VTIndustries, Inc.December 2017

1000IndustrialPark

POBox490

Holstein,Iowa51025

TollFree(800)827-1615

Phone(712)368-4381

Fax(712)368-4111

Website

ProductGuideSpecification

SpecifierNotes:ThisproductguidespecificationiswrittenaccordingtotheConstructionSpecificationsInstitute(CSI)3-PartFormat,includingMasterFormat,SectionFormat,andPageFormat,asdescribed inTheProjectResourceManual—CSIManualofPractice.

ThesectionmustbecarefullyreviewedandeditedbytheArchitecttomeettherequirementsoftheprojectandlocalbuildingcode.CoordinatethissectionwithotherspecificationsectionsandtheDrawings.Deleteall“SpecifierNotes”wheneditingthissection.

SectionnumbersarefromMasterFormat1995Edition,withnumbersfromMasterFormat2004Editioninparentheses.Deleteversionnotrequired.

SECTION08216(081433) STILEANDRAILWOODDOORS

SpecifierNotes:ThissectioncoversVTIndustriesHeritageCollectionarchitecturalinteriorstileandrailwooddoors.ConsultVTIndustriesforassistanceineditingthissectionforthespecificapplication. Visit

PART1GENERAL

1.1SECTIONINCLUDES

A.Architecturalinteriorstileandrailwooddoors.

1.2RELATEDSECTIONS

SpecifierNotes:Editthefollowinglistofrelatedsectionsasrequiredfortheproject.Listothersectionswithworkdirectlyrelatedtothissection.

A.Section06460(064800)–WoodFrames.

B.Section08100(081200)–MetalFrames.

C.Section08710(087100)–DoorHardware.

D.Section08800(088000)–Glazing.

1.3REFERENCES

SpecifierNotes:Liststandardsreferencedinthissection,completewithdesignationsandtitles.Deletestandardsnotusedinthissection.Thisarticledoesnotrequirecompliancewithstandards,butismerelyalistingofthoseused.

A.NFPA80–StandardforFireDoorsandOtherOpeningProtectives.

B.WindowandDoorManufacturersAssociation:

1.I.S.6-A-11–IndustryStandardsforArchitecturalWoodStileRailDoors.

2.TR-2–FactoryFinishCatalyzedLacquer.

1.4SUBMITTALS

A.ComplywithSection01330(013300)–SubmittalProcedures.

B.ProductData:Submitmanufacturer'sproductdata.SpecifierNotes:Editthefollowingsentenceasrequired.

C.ShopDrawings:Submitmanufacturer'sshopdrawings,includingelevations,sections,anddetails, indicatingdoorconstruction,dimensions,tolerances,materials,[panels,][hardware,][glass,] [louvers,]andfinish.

D.Samples:

1.Doors:Submitmanufacturer'ssampleofdoorsshowingmaterialsandfinish.

2.Color:Submitmanufacturer’sdoorfinishsamples,showingrangeofcolorvariation.

E.Manufacturer’sCertification:Submitmanufacturer’scertificationthatdoorscomplywithspecifiedrequirementsandaresuitableforintendedapplication.

F.CleaningInstructions:Submitmanufacturer'scleaninginstructionsfordoors.

G.Warranty:Submitmanufacturer'sstandardwarranty.

1.5QUALITYASSURANCE

A.IdentifyingLabel:Eachdoorshallbearidentifyinglabelindicating:

1.Doormanufacturer.

2.Ordernumber.

3.Doornumber.

4.Firerating,ifapplicable.

SpecifierNotes:Deletethefollowingparagraphiffire-rateddoorsarenotrequired.

B.Fire-RatedDoors:LabeledbyIntertek/WarnockHersey.

1.ConstructionDetailsandHardwareApplication:Approvedbylabelingagency.

1.6DELIVERY,STORAGE,ANDHANDLING

A.Delivery:

1.Deliverdoorstositeinmanufacturer’soriginal,unopenedcontainersandpackaging,withlabelsclearlyidentifyingproductnameandmanufacturer.

B.Storage:

1.Storedoorsinaccordancewithmanufacturer’sinstructions.

2.Storedoorsinclean,dryareaindoors,protectedfromdamageanddirectsunlight.

3.Storedoorsflatonlevelsurface.

4.Donotstoredoorsdirectlyonconcrete.

5.Keepdoorscompletelycovered.Usecoveringwhichallowsaircirculationanddoesnotpermitlighttopenetrate.

