NanaWall® SL70- Monumental,ThermallyBrokenAluminumFramedFolding

PanelSystem

PART1-GENERAL

1.01 SUMMARY

A. SectionIncludes:Sliding/foldingaluminumandglassdoorsystem,includingaluminumframe,threshold,panels,sliding/ foldingandlockinghardware,weatherstripping,glassandglazing;designedtoprovideanopeningglasswall,withsizesand configurationsas shownon drawingsandspecifiedherein,NanaWall® SL70,MonumentalThermallyBrokenAluminumFramed Folding PanelSystemassuppliedbyNanaWallSystems,Inc.

1.02 REFERENCES

A. AmericanArchitecturalManufacturersAssociation(AAMA):

1.AAMA520,VoluntarySpecificationforRatingtheSevereWind-DrivenRainResistanceofWindows, DoorsandUnitSkylights

2.AAMA611,VoluntarySpecificationforAnodizedArchitecturalAluminum.

3.AAMA1304,VoluntarySpecificationsforForcedEntryResistanceofSide-HingedDoorSystems.

4.AAMA2604,VoluntarySpecifications,PerformanceRequirementsandTestProceduresforHighPerformance

OrganicCoatingsonAluminumExtrusionsandPanels.

5.AAMA2605,VoluntarySpecifications,PerformanceRequirementsandTestProcedures forSuperiorPerforming

OrganicCoatingsonAluminumExtrusionsandPanels. B. AmericanSocietyforTestingandMaterials(ASTM):

1.ASTME283,TestMethodforRateofAirLeakagethroughExteriorWindows,CurtainWalls,andDoorsby

UniformStaticAirPressureDifference.

2.ASTM E330,TestMethodforStructuralPerformanceofExterior Windows,CurtainWalls, andDoors byUniform

StaticAirPressureDifference.

3. ASTME331,StandardTestMethodforWaterPenetrationofExteriorWindows,Skylights,Doors,andCurtain

WallsbyUniformStaticAirPressureDifference.

4.ASTME547,TestMethodforWaterPenetrationof ExteriorWindows,CurtainWalls,and DoorsbyCyclicStatic

AirPressureDifferential.

5.ASTME2268, StandardTest MethodforWaterPenetrationofExteriorWindows,Skylights,andDoorsbyRapid

PulsedAirPressureDifference

6.ASTMF 842,StandardTestMethodsforMeasuringtheForcedEntryResistanceofSlidingDoorAssemblies. C. AmericanNationalStandardsInstitute(ANSI):

1.ANSIZ97.1,SafetyPerformanceSpecificationsandMethodsofTestforSafetyGlazingMaterialUsedInBuild- ings.

D. ConsumerProductSafetyCommission(CPSC):

1.CPSC16CFR-1201,SafetyStandardforArchitecturalGlazingMaterials. E. NationalFenestrationRatingCouncil(NFRC):

1.NFRC100,ProcedureforDeterminingFenestrationProductThermalMaterials.

2.NFRC200,ProcedureforDeterminingSolarHeatGainCoefficient.

3.NFRC400,ProcedureforDeterminingFenestrationProductAirLeakage.

1.03 SUBMITTALS

A. DetailDrawings: Indicatedimensioning,directionofswing,configuration,swingpanels,typicalheadjamb,side jambsandsilldetails,typeofglazingmaterialandhandleheight.

B. ProductData:Manufacturer’s literatureincludingindependentlytesteddatalistingperformancecriteriaandOwner’s

Manualwithinstallationinstructions.

C. ContractCloseoutSubmittal: SubmitOwner’sManualfrommanufacturer. Identifywithprojectname,locationand completiondate,typeandsizeofunitinstalled.

1.04QUALITYASSURANCE

A. Manufacturer: Provide complete,precisionbuilt,engineered,pre-fittedunitbyasinglesourcemanufacturerwithat least25yearsexperience inprovidingfolding/slidingdoorsystemsforlargeopeningsintheNorthAmericanmarket.

1. ThemanufacturermusthaveaqualitymanagementsystemregistrationtotheISO9001:2008standard.

B. PerformanceCriteria:Providefrommanufacturerthathasindependentlytestedtypicalunitswiththefollowing minimumresults.

1.Airinfiltration: Providesystemwithmaximumairleakageof0.30cfm/sqftwhentestedaccordingtoASTME

283andNFRC400atastaticairpressuredifferenceof1.57psfand 6.24psf.

