NanaWall® SL70- Monumental,ThermallyBrokenAluminumFramedFolding
PanelSystem
PART1-GENERAL
1.01 SUMMARY
A. SectionIncludes:Sliding/foldingaluminumandglassdoorsystem,includingaluminumframe,threshold,panels,sliding/ foldingandlockinghardware,weatherstripping,glassandglazing;designedtoprovideanopeningglasswall,withsizesand configurationsas shownon drawingsandspecifiedherein,NanaWall® SL70,MonumentalThermallyBrokenAluminumFramed Folding PanelSystemassuppliedbyNanaWallSystems,Inc.
1.02 REFERENCES
A. AmericanArchitecturalManufacturersAssociation(AAMA):
1.AAMA520,VoluntarySpecificationforRatingtheSevereWind-DrivenRainResistanceofWindows, DoorsandUnitSkylights
2.AAMA611,VoluntarySpecificationforAnodizedArchitecturalAluminum.
3.AAMA1304,VoluntarySpecificationsforForcedEntryResistanceofSide-HingedDoorSystems.
4.AAMA2604,VoluntarySpecifications,PerformanceRequirementsandTestProceduresforHighPerformance
OrganicCoatingsonAluminumExtrusionsandPanels.
5.AAMA2605,VoluntarySpecifications,PerformanceRequirementsandTestProcedures forSuperiorPerforming
OrganicCoatingsonAluminumExtrusionsandPanels. B. AmericanSocietyforTestingandMaterials(ASTM):
1.ASTME283,TestMethodforRateofAirLeakagethroughExteriorWindows,CurtainWalls,andDoorsby
UniformStaticAirPressureDifference.
2.ASTM E330,TestMethodforStructuralPerformanceofExterior Windows,CurtainWalls, andDoors byUniform
StaticAirPressureDifference.
3. ASTME331,StandardTestMethodforWaterPenetrationofExteriorWindows,Skylights,Doors,andCurtain
WallsbyUniformStaticAirPressureDifference.
4.ASTME547,TestMethodforWaterPenetrationof ExteriorWindows,CurtainWalls,and DoorsbyCyclicStatic
AirPressureDifferential.
5.ASTME2268, StandardTest MethodforWaterPenetrationofExteriorWindows,Skylights,andDoorsbyRapid
PulsedAirPressureDifference
6.ASTMF 842,StandardTestMethodsforMeasuringtheForcedEntryResistanceofSlidingDoorAssemblies. C. AmericanNationalStandardsInstitute(ANSI):
1.ANSIZ97.1,SafetyPerformanceSpecificationsandMethodsofTestforSafetyGlazingMaterialUsedInBuild- ings.
D. ConsumerProductSafetyCommission(CPSC):
1.CPSC16CFR-1201,SafetyStandardforArchitecturalGlazingMaterials. E. NationalFenestrationRatingCouncil(NFRC):
1.NFRC100,ProcedureforDeterminingFenestrationProductThermalMaterials.
2.NFRC200,ProcedureforDeterminingSolarHeatGainCoefficient.
3.NFRC400,ProcedureforDeterminingFenestrationProductAirLeakage.
1.03 SUBMITTALS
A. DetailDrawings: Indicatedimensioning,directionofswing,configuration,swingpanels,typicalheadjamb,side jambsandsilldetails,typeofglazingmaterialandhandleheight.
B. ProductData:Manufacturer’s literatureincludingindependentlytesteddatalistingperformancecriteriaandOwner’s
Manualwithinstallationinstructions.
C. ContractCloseoutSubmittal: SubmitOwner’sManualfrommanufacturer. Identifywithprojectname,locationand completiondate,typeandsizeofunitinstalled.
1.04QUALITYASSURANCE
A. Manufacturer: Provide complete,precisionbuilt,engineered,pre-fittedunitbyasinglesourcemanufacturerwithat least25yearsexperience inprovidingfolding/slidingdoorsystemsforlargeopeningsintheNorthAmericanmarket.
1. ThemanufacturermusthaveaqualitymanagementsystemregistrationtotheISO9001:2008standard.
B. PerformanceCriteria:Providefrommanufacturerthathasindependentlytestedtypicalunitswiththefollowing minimumresults.
1.Airinfiltration: Providesystemwithmaximumairleakageof0.30cfm/sqftwhentestedaccordingtoASTME
283andNFRC400atastaticairpressuredifferenceof1.57psfand 6.24psf.
