Certificate of Analysis

Parsons Brinkerhoff Australia Pty Limited

Level 27, Ernst Young Centre

680 George Street GPO Box 5394 Sydney NSW 2001

Australia

Telephone +61 2 9272 5100

Facsimile +61 2 9272 5101

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 900 1

CLIENT: UGL Process Solutions Ply ltd

CLIENT ADDRESS: 64 Northbourne Avenue, Canberra ACT 2601

TELEPHONE: 02 6245 6874

FAX I E-MAIL:


CERTIFICATE NO: 21607528-0174

DATE SAMPLED. 6/01/2011

DATE RECEIVED: 6/01/2011

DATE ANALYSED: 6/01/2011

CONTACT:

LOCATION:

SAMPLED BY:

Rene Polski

Anzac Rifle Range. Franklin Street. Malabar NSW 2036

Kate Warton

Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres. Parsons Brinckerhoff's Laboratory Quality Procedure LQP1 Counting of Asbestos Fibre (In-house Method 1) and NATA Accreditation No: 17199

Background Air Monitoring Results

Lab

Number

M001 Riding School Store, Building SA, Unit 8

M002 Riding School Store, Building 5, Unit 7

M003 Riding School Office

M004 Caretakers house, on eastern fence

M005 Southern boundary temporary fence

NB: If the fibre count is less than ·to fibres per 100 fields then the count is not significantly above that of background Guidance note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC:3003 (2005)]

ACCREDITED FOR TECHNICAL COMPETENCE


Result Concentration

Fibres/Field) (Fibres/mL)

0/100 0.01

0/100 0.01

0.5/100 0.01

0/100 <0.01

0/100 0.01

Approved Counter

Name: Ryan Straub

Signature

ORIGINAL SIGNED

Approved Signatory

Name: Ryan Straub Signature

This document is issued in accordance with NATA's accreditation requirements. Accredited for compliance with ISO/IEC 17025. The results contained within this report relate only to the sample(s) submitted for testing. PB accepts no responsibility for the initial collection, packaging or transportation of samples submitted by external persons. NATA does not accredit sampling This document may not be reproduced except in full.

Over a Century of Engineering Excellence

ORIGINAL SIGNED

AUTHORISATION DATE

6/01/2011

Page I of 1

Certificate of Analysis

Parsons Brinkerhoff Australia Pty Limited

Level 27 Ernst & Young Centre

680 George Street

GPO Box 5394

Sydney NSW 2001

Australia

Telephone +61 2 9272 51 00

Facsimile +61 2 9272 510'1

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 9001

CLIENT: UGL Process Solutions Pt y Ltd

CLIENT ADDRESS· 64 Northbourne Avenue, Canberra ACT 2601

TELEPHONE: 02 6245 6874

FAX I E-MAIL; lrene.Polski@uglimited com


CERTIFICATE NO: 21607528-0156

DATE SAMPLED: 5/01/2011

DATE RECEIVED 5/01/2011

DATE ANALYSED· 6/01/2011

CONTACT:

LOCATION:

Rene Polski

Anzac Rifle Range, Franklin Street , Malabar NSW 2036

SAMPLED BY: Kate Warton

TEST METHOD Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres, Parsons Brinckerhoff's Laboratory Quality Procedure LQP1 Counting of Asbestos Fibre (In-house Method 1) and NATA Accreditation No: 17199

Background Air Monitoring Results

Lab

Number

M001

M002

M003

M004

M005

Riding School Office

Riding School Store, Building 5, Unit 7

Riding School Store, Building SA, Unit 8

Caretakers house, on eastern fence

Southern boundary temporary fence around barracks huts


Result

(Fibres/Field)

0/100

1/100

0/100

0/100

1/100


Concentration

(Fibres/mL)

0.01

<0.01

<001

0.01

0.01

NB: If the fibre count is less than 10 fibres per 100 fields then the count is not significantly above that of background. Guidance note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC:3003 (2005)]

.ACCREDITED FOR TECHNICAL COMPETENCE

Approved Counter

Name: Kate Warton

Signature

ORIGINAL SIGNED

Approved Signatory

Name: Kate Warton

Signature

This document is issued in accordance with NATA's accreditation requirements.