2.WaterPenetrationunderStaticPressure:

a. Providesystemwitharaisedsill(inswingoroutswing)thatdonotevidencewaterpenetrationwhen testedaccordingtoASTME 331andASTME547atastaticairpressuredifferenceof12psf.

b. Providesystemwithasaddlesillwithtypicalfieldinstalledweepholesanddrainagebyothers(see drainageinstructionsfromNanaWall)thatdo notevidencewaterpenetrationwhentestedaccordingto ASTM E331andASTME547atastaticairpressuredifferenceof5.25psfforaninswingunitand6.00psfforan outswingunit.

3.WaterPenetrationunderDynamicPressure:Providesystemwitharaisedsillthatdonotevidencemorethan allowablewaterentrywhentestedaccordingtoAAMA520andASTME 2268ata dynamicratedairpressure differenceof 6-18psffor an inswingunit(PerformanceLevel2) and5-15psffor an outswingunit(Performance Level1).

4.StructuralTestPerformance:

a.ProvidesystemwithoptionalreinforcedpoststhatwhentestedaccordingtoASTME330at150%ofpositive andnegativedesignpressureswithpanelsizesof3’wideand8’highachievedwithaninswingunitwitha raisedsill DPratingof +70psf/-100psfandan outswingunitwitharaisedsill andinswing/outswingunitswith saddlesillsDPratingsof+/-70psf.

b. ProvidestandardsystemthatwhentestedaccordingtoASTME330at150%ofpositiveandnegative designpressureswithpanel sizesof2’11”wide and8’1”highachievedwithaninswingunitwitharaisedsillDP ratingof+55 psf /-90 psf, anoutswingunit witharaisedsillDP ratingof-90 psf /+55psf andinswing/outswing unitswithsaddlesillsDPratingsof+/-50psf.

5.ForcedEntryResistance: ProvidesystemthatwhentestedaccordingtoASTMF842andAAMA1304there wasnoentry.

SPECIFIERNOTE:Airinfiltrationandwaterpenetrationtestingresultscanonlybeapplicableiftheunit matchesthetestunitinthedirectionofopeningandthetypeofsill.Structuralloadtestingresultsareonly applicableforthetestunitsize.(Comparativeanalysischartsforunits publishedbymanufacturershowwhich panelsizes(ifany)wouldmeetthestructuralloadingdesignpressuresspecificallyrequiredfortheproject. Checkforlimitationsontheuseofthesechartsinthejurisdictionoftheproject).Seemanufacturer’slatest publisheddata.]

C. ThermalPerformanceUfactor:Unittoberated,certifiedandlabeledinaccordancewithNFRC100,shownin manufacturer’slatestpublisheddatafortheglazing,sill,anddirectionofopeningspecified.

D. SolarHeatGainCoefficient:Unittoberated,certifiedandlabeledinaccordancewithNFRC200,showninmanufac- turer’slatestpublisheddatafortheglazing,sill,anddirectionofopeningspecified.

SPECIFIERNOTE: Ifdesired,EnergyStarratingscanbeachievedbytheuseofproperglasswiththeunit. SeeNanaWall’sPerformancedatafordetails.

E. InstallerQualifications: Installerexperiencedin theinstallationof manufacturer’sproductor othersimilarproducts forlargeopenings.Installertoprovidereferencelistofatleast3 projectsof similarscaleand complexitysuccess- fullycompletedinthelast3years.

1.05WARRANTY

A. Providemanufacturer’sstandardwarrantyagainstdefectsinmaterialsandworkmanship.

B. WarrantyPeriod:Tenyearsforrollers.Forallothercomponents,oneyear(twoyearsifunitisinstalledbymanufac- turer’scertifiedtrainedinstaller)fromdateofdeliverybymanufacturer.

PART2–PRODUCTS

2.01SUPPLIER

A. NANAWALLSYSTEMS,INC.

100 Meadow Creek Drive, Corte Madera, CA 94925

TollFree:(800)873-5673

Telephone:(415)383-3148

Fax:(415)383-0312

Website:

Email:

2.02MATERIALS

A. FrameandPanels:From manufacturer’sstandardprofiles,provideheadtrack, sidejambs,andpanelswithdimen- sionsshownondrawings.

1.Providepanelswith: Standardonelite

[ORwithhorizontalmullion(s)atspecifiedheight(s)fromthebottomofthepanel] [ORwithsimulateddividedlitesinpatternasshownondrawings]

2.Providestandardbottomrail[ORmanufacturer’sstandardkickplatewithheightspecified].