2.WaterPenetrationunderStaticPressure:
a. Providesystemwitharaisedsill(inswingoroutswing)thatdonotevidencewaterpenetrationwhen testedaccordingtoASTME 331andASTME547atastaticairpressuredifferenceof12psf.
b. Providesystemwithasaddlesillwithtypicalfieldinstalledweepholesanddrainagebyothers(see drainageinstructionsfromNanaWall)thatdo notevidencewaterpenetrationwhentestedaccordingto ASTM E331andASTME547atastaticairpressuredifferenceof5.25psfforaninswingunitand6.00psfforan outswingunit.
3.WaterPenetrationunderDynamicPressure:Providesystemwitharaisedsillthatdonotevidencemorethan allowablewaterentrywhentestedaccordingtoAAMA520andASTME 2268ata dynamicratedairpressure differenceof 6-18psffor an inswingunit(PerformanceLevel2) and5-15psffor an outswingunit(Performance Level1).
4.StructuralTestPerformance:
a.ProvidesystemwithoptionalreinforcedpoststhatwhentestedaccordingtoASTME330at150%ofpositive andnegativedesignpressureswithpanelsizesof3’wideand8’highachievedwithaninswingunitwitha raisedsill DPratingof +70psf/-100psfandan outswingunitwitharaisedsill andinswing/outswingunitswith saddlesillsDPratingsof+/-70psf.
b. ProvidestandardsystemthatwhentestedaccordingtoASTME330at150%ofpositiveandnegative designpressureswithpanel sizesof2’11”wide and8’1”highachievedwithaninswingunitwitharaisedsillDP ratingof+55 psf /-90 psf, anoutswingunit witharaisedsillDP ratingof-90 psf /+55psf andinswing/outswing unitswithsaddlesillsDPratingsof+/-50psf.
5.ForcedEntryResistance: ProvidesystemthatwhentestedaccordingtoASTMF842andAAMA1304there wasnoentry.
SPECIFIERNOTE:Airinfiltrationandwaterpenetrationtestingresultscanonlybeapplicableiftheunit matchesthetestunitinthedirectionofopeningandthetypeofsill.Structuralloadtestingresultsareonly applicableforthetestunitsize.(Comparativeanalysischartsforunits publishedbymanufacturershowwhich panelsizes(ifany)wouldmeetthestructuralloadingdesignpressuresspecificallyrequiredfortheproject. Checkforlimitationsontheuseofthesechartsinthejurisdictionoftheproject).Seemanufacturer’slatest publisheddata.]
C. ThermalPerformanceUfactor:Unittoberated,certifiedandlabeledinaccordancewithNFRC100,shownin manufacturer’slatestpublisheddatafortheglazing,sill,anddirectionofopeningspecified.
D. SolarHeatGainCoefficient:Unittoberated,certifiedandlabeledinaccordancewithNFRC200,showninmanufac- turer’slatestpublisheddatafortheglazing,sill,anddirectionofopeningspecified.
SPECIFIERNOTE: Ifdesired,EnergyStarratingscanbeachievedbytheuseofproperglasswiththeunit. SeeNanaWall’sPerformancedatafordetails.
E. InstallerQualifications: Installerexperiencedin theinstallationof manufacturer’sproductor othersimilarproducts forlargeopenings.Installertoprovidereferencelistofatleast3 projectsof similarscaleand complexitysuccess- fullycompletedinthelast3years.
1.05WARRANTY
A. Providemanufacturer’sstandardwarrantyagainstdefectsinmaterialsandworkmanship.
B. WarrantyPeriod:Tenyearsforrollers.Forallothercomponents,oneyear(twoyearsifunitisinstalledbymanufac- turer’scertifiedtrainedinstaller)fromdateofdeliverybymanufacturer.
PART2–PRODUCTS
2.01SUPPLIER
A. NANAWALLSYSTEMS,INC.
100 Meadow Creek Drive, Corte Madera, CA 94925
TollFree:(800)873-5673
Telephone:(415)383-3148
Fax:(415)383-0312
Website:
Email:
2.02MATERIALS
A. FrameandPanels:From manufacturer’sstandardprofiles,provideheadtrack, sidejambs,andpanelswithdimen- sionsshownondrawings.
1.Providepanelswith: Standardonelite
[ORwithhorizontalmullion(s)atspecifiedheight(s)fromthebottomofthepanel] [ORwithsimulateddividedlitesinpatternasshownondrawings]
2.Providestandardbottomrail[ORmanufacturer’sstandardkickplatewithheightspecified].