Accredited for compliance with ISO/IEC 1 702S. The results contained within this report relate only to the sample(s) submitted for testing. PB accepts no responsibility for the initial collection, packaging or transportation of samples submitted by external persons. NATA does not accredit sampling. This document may not be reproduced except in full

Over a Century of Engineering Excellence


ORIGINAL SIGNED

AUTHORISATION DATE

6/01/2011

Page 1 of 1

Certificate of Analysis


Parsons Brinckerhoff Australia Pty Limited


Level 27 Ernst & Young Centre

680 George Street

GPO Box 5394

Sydney NSW 2001

Australia

Telephone +61 2 9272 51 00

Facsimile +61 2 9272 510'1

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 9001

CLIENT: UGL Process Solutions Pty Ltd

CLIENT ADDRESS: 64 Northbourne Avenue. Canberra ACT 2601 TELEPHONE: 02 6245 6874

FAX/EMAIL:


DATE SAMPLED:. 4/01/2011

DATE RECEIVED: 4/01/2011

DATE ANALYSED 5/01/2011

CONTACT: LOCATION:

SAMPLED BY:

Rene Polski

ANZAC Rifle Range. Franklin Street. Malabar NSW 2036 Kate Warton

Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres. Parsons Brinckerhoff's laboratory Quality Procedure LQP1 Counting of Asbestos Fibre (In-house Method 1) and NAT A Accreditation No: 17199

Background Air Monitoring Results

Lab

Number

M001

M002

M003

M004

M005

M006


Location

SSAA toilets (Mens)

Riding School Toilets (ladies)

Riding School Storerooms (Building SA). Unit 8

Riding School Storerooms (Building 5), Unit 8

Riding School Office

Southern boundary temporary fence around barracks huts


Result

(Fibres/Field)

0 / 100

2 I 100

0 I 100

0 I 100

0 I 100

0 I 100


Concentration

(Fibres/mL)

0.01

0.01

<0.01

0.01

<0.01

0.01

NB: If the fibre count is less than 10 fibres per 100 fields then the count is not significantly above that of background. Guidance note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC:3003 (2005)]

ACCREDITED FOR TECHNICAL COMPETENCE

This document is issued in accordance with NATA's accreditation requirements. Accredited for compliance with ISO/IEC 17025. The results contained within this report relate only to the sample(s) submitted for testing. PB accepts no responsibility for the initial collection, packaging or transportation of samples submitted by external persons.

Approved Counter

Name: Kate Warton

Signature

ORIGINAL SIGNED

Approved Signatory Name: Kate Warton Signature

ORIGINAL SIGNED

AUTHORISATION DATE

5/01/2011

Certificate of Analysis

Parsons Brinkerhoff Australia Pty Limited

Level 27. Ernst Young Centre

680 George Street

GPO Box 5394

Sydney NS W 200·1

Australia

Telephone +61 2 9272 5100

Facsimile +61 2 9272 5101

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 9001

CLIENT: UGL Process Solutions Pty ltd

CLIENT ADDRESS: 64 Northbourne Avenue, Canberra ACT 2601

TELEPHONE: 02 6245 6874

FAX/EMAIL: lrene.Polski@ugllimited. com


CERTIFICATE NO: 21607528-0150

DATE SAMPLED: 3111212010

DATE RECEIVED: 3111212010

DATE ANALYSED 3111212010

CONTACT:

LOCATION:

SAMPLED BY: TEST METHOD:

Rene Polski

Anzac Rifle Range, Franklin Street, Malabar NSW 2036

Shane Waterson

Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres, Parsons Brinckerhoff's Laboratory Quality Procedure LQP1 Counting of Asbestos Fibre (In-house Method 1) and NATA Accreditation No: 17199

Background Air Monitoring Results

Lab

Number

M001

M002

M003

M004

M005

M006

Riding School Office

Riding School Storage (Building 5) within Unit A1

Riding School Storage (Building SA), within Unit 2

Riding School Toilets (Ladies Toilets) SSAA Toilets (Mens Toilets)