3.AluminumExtrusion: Extrusionswithnominalthicknessof.078”(2.0mm). AlloyspecifiedasAIMgSi0.5with strengthratedas6063-T5orF-22(Europeanstandard).AnodizedconformingtoAAMA611,powdercoated conformingtoAAMA2604orfluoropolymarkynarpaintedconformingtoAAMA2605.

4.Thermallybrokenwith¾”-15⁄16”(20-24mm)polyamideplasticreinforcedwithglassfibers.Polyamideplastic lessthan3/4"(20mm)wideorpourandde-bridgethermalbreakwillnotbeaccepted.

5.AluminumFinish:

SelectfromNanaWallPowderCoatingFinishChart

[ORclearanodized]

[ORdarkbronzeanodized]

[ORselectfromrangeofRALhighglosspowdercoatedfinishesavailablefrommanufacturer] [ORselectfromrangeofRALmattepowdercoatedfinishesavailablefrommanufacturer]

[ORWoodGrainpowdercoatedfinish]

[ORselectfromrangeofflouropolymarkynarpaintedfinish] [ORcustomfinish].

Same[ORdifferent]finishesoninsideandoutside. B. Glass:

1.AllglasstocomplywithsafetyglazingrequirementsofANSIZ97.1andCPSC16CFR1201.Providemanufac- turer’sstandardglasswithdryglazingwithglassstopsontheinsideonly:

15/16”(24mm)doubleinsulatedclearsafety

[OR15/16”(24mm)doubleinsulatedargonfilledLow-Esafety]

[OR11/2”(38mm)doubleinsulatingkryptonfilledtwolayersHeatMirrorTC88safety] [OR11/2”(38mm)tripleinsulatedargonfilledLowEsafety]

[OR11/8"(28mm)OrniluxBirdSafeGlass]

[ORotherglassavailablefrommanufacturer,includingglasswithothertotalthickness].

2.Providemanufacturer’sstandardsilvergray[ordark bronze]glassspacers. Providewithoutcapillarytubes[OR

withcapillarytubes].

C. LockingHardwareandHandles:

1.Mainentrypanel:

Onthemainentrypanelformodelswithapairofswingpanels,providemanufacturer’sstandardleverhandles ontheinsideandoutside,aSchlagecompatiblelocksetwithlockablelatch,multi-pointlockingwithadead bolt androdsatthetopandbottomonprimarypanel. Rodstobeconcealedandnotedgemounted. After

turnofkeyorthumburn,depressionofhandleswithdrawslatch. Liftingofhandlesengagesrodsandturnof keyorthumbturnengagesdeadboltandoperateslock. Onthesecondaryswingpanel,providematching dummyleverhandlesonbothsidesandconcealedflushboltsthatoperatestherodsatthetopandthebottom forthesecondaryswingpanel.

Stainlesssteelleverhandlesinatitaniumblackfinish

[ORstainlesssteelleverhandlesinabrushedsatinfinish] [ORoil rubbedbronzesolidbrassleverhandles]

[ORsatinnickelsolidbrassleverhandles] [ORwhitesolidbrassleverhandles]

[ORonthemainentrypanelformodelswithaswingpanel,providemanufacturer’sstandardleverhandleson theinsideandoutside,aSchlagecompatiblelocksetwithlockablelatch,multi-pointlockingwithadeadbolt and rodsatthetopand bottomonprimarypanel only. Rodstobeconcealedand notedge mounted. Afterturn of key or thumbturn,depressionof handleswithdrawslatch. Liftingof handlesengagesrodsandturnof keyor thumbturnengagesdeadboltandoperateslock.Ifthereisasecondaryswingpanel,providetwo pointlocking withUshapedhandlesoninsideonlyforthesecondaryswingpanel.]

Stainlesssteelleverhandlesinatitaniumblackfinish

[ORstainlesssteelleverhandlesinabrushedsatinfinish] [ORoil rubbedbronzesolidbrassleverhandles]

[ORsatinnickelsolidbrassleverhandles] [ORwhitesolidbrassleverhandles]

[ORonthemainentrypanelformodelswithaswingpanel,providemanufacturer’s push/pullhandleswithseparate locksetanddeadboltandonepointlockingatthetopandbottomconsistingoflockingrodsoperatedbya 180º turnofaflathandlesontheinside]

Push-pullhandlesinabrownnylonfinishandstainlesssteelflathandlesinatitaniumblack

finish

[ORpush-pullhandlesinagray nylonfinishandstainlesssteelflathandlesinabrushedsatin

finish]

[ORpush-pullhandlesina whitenylonfinishandstainlesssteelflathandlesina brushedsatin

finish]

SPECIFIER’SNOTE:This optionisrecommendedwith adoorcloser,butnotethat inordertoslidetheswing panel,thedoorcloserwillneedtobedisengagediftheswingpanelisnotattachedtoasidejamb.]