3.AluminumExtrusion: Extrusionswithnominalthicknessof.078”(2.0mm). AlloyspecifiedasAIMgSi0.5with strengthratedas6063-T5orF-22(Europeanstandard).AnodizedconformingtoAAMA611,powdercoated conformingtoAAMA2604orfluoropolymarkynarpaintedconformingtoAAMA2605.
4.Thermallybrokenwith¾”-15⁄16”(20-24mm)polyamideplasticreinforcedwithglassfibers.Polyamideplastic lessthan3/4"(20mm)wideorpourandde-bridgethermalbreakwillnotbeaccepted.
5.AluminumFinish:
SelectfromNanaWallPowderCoatingFinishChart
[ORclearanodized]
[ORdarkbronzeanodized]
[ORselectfromrangeofRALhighglosspowdercoatedfinishesavailablefrommanufacturer] [ORselectfromrangeofRALmattepowdercoatedfinishesavailablefrommanufacturer]
[ORWoodGrainpowdercoatedfinish]
[ORselectfromrangeofflouropolymarkynarpaintedfinish] [ORcustomfinish].
Same[ORdifferent]finishesoninsideandoutside. B. Glass:
1.AllglasstocomplywithsafetyglazingrequirementsofANSIZ97.1andCPSC16CFR1201.Providemanufac- turer’sstandardglasswithdryglazingwithglassstopsontheinsideonly:
15/16”(24mm)doubleinsulatedclearsafety
[OR15/16”(24mm)doubleinsulatedargonfilledLow-Esafety]
[OR11/2”(38mm)doubleinsulatingkryptonfilledtwolayersHeatMirrorTC88safety] [OR11/2”(38mm)tripleinsulatedargonfilledLowEsafety]
[OR11/8"(28mm)OrniluxBirdSafeGlass]
[ORotherglassavailablefrommanufacturer,includingglasswithothertotalthickness].
2.Providemanufacturer’sstandardsilvergray[ordark bronze]glassspacers. Providewithoutcapillarytubes[OR
withcapillarytubes].
C. LockingHardwareandHandles:
1.Mainentrypanel:
Onthemainentrypanelformodelswithapairofswingpanels,providemanufacturer’sstandardleverhandles ontheinsideandoutside,aSchlagecompatiblelocksetwithlockablelatch,multi-pointlockingwithadead bolt androdsatthetopandbottomonprimarypanel. Rodstobeconcealedandnotedgemounted. After
turnofkeyorthumburn,depressionofhandleswithdrawslatch. Liftingofhandlesengagesrodsandturnof keyorthumbturnengagesdeadboltandoperateslock. Onthesecondaryswingpanel,providematching dummyleverhandlesonbothsidesandconcealedflushboltsthatoperatestherodsatthetopandthebottom forthesecondaryswingpanel.
Stainlesssteelleverhandlesinatitaniumblackfinish
[ORstainlesssteelleverhandlesinabrushedsatinfinish] [ORoil rubbedbronzesolidbrassleverhandles]
[ORsatinnickelsolidbrassleverhandles] [ORwhitesolidbrassleverhandles]
[ORonthemainentrypanelformodelswithaswingpanel,providemanufacturer’sstandardleverhandleson theinsideandoutside,aSchlagecompatiblelocksetwithlockablelatch,multi-pointlockingwithadeadbolt and rodsatthetopand bottomonprimarypanel only. Rodstobeconcealedand notedge mounted. Afterturn of key or thumbturn,depressionof handleswithdrawslatch. Liftingof handlesengagesrodsandturnof keyor thumbturnengagesdeadboltandoperateslock.Ifthereisasecondaryswingpanel,providetwo pointlocking withUshapedhandlesoninsideonlyforthesecondaryswingpanel.]
Stainlesssteelleverhandlesinatitaniumblackfinish
[ORstainlesssteelleverhandlesinabrushedsatinfinish] [ORoil rubbedbronzesolidbrassleverhandles]
[ORsatinnickelsolidbrassleverhandles] [ORwhitesolidbrassleverhandles]
[ORonthemainentrypanelformodelswithaswingpanel,providemanufacturer’s push/pullhandleswithseparate locksetanddeadboltandonepointlockingatthetopandbottomconsistingoflockingrodsoperatedbya 180º turnofaflathandlesontheinside]
Push-pullhandlesinabrownnylonfinishandstainlesssteelflathandlesinatitaniumblack
finish
[ORpush-pullhandlesinagray nylonfinishandstainlesssteelflathandlesinabrushedsatin
finish]
[ORpush-pullhandlesina whitenylonfinishandstainlesssteelflathandlesina brushedsatin
finish]
SPECIFIER’SNOTE:This optionisrecommendedwith adoorcloser,butnotethat inordertoslidetheswing panel,thedoorcloserwillneedtobedisengagediftheswingpanelisnotattachedtoasidejamb.]