6.Storedoorsbetween50and90degreesF(10and32degreesC)and25to55percentrelativehumidity.

7.Donotsubjectdoorstosuddenchangesintemperatureorrelativehumidity.

C.Handling:

1.Handledoorsinaccordancewithmanufacturer’sinstructions.

2.Protectdoorsandfinishduringhandlingandinstallationtopreventdamage.

3.Handledoorswithcleanhandsorcleangloves.

4.Liftandcarrydoors.Donotdragdoorsacrossotherdoorsorsurfaces.

1.7WARRANTY

A.Warrantinteriordoorsfor5yearsininterioruseagainstwarpage,delamination,anddefectsinmaterialsandworkmanship.

B.DefectsnotedduringwarrantyperiodshallbecorrectedatnocosttoOwner.Correctiveworkshall includelaborandmaterialforrepair,replacement,refinishing,andrehangingasrequired.

PART2PRODUCTS

2.1MANUFACTURER

A.VTIndustries,Inc.,1000IndustrialPark,POBox490,Holstein,Iowa51025.TollFree(800)827-1615.Phone(712)368-4381.Fax(712)368-4111.

2.2STILEANDRAILWOODDOORS

A.ArchitecturalInteriorStileandRailWoodDoors:HeritageCollection.

SpecifierNotes:SpecifyHeritageCollectiondoorseriesandmodels.ConsultVTIndustriesforHeritageCollectioncustomstileandraildoors.

1.1000Series,WoodPanels:Model[1011H][1021H][1031H][1032H][1041H][1042H][1051H][1052H][1061H][1062H][1063H][1081H][1091H].

2.3000Series,GlassPanels:Model[3011H][3021H][3022H][3024H][3032H][3041H][3042H][3052H][3061H][3062H][3063H][3081H][3091H][3101H][3121H][3151H][3181H].

3.5000Series,WoodandGlassPanels:Model[5021H][5031H][5041H][5071H][5101H][5111H][5131H][5141H].

4.7000Series,LouverPanels:Model[7011H][7021H].

5.9000Series,WoodandLouverPanels:Model[9021H][9022H].

6.Customelevations.

SpecifierNotes:Specifycustomgradeconstruction.Customgradeisstandard.

B.Compliance:WDMAI.S.6-A-11,customgrade.

C.Design:

SpecifierNotes:Specifypaneltype.

1.PanelType:[Flat][Raised][Glass][Louver] [ Step]

2.SpecifierNotes:Specifydoortop.

3.DoorTop:[Square][Arch][Radius].SpecifierNotes:Specifytoppanel.

4.TopPanel:[Square][Arch][Colonial][Radius].

D.Non-RatedDoorsand20-MinuteFireDoors:HeritageCollection.

SpecifierNotes:SpecifydimensionsforHeritageCollectionnon-rateddoorsand20-minutefiredoors.Refertomanufacturer’sproductlistingforapprovedcomponentdimensions.

1.DoorThickness:1-3/4inches.

2.StileWidth:6inches,unlessotherwisenoted.

3.MullionWidth:3-5/8”inches,unlessotherwisenoted.

4.Rails:

a.TopRailWidth:6inches,unlessotherwisenoted.

b.LockRailWidth:8-3/4inches,unlessotherwisenoted.

c.CrossRailWidth:3-5/8”inches,unlessotherwisenoted.

d.BottomRailWidth:10inches,unlessotherwisenoted.

5.Panels:

SpecifierNotes:Specifythicknessforflatorraisedpanels.

a.FlatPanelThickness:5/8inch.

b.RaisedPanelThickness:1-1/8inches.

SpecifierNotes:Deleteglassifnotspecified.DoorsmaybefactoryglazedorfieldglazedasdeterminedbytheContractor.

6.Glass:

a.Type:.

b.Thickness:.

SpecifierNotes:Specifytypeoflouvers.Deletelouversifnotspecified.

7.Louvers:[Chevron][Flatslat][].

SpecifierNotes:Specifybar/muntinwidthandthicknessfor3000and5000Seriesdoorsonly.

8.Bar/Muntin:

a.Width:1/2inch.

b.Thickness:1-3/4inches.

9.Veneers:

SpecifierNotes:Specifythefaceveneerspeciesandcut.

a.Species:.

b.Cut:[Rotary][Plainsliced][Quarter][].