[ORonthemainentrypanelformodelswithaswingpanel,nohardwareorlockingtobeprovided bythemanufacturer,butwithfieldinstalledpanicdevicebyothers.]

[ORonbothentrypanelsformodelswithapairofswingpanels,nohardwareorlockingto

beprovidedbythemanufacturer,butwithfieldinstalledpanicdevicesonbothpanelsbyothers.] SPECIFIER’SNOTE: Structuraltestloadresultswillnotapplyforlockingdevicesbyothers.

[ORonmainentrypairofpanelsonmodelswithoutaswingpanel,providemanufacturer’sstandard

L-shapedhandlesontheinsideandontheoutsideandlockset withprofilecylinder. Operationof lock setisbyturnofkeyfromtheoutsideandwithathumbturnfromtheinsidewithatwopointlocking hardwareoperatedby180ºturnofthehandle.]

StainlesssteelLshapedhandlesinatitaniumblackfinish

[ORstainlesssteelLshapedhandlesinabrushedsatinfinish] [ORLshapedhandlesinabrownnylonfinish]

[ORLshapedhandlesinagraynylonfinish] [ORLshapedhandlesinawhitenylonfinish

[ORon mainentrypanel,providemanufacturer’sstandardU/L shapedhandleon insideonlywith concealedtwopointlockinghardwareoperatedby180degreeturnofhandle.

SPECIFIER’SNOTE: Notethatwiththisoption,themainentrypanelisoperablefrominsideonlyandthat thereisnolatch.]

SPECIFIER’SNOTE: Notethatothercompatiblelever,Lshapedandpush-pullhandlestylesandfinishes areavailablefromothersuppliers.

2.On allothersecondarypanelsand pairsoffoldingpanels,providemanufacturer’sstandardhandles[ORremov- ablecustodialhandles]andconcealedtwopointlockinghardwareoperatedby180degreeturnofhandlebetween eachpair. Faceappliedflushboltlockingwillnotbeallowed. Standardhandlefinish:

Stainlesssteelstandardhandlesinatitaniumblackfinish

[ORStainlesssteelstandardhandlesinabrushedsatinfinish] [ORstandardhandlesinabrownnylonfinish]

[ORstandardhandlesinagraynylonfinish] [ORstandardhandlesinawhitenylonfinish]

3.Providehandleheightcenteredat41⅜”[ORasspecified]frombottomofpanel.

4.Aluminumlockingrodswithstandardfiberglass reinforcedpolyamideendcapsattopandbottom.Rods tohave astrokeof15⁄16”(24mm).

5.Iftherearemorethanoneunit,keyedalike[ORkeyeddifferently].

D.Sliding/FoldingHardware:Providemanufacturer’sstandardcombinationslidingand foldinghardwarewith top, bottomtracksandthreshold. Allrunningcarriagestobewithsealed,self-lubrication,ballbearingmulti-rollers. Surfacemountedhingesandrunningcarriageswill notbeallowed. Weightof panelsto bebornebythe bottomof theguidechannelin thesillwillnotbeallowed.

1.Provideupperguidecarriageandlowerrunningcarriagewithfourverticalstainlesssteelwheelsandtwohorizon-

talpolyamidewheels.Theverticalwheelstorideontopofstainlesssteelguidetrackcoversoverthefulllength of thesilltrackandlie abovethewaterrun-offlevel. Carryingcapacityof lowerrunningcarriageto be440lbs (200kgs). Wheelsridingbelowthewaterrun-offleveland/orwheelsridingonaluminumsurfaceswill notbeallowed.

2.Threshold:

Providethermallybrokenwithpolyamideraisedsillinthesamefinishaspanelfinish

[ORclearanodizedlowprofilesaddlesill]

[ORdarkbronzeanodizedlowprofilesaddlesill] [ORclearanodizedflushsill]

[ORdarkbronzeanodizedflushsill]

[ORclearanodizedSurfaceMountedInteriorSill] [ORbronzeanodizedSurfaceMountedInteriorSill]

A coverplateoverthesillwillnotbeallowed.

3.Hinges:Zincdie castwithfinish closestmatchtofinishofframeand panels[ORstainlesssteelhinges]. Provide stainlesssteelsecurityhingepinswithsetscrews.