[ORonthemainentrypanelformodelswithaswingpanel,nohardwareorlockingtobeprovided bythemanufacturer,butwithfieldinstalledpanicdevicebyothers.]
[ORonbothentrypanelsformodelswithapairofswingpanels,nohardwareorlockingto
beprovidedbythemanufacturer,butwithfieldinstalledpanicdevicesonbothpanelsbyothers.] SPECIFIER’SNOTE: Structuraltestloadresultswillnotapplyforlockingdevicesbyothers.
[ORonmainentrypairofpanelsonmodelswithoutaswingpanel,providemanufacturer’sstandard
L-shapedhandlesontheinsideandontheoutsideandlockset withprofilecylinder. Operationof lock setisbyturnofkeyfromtheoutsideandwithathumbturnfromtheinsidewithatwopointlocking hardwareoperatedby180ºturnofthehandle.]
StainlesssteelLshapedhandlesinatitaniumblackfinish
[ORstainlesssteelLshapedhandlesinabrushedsatinfinish] [ORLshapedhandlesinabrownnylonfinish]
[ORLshapedhandlesinagraynylonfinish] [ORLshapedhandlesinawhitenylonfinish
[ORon mainentrypanel,providemanufacturer’sstandardU/L shapedhandleon insideonlywith concealedtwopointlockinghardwareoperatedby180degreeturnofhandle.
SPECIFIER’SNOTE: Notethatwiththisoption,themainentrypanelisoperablefrominsideonlyandthat thereisnolatch.]
SPECIFIER’SNOTE: Notethatothercompatiblelever,Lshapedandpush-pullhandlestylesandfinishes areavailablefromothersuppliers.
2.On allothersecondarypanelsand pairsoffoldingpanels,providemanufacturer’sstandardhandles[ORremov- ablecustodialhandles]andconcealedtwopointlockinghardwareoperatedby180degreeturnofhandlebetween eachpair. Faceappliedflushboltlockingwillnotbeallowed. Standardhandlefinish:
Stainlesssteelstandardhandlesinatitaniumblackfinish
[ORStainlesssteelstandardhandlesinabrushedsatinfinish] [ORstandardhandlesinabrownnylonfinish]
[ORstandardhandlesinagraynylonfinish] [ORstandardhandlesinawhitenylonfinish]
3.Providehandleheightcenteredat41⅜”[ORasspecified]frombottomofpanel.
4.Aluminumlockingrodswithstandardfiberglass reinforcedpolyamideendcapsattopandbottom.Rods tohave astrokeof15⁄16”(24mm).
5.Iftherearemorethanoneunit,keyedalike[ORkeyeddifferently].
D.Sliding/FoldingHardware:Providemanufacturer’sstandardcombinationslidingand foldinghardwarewith top, bottomtracksandthreshold. Allrunningcarriagestobewithsealed,self-lubrication,ballbearingmulti-rollers. Surfacemountedhingesandrunningcarriageswill notbeallowed. Weightof panelsto bebornebythe bottomof theguidechannelin thesillwillnotbeallowed.
1.Provideupperguidecarriageandlowerrunningcarriagewithfourverticalstainlesssteelwheelsandtwohorizon-
talpolyamidewheels.Theverticalwheelstorideontopofstainlesssteelguidetrackcoversoverthefulllength of thesilltrackandlie abovethewaterrun-offlevel. Carryingcapacityof lowerrunningcarriageto be440lbs (200kgs). Wheelsridingbelowthewaterrun-offleveland/orwheelsridingonaluminumsurfaceswill notbeallowed.
2.Threshold:
Providethermallybrokenwithpolyamideraisedsillinthesamefinishaspanelfinish
[ORclearanodizedlowprofilesaddlesill]
[ORdarkbronzeanodizedlowprofilesaddlesill] [ORclearanodizedflushsill]
[ORdarkbronzeanodizedflushsill]
[ORclearanodizedSurfaceMountedInteriorSill] [ORbronzeanodizedSurfaceMountedInteriorSill]
A coverplateoverthesillwillnotbeallowed.
3.Hinges:Zincdie castwithfinish closestmatchtofinishofframeand panels[ORstainlesssteelhinges]. Provide stainlesssteelsecurityhingepinswithsetscrews.