Southern boundary temporary fence around Barracks Huts


Result

(Fibres/Field)

0I100

1.51100

0/100

1/100

0I100

31100


Concentration (Fibres/mL)

0.01

0.01

<0.01

<0.01

0.01

<0.01

NB: If the fibre count is less than 10 fibres per 100 fields then the count is not significantly above that of background. Guidance note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC:3003 (2005)]

ACCREDITED FOR TECHNICAL COMPETENCE

This document is issued in accordance with NATA's accreditation requirements. Accredited for compliance with ISO/IEC 17025. The results contained within this report relate only to the sample(s) submitted for testing. PB accepts no responsibility for the initial collection, packaging or transportation of samples submitted by external persons. NAT!\ does not accredit sampling. This document may not be reproduced except in full.

Over a Century of Engineering Excellence

Approved Counter

Name: Shane Waterson

Signature

ORIGINAL SIGNED

Approved Signatory

Name: Shane Waterson

Signature

ORIGINAL SIGNED

AUTHORISATION DATE

31/12/2010

Page 1 of 1

Certificate of Analysis

Parsons Brinkerhoff Australia Pty Limited

Level 27. Ernst Young Centre

680 George Street

GPO Box 5394

Sydney NS W 200·1

Australia

Telephone +61 2 9272 5100

Facsimile +61 2 9272 5101

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 9001

CLIENT: UGL Process Solutions Pty Ltd

CLIENT ADDRESS: 64 Northbourne Avenue, Canberra ACT 2601

TELEPHONE: 02 6245 6874

FAX I E-MAIL:

CERTIFICATE NO: 21607528-0149

DATE SAMPLED: 30/12/2010

DATE RECEIVED: 30/12/2010

DATE ANALYSED: 30/12/2010

CONTACT:

LOCATION:

SAMPLED BY:

TEST METHOD:

Rene Polski

Anzac Rifle Range, Franklin Street. Malabar NSW 2036

Shane Waterson

Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres, Parsons Brinckerhoff s Laboratory Quality Procedure LQP1 Counting of Asbestos Fibre (In-house Method 1) and NATA Accreditation No: 17199

Background Air Monitoring Results

Lab Number

M001

M002

M003

M004

M005

M006

Riding School Office

Riding School Storage (Building 5), within Unit A1

Riding School Storage (Building 5A), within Unit 2

Riding School Toilets (ladies Toilets} SSAA Toilets (Mens Toilets)

Southern boundary temporary fence around Barracks Huts


Result

(Fibres/Field)

3.5/100

1/00

0/100

1.5/100

2/100

0.5/100


Concentration (Fibres/mL)

<0.01

0.01

0.01

0.01

0.01

0.01

NB: If the fibre count is less than 10 fibres per 100 fields then the count is not significantly above that of background. Guidance note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC :3003 (2005)]

Approved Counter

Name: Shane Waterson

- ORIGINAL SIGNED

ACCREDITED FOR TECHNICAL COMPETENCE

This document is issued in accordance with NATA's accreditation requirements. Accredited for compliance with ISO/IEC 17025. The results contained within this report relate only to the sample(s) submitted for testing. PB accepts no responsibility for the initial collection, packaging or transportation of samples submitted by external persons.

Approved Signatory

Name: Shane Waterson

Signature

ORIGINAL SIGNED

AUTHORISATION DATE

30/12/2010

Certificate of Analysis

Parsons Brinkerhoff Australia Pty Limited

Level 27 . Ernst & Young Centre

680 George Street

GPO Box 5394

Sydney NSW 2001

Australia

Telephone +61 2 9272 5100

Facsimile +61 2 9272 5 1 01

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 9001

CLIENT: UGL Process Solutions Ply Ltd

CLIENT ADDRESS: 64 Northbourne Avenue. Canberra ACT 2601

TELEPHONE: 02 6245 6874

FA X I E-MAIL:


CERTIFICATE NO: 21607528-0141

DATE SAMPLED: 29/12/2010

DATE RECEIVED: 29/12/2010

DATE ANALYSED: 29/12/2010

CONTACT LOCATION: SAMPLED BY TEST METHOD:

Rene Polski

Anzac Rifle Range, Franklin Street, Malabar NSW 2036

Shane Waterson

Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres , Parsons Brinckerhoff's Laboratory Quality Procedure LQP1 Counting of Asbestos Fibre (In-house Method 1) and NATA Accreditation No: 17199

Background Air Monitoring Results

M001

M002

M003

M004

M005

M006

Riding school office

Riding school storage (building 5), within Unit A1

Riding school storage (building 5A), within Unit 2

Riding school toilets (ladies toilet) SSAA toilets (mens toilets)

Southern boundary temporary fence around barracks huts


Result

(Fibres/Field)

0/100

0/100

0/100

1/100

0.5/100

0/100


Concentration

(Fibres/mL)

0.01

0.01

0.01

0.01

0.01

0.01

NB: If the fibre count is less than 10 fibres per 100 fields then tile count is not significantly above that of background. Guidance note on the Membrane filter Method for Estimating Airborne Asbestos Fibres [NOHSC:3003 (2005)]

ACCREDITED FOR TECHNICAL COMPETENCE

This document is issued in accordance with NAT A's accreditation requirements. Accredited for compliance with ISO/IEC 17025. The results contained within this report relate only the sample(s) submitted for testing. PB accepts no responsibility for the initial collection. packaging or transportation of samples submitted by external persons. NATA does not accredit sampling. This document may not be reproduced except in full.

Approved Counter

Name: Shane Waterson

Signature

ORIGINAL SIGNED

Approved Signatory

Name: Silane Waterson

Signature

ORIGINAL SIGNED

AUTHORISATION DATE

29/12/2010

Certificate of Analysis

Parsons Brinkerhoff Australia Pty Limited

Level 27, Ernst & Young Centre

680 George Street

GPO Box 5394

Sydney NSW 2001

Australia

Telephone + 61 2 272 5100

Facsimile +61 2 9272 5101

Email

ABN 80 078 004 798

NCSI Certified Quality System ISO 9001

CLIENT: UGL Process Solutions Ply Ltd

CLIENT ADDRESS: 64 Northbourne Avenue. Canberra ACT 2601

TELEPHONE: 02 6245 6874

FAX I E-MAIL:


CERTIFICATE NO: 21607528-0140

DATE SAMPLED: 24/12/2010

DATE RECEIVED: 24/12/2010

DATE ANALYSED: 24/12/2010

CONTACT:

LOCATION:

SAMPLED BY:

TEST METHOD

Rene Polski

Anzac Rifle Range, Franklin Street , Malabar NSW 2036

Warren La!

Filters examined at Parsons Brinckerhoff's Sydney Laboratory in accordance with N.O.H.S.C (April 2005) Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres, Parsons Brinckerhoff's Laboratory Quality Procedure LQP1 Counting of Asbestos Fibre {In-house Method 1) and NAT A Accreditation No: 17199

Background Air Monitoring Results

Lab

Number

M001

M002

M003

M004

M005

M006

Southern boundary of temporary fence around Barracks

Huts

SSAA Toilets {Male Toilets)

Riding School Toilets (Female Toilets)

Riding School Storage (Building 5A), within Unit 2

Riding School Storage (Building 5). within Unit A1

Riding School Office


Result

(Fibres/Field)

1/100

0/100

3/100

0/100

0/100

0/100


Concentration

(Fibres/mL)

0.01

0.01

<0.01

0.01

<0.01

<0.01

NB: If the fibre count is less than 10 fibres per 100 fields then the count is not significantly above that of background. Guidance note on the Membrane Filter

Approved Counter

Name: Warren Lal

Method for Estimating Airborne Asbestos Fibres

[NOHSC:3003 (2005)]

Signature

ORIGINAL SIGNED

ACCREDITED FOR TECHNICAL COMPETENCE