4.Adjustment: Providefolding/slidinghardwarecapableofspecifiedamountofcompensationandadjustments withoutneedingtoremovepanelsfromtracks,in width,1⁄16”(1.5mm)perhingeandinheight,1⁄16”(2mm)up anddown.

E. OtherComponents:

1.Weatherstripping: Providemanufacturer’sstandarddoublelayerEPDM,Q-lon gasketorbrushseals with atwo layerfiberglassreinforcedpolyamidefinat boththeinnerandouteredgeof doorpanelsor onframeforsealing betweenpanelsandbetweenpanelandframe. Singlelayerweatherstrippingwillnotbeallowed.

2.Providetaperedpinsorstainlesssteelscrewsforconnectingframecomponents.

2.03FABRICATION

A. Useextrudedaluminumframeandpanelprofiles,cornerconnectorsandhinges,slidingandfoldinghardware,locking hardwareandhandles,glassandglazingandweatherstrippingasspecifiedhereinto makea foldingglasswall. Factorypre-assembleasisstandardformanufacturerandshipwithall componentsandinstallationinstructions.

B. SizesandConfigurations:Seedrawingsfor selectedcustomdimensionswithinmaximumframesizespossibleas indicatedin manufacturer’sliterature. Seedrawingsfor selectednumberof panelsandconfiguration. Inward[OR outward]openingunit. Onconfigurationswitha pairofswingpanels,lookingfrominside,primaryswingpanelon theleft[ORright]

2.04ACCESSORIES(EDITFORPROJECTREQUIREMENTS.)

A. ProvidetheNanaScreen™,aseriesofvertical,collapsible,pleatedscreenpanels.Providepleatedscreenmaterialwith

floortrackingchainwith1/4"(6mm)floortrack. Seedrawingsforselectednumberofpanelsandconfiguration.

Providealuminumtoptrack,sidejambs,andverticalstruts: Whitepowdercoated

[ORclearanodized]

[ORdarkbronzeanodized]

[ORpowdercoatedselectfromrangeofRALpowdercoatedfinishesavailablefrommanufacturer]. NanaScreen™installationwithinopening[ORextendedbeyondopening]

B. Provideothersidelites,transoms,cornerposts,orsingleordoubledoorsasperdrawingsprovided. PART3-EXECUTION

3.01 ERECTION

A. Becauseofthelargedimensionsinvolvedandtheweightandmovementofthepanels,verifythestructuralintegrityof theheadersuchthatthedeflectionwithliveanddeadloadsislimitedtothelesserofL/720ofthespanand¼”(6mm). Structuralsupportforlateralloads(bothwindloadandeccentricloadwhenthepanelsarestackedopen)mustbeprovided.

ItisrecommendedthatallbuildingdeadloadsbeappliedtotheheaderpriortoinstallingtheNanaWall. Ifsoand if a reasonableamountoftimehasbeenallowedfor theeffectofthisdeadloadon theheader,thenonlythebuild- ing'sliveloadcanbeusedtomeettheaboverequirementsofL/720or¼”(6mm). Ifnot,boththedeadandlive loadsneedtobeconsidered

B. Examinesurfacesof openingsandverifydimensions;verifyroughopeningsare level,plumb,andsquare,withno unevenness,bowing,orbumpsonthefloor.

C. Installationofunitsconstitutesacceptanceofexistingconditions.

3.02 INSTALLATION

A. Installframeinaccordancemanufacturer’s recommendations andinstallationinstructions. Properlyflashand waterproofaroundtheperimeteroftheopening.

B. Installertoprovideappropriateanchoragedevicesandtosecurelyandrigidlyfitframeinplace,absolutelylevel, straight,plumbandsquare. Installframeinproperelevation,planeandlocation,andinproperalignmentwith otherwork.

C. Ifnecessary,providedrainconnectionsfromlowertrack.

D.Installpanels,handlesandlocksetin accordancewithmanufacturer’srecommendations andinstallation instructions.

E. Ifnecessary,adjusthardwareforproperoperation.

F. Accessories: Screens;installin accordancewithscreenmanufacturer’srecommendations andinstallation instructions.

ENDOFSECTION

DISCLAIMER: NanaWallSystems,Inc.takesnoresponsibilityforproductselectionorapplication,including,butnotlimitedto, compliancewithbuildingcodes,safetycodes,laws,orfitnessforaparticularpurpose. Theguidespecificationsisnotintended tobeverbatimasaprojectspecificationwithoutappropriatemodificationsforthespecificuseintendedandtheparticularrequire- mentsofaspecificconstructionproject.