by Bio marine.
cleanerscleanserssoaps
9.Remove the oxygen cylinder making sure the seal ______remains in place and install the regulator cover.
gasketo-ringwasher
10.C.O.P.D. could limit or ______the use of the BioPak 240 Revolution.
prohibit limitprevent
11.The manual(s) are the ______recommended procedures for maintaining the BioPak 240R.
maximumminimumspecific
12.To ______mold growth remove the moisture control foam pads after each use.
limitprevent prohibit
13.Pre-packing the BioPak 240 R with carbon dioxide scrubbers is only permitted when utilizing ______carbon dioxide scrubber.
factoryrefillableOrbsorb
14.Pre-packed carbon dioxide scrubbers may only be stored in the ______for a maximum period of 1-year.
containersapparatusboxes
15.Users are not permitted to mix ______of the Orbsorb within a BioPak.
versionscontainerstypes
16.The oxygen cylinder must be fully charged to above _____ psi to perform a high pressure leak test.
260030001500
17.The Cylinder should be ______regularly for signs of damage to the outer wrapping.
checked inspected tested
18.Never pry an O-ring from its glands with a ______. Remove O-rings by hand or with the pick tool provided in the service kit.
wrenchscrewdriverpry-bar
19.Cristo-Lube and Dow-111 are the only ______approved for use in the apparatus.
lubricantschemicalspastes
20.The Alarm module will require ______if any damage to the housing is discovered.
servicingattentionreplacement
Identification of Parts
21.Item # 3 of the upper housing assembly drawing
green knoboxygen knob external oxygen knob
22.Item # 7 of the upper housing drawing
spacer barvent spacervent valve spacer
23. Item #12 of the upper housing drawing
foam padvibration padlatch foam pad
24. Item # 18 of the upper housing drawing
Hold down straphold down gripcarrying handle
25. Item # 1 of the Pneumatic Assembly
supply lineoxygen supply linebypass feed tube
26.Item # 2 of the Pneumatic Assembly
bypass linebypass return tubesupply line
27.Item # 6 of the Pneumatic Assembly
bypass valve buttonbypass valve push button bypass valve
28.Item # 9 of the Pneumatic Assembly
Oxygen regulator assemblyregulator assemblyregulator
29. Item # 3 of the Center Section Lid Assembly
scrubber holderscrubber braceflow baffle
30. Item #4 of the Center Section Lid Assembly
Metal screwself-tapping screwsstainless screw
2016 BIO PAK 240 R Written Test Answers
- medically17. inspected
- sparks18. screwdriver
- user19. lubricants
- Gas20. replacement
- 5
- connected
- immediately
- cleaners
- washer
- prevent
- minimum
- prevent
- Orbsorb
- apparatus
- versions
- 1500
2016 BIO PAK 240 R Identification of Parts Answers
21.external oxygen knob
22.vent spacer
23. latch foam pad
24.carrying handle
25. bypass feed tube
26. bypass return tube
27.bypass valve push button
28. oxygen regulator assembly
29. flow baffle
30.self-tapping screws