F.45-,60-,and90-MinuteFire-RatedDoors:HeritageCollection.

SpecifierNotes:SpecifydimensionsforHeritageCollection45-,60-,and90-minutefire-rateddoors.Refertomanufacturer’sproductlistingforapprovedcomponentdimensions.

1.DoorThickness:1-3/4inches.

2.StileWidth:6inches.

3.MullionWidth:3-5/8”inches.

4.Rails:

a.TopRailWidth:6inches.

b.LockRailWidth:8-3/4inches.

c.CrossRailWidth:3-5/8”inches.

d.BottomRailWidth:10inches.

5.Panels:

SpecifierNotes:Specifythicknessforflatorraisedpanels.

a.FlatPanelThickness:7/8inch.

b.RaisedPanelThickness:1-11/32inches.

c.MinimumPanelSize:11-1/2inchesby11-1/2inches.

6.FireLabels:Attachpermanentfirelabelonhingestileofeachfire-rateddoor.

2.3DOORCONSTRUCTION

A.StileEdge:Matchinghardwoodstileedge.

B.InnerStileandRail:

1.Non-RatedDoorsand20-MinuteFire-RatedDoors:Specifiedwoodveneerpressedoverstructuralcompositelumber.

2.45-,60-,and90-MinuteFire-RatedDoors:Specifiedwoodveneerpressedovernoncombustiblematerial.

C.Panels:

1.Specifiedwoodveneerpressedovermedium-densityfibercore.

2.Specifiedwoodveneerpressedoverfire-retardantcore.

D.StileandRailJoints:Doweledconstruction.

E.HingesandFacePlates:Factorydrillpilotholes.

SpecifierNotes:Specifystickingusedwithpanels,louvers,orglass.

F.StickingUsedwith[Panels][Louvers]or[Glass]:[Ovolo][Square][Ogee].

2.4HARDWARE

A.Factorymachinedoorsinaccordancewithtemplatesfromspecifiedhardwaremanufacturersand hardwareschedule.

2.5FINISH

A.StileandRailDoors:Manufacturer’sfactoryfinish.

B.FactoryFinish:VTIndustriesfactoryfinish.

1.Description:WDMATR-2catalyzedlacquersystem.

SpecifierNotes:Specifystaincolor,unlessclearfinishisrequired.ConsultVTIndustriesforavailabilityofcustomstaincolors.Aminimum3-inchby5-inchphysicalsampleisrequiredforcustomcolormatching.

a.ClearFinish:Clear.

b.StainColor:[Alpine][Grassland][Oasis][Ravine][Savanna][Timber][Wheat].

c.Primeforopaquefinisheddoors.

2.SealersandTopcoats:pre-catalyzedlacquer.

C.TopandBottomRails:Factorysealed.

PART3EXECUTION

3.1EXAMINATION

A.Examinelocationstoreceivedoors.NotifyArchitectofconditionsthatwouldadverselyaffectinstallationorsubsequentuse.Donotbegininstallationuntilunacceptableconditionsarecorrected.

B.Ensureframesaresolidlyanchored,allowingnodeflectionwhendoorsareinstalled.

C.Ensureframesareplumb,level,square,andwithintolerance.

3.2PREPARATION

A.Allowdoorstobecomeacclimatedtobuildingtemperatureandrelativehumidityforaminimumof24 hoursbeforeinstallation.

3.3INSTALLATION

A.Installdoorsinaccordancewithmanufacturer’sinstructions.SpecifierNotes:Editthefollowingsentenceasrequired.

B.Installdoorsatlocationsindicatedonthe[DoorSchedule][Drawings].

C.Installdoorsplumb,level,andsquare.

D.InstalldoorhardwareasspecifiedinSection08710(087100).

3.4ADJUSTING

A.Adjustdoorstoswingfreely,withoutbindinginframe.

B.Adjusthardwaretooperateproperly.

C.Repairminordamagestofinishinaccordancewithmanufacturer’sinstructionsandasapprovedby Architect.

D.Removeandreplacedamageddoorsthatcannotbesuccessfullyrepaired,asdeterminedbyArchitect.

3.5CLEANING

A.Cleandoorspromptlyafterinstallationinaccordancewithmanufacturer’sinstructions.

B.Donotuseharshcleaningmaterialsormethodsthatcoulddamagefinish.

3.6PROTECTION

A.Protectinstalleddoorsfromdamageduringconstruction.

ENDOFSECTION