4.Adjustment: Providefolding/slidinghardwarecapableofspecifiedamountofcompensationandadjustments withoutneedingtoremovepanelsfromtracks,in width,1⁄16”(1.5mm)perhingeandinheight,1⁄16”(2mm)up anddown.
E. OtherComponents:
1.Weatherstripping: Providemanufacturer’sstandarddoublelayerEPDM,Q-lon gasketorbrushseals with atwo layerfiberglassreinforcedpolyamidefinat boththeinnerandouteredgeof doorpanelsor onframeforsealing betweenpanelsandbetweenpanelandframe. Singlelayerweatherstrippingwillnotbeallowed.
2.Providetaperedpinsorstainlesssteelscrewsforconnectingframecomponents.
2.03FABRICATION
A. Useextrudedaluminumframeandpanelprofiles,cornerconnectorsandhinges,slidingandfoldinghardware,locking hardwareandhandles,glassandglazingandweatherstrippingasspecifiedhereinto makea foldingglasswall. Factorypre-assembleasisstandardformanufacturerandshipwithall componentsandinstallationinstructions.
B. SizesandConfigurations:Seedrawingsfor selectedcustomdimensionswithinmaximumframesizespossibleas indicatedin manufacturer’sliterature. Seedrawingsfor selectednumberof panelsandconfiguration. Inward[OR outward]openingunit. Onconfigurationswitha pairofswingpanels,lookingfrominside,primaryswingpanelon theleft[ORright]
2.04ACCESSORIES(EDITFORPROJECTREQUIREMENTS.)
A. ProvidetheNanaScreen™,aseriesofvertical,collapsible,pleatedscreenpanels.Providepleatedscreenmaterialwith
floortrackingchainwith1/4"(6mm)floortrack. Seedrawingsforselectednumberofpanelsandconfiguration.
Providealuminumtoptrack,sidejambs,andverticalstruts: Whitepowdercoated
[ORclearanodized]
[ORdarkbronzeanodized]
[ORpowdercoatedselectfromrangeofRALpowdercoatedfinishesavailablefrommanufacturer]. NanaScreen™installationwithinopening[ORextendedbeyondopening]
B. Provideothersidelites,transoms,cornerposts,orsingleordoubledoorsasperdrawingsprovided. PART3-EXECUTION
3.01 ERECTION
A. Becauseofthelargedimensionsinvolvedandtheweightandmovementofthepanels,verifythestructuralintegrityof theheadersuchthatthedeflectionwithliveanddeadloadsislimitedtothelesserofL/720ofthespanand¼”(6mm). Structuralsupportforlateralloads(bothwindloadandeccentricloadwhenthepanelsarestackedopen)mustbeprovided.
ItisrecommendedthatallbuildingdeadloadsbeappliedtotheheaderpriortoinstallingtheNanaWall. Ifsoand if a reasonableamountoftimehasbeenallowedfor theeffectofthisdeadloadon theheader,thenonlythebuild- ing'sliveloadcanbeusedtomeettheaboverequirementsofL/720or¼”(6mm). Ifnot,boththedeadandlive loadsneedtobeconsidered
B. Examinesurfacesof openingsandverifydimensions;verifyroughopeningsare level,plumb,andsquare,withno unevenness,bowing,orbumpsonthefloor.
C. Installationofunitsconstitutesacceptanceofexistingconditions.
3.02 INSTALLATION
A. Installframeinaccordancemanufacturer’s recommendations andinstallationinstructions. Properlyflashand waterproofaroundtheperimeteroftheopening.
B. Installertoprovideappropriateanchoragedevicesandtosecurelyandrigidlyfitframeinplace,absolutelylevel, straight,plumbandsquare. Installframeinproperelevation,planeandlocation,andinproperalignmentwith otherwork.
C. Ifnecessary,providedrainconnectionsfromlowertrack.
D.Installpanels,handlesandlocksetin accordancewithmanufacturer’srecommendations andinstallation instructions.
E. Ifnecessary,adjusthardwareforproperoperation.
F. Accessories: Screens;installin accordancewithscreenmanufacturer’srecommendations andinstallation instructions.
ENDOFSECTION
DISCLAIMER: NanaWallSystems,Inc.takesnoresponsibilityforproductselectionorapplication,including,butnotlimitedto, compliancewithbuildingcodes,safetycodes,laws,orfitnessforaparticularpurpose. Theguidespecificationsisnotintended tobeverbatimasaprojectspecificationwithoutappropriatemodificationsforthespecificuseintendedandtheparticularrequire- mentsofaspecificconstructionproject.