DETENTIONS IN PORT OF KOPER IN THE YEAR 2009

1
Date & Place of Detention / 2
Vessel Name, Type, IMO No & GT / 3

Flag

/ 4
Owners
Operator

Charterers

/ 5
Classification Society / 6
Summary
5/01/2009
Koper / ANDELIN
General cargo
7324649
3.527 / St Vincent & Grenadine / Alfamaine Shipping
Tartouson
Syria / International Naval Survey Bureau / Detained for 4 days.
21 recorded deficiencies.
Wheelhouse bulkhead corroded through. Two way VHF used for daily routine communications. ER air vent corroded through. ER top deck corroded through. Monkey deck corroded through. Radio room bulkhead corroded through. CO2 room bulkhead corroded through. Air condition room bulkhead corroded through. Alleyway bulkhead corroded through. On hold 1 hatch covers’ frames corroded through. On FCSL two ropes to be renewed. Ball protection on trim tank air pipe corroded through. On hold 2 hatch covers’ frames corroded through. Deck under boiler corroded through. AP tank bulkhead corroded through. Glands on pump for DGs cooling water leaks. ME fuel leaking alarm inoperative. Deck in washing room corroded through. Crew has no safety shoes. Lifeboat engine inoperative. ISM maintenance of ship and equipment failed.
09/01/2009
Koper / TOUAREG
General cargo
7528556
5.382 / Sierra Leone / Cata Shipping Co.
Tartous
Syria / Detained for 11 days.
Ship security plan not approved. Air conditions cables improperly installed through cabin bulkheads. Grated floor plates behind wheelhouse damaged. Monkey deck corroded through. Alleyway door on boat deck corroded through. Alleyway threshold on boat deck corroded through. Access to lifeboat ladder obstructed with empty drums. A/C doors on poop deck holed. On PS 4 hatch coaming frames corroded through. PS forepeak air pipe cracked. STB chain locker bulkhead corroded through. Paint room door corroded through. On FCSL air vent for store room corroded through. FWD hold PS 3 frames corroded through. FWD hold 4 frames corroded through. Bulkhead between hold and store corroded through. Doors on FWD bulkhead between hold and store room not water tight. One gusset plate between frames corroded through. Both FWD hold platforms damaged and corroded through. Bulkheads on wing tanks on both ship’s sides cracked and corroded through. On STB 1 frame cracked in two places. Main fire line in ER corroded through. Grey water line in ER corroded through. ISM – maintenance of ship and equipment failed.
15/01/2009
Koper / QUINGDAO REEFER
Reefer ship
8312033
7.777 / Liberia / Laskaridis Shipping
Piraeus
Greece / Nipon Kaiji Kyokai / Detained for 3 days.
33 recorded deficiencies. On both gangways sides supports corroded through. ME inoperative, camshaft air distributor damaged. Antifouling certificate missing. Radio room bulkhead corroded through. Crew mess room bulkhead corroded through. Officers’ mess room bulkhead corroded through. ER air vent corroded through. ME LO air pipe ball protection corroded through. Head of 4PBWT air pipe cracked. Entrance in COP2 room obstructed. CO2 room floor slippery. Head of 2PF air pipe cracked. Hold 1 entrance door corroded through. Air vent pipe on mast house corroded through. On STB hold 2 air vents corroded through. Both ball protections on 2S WBT air pipes corroded through. STB hold air vent AB4 corroded through. Cover on air vent 4CD corroded through. On STB front bridge bulkhead corroded through. Air vent on tally room corroded through. Step on main door entrance corroded through. Ball protection on sludge tank air pipe corroded through. In crew toilet all pisoars inoperative. In toilet grey water line temporary repaired. Starting handles on all DGs blocked with wires. Bilge under DGs dirty. Hot well connection pipe temporary repaired. In ER grey water line temporary repaired. Drain cocks on settling tank and service tank blocked. Base of cargo refrigerating pump corroded through. ME and DGs cooling water line temporary repaired. Abandon drill failed. ISM maintenance of ship and equipment failed.
22/01/2009
Koper / MED INTEGRITY
Bulk carrier
8307961
26.195 / Panama / Mediterranean Maritime
Piraeus
Greece / Bureau Veritas / Detained for 11 days.
32 recorded deficiencies.
Both ER air vents corroded through. Ball protection on emergency generator tank air pipe corroded through. Deck over pantry corroded through. Galley door square corroded through. Front bridge bulkhead corroded through. On PS bridge cracked. PS WBT5 air pipe corroded through. Ball protections on PS air pipes WBT4, WBT3, WBT2 corroded through. Ball protection on pipes WBT2 and WBT1 corroded through. Self igniting lights inoperative. Store rooms doors corroded through. Step over deck lines corroded through. Fr ame on hatch coaming corroded through. Damper on hold 2 air vent sized. Paint air vent corroded through. On FCSL bell missing. On FCSL 2 FP air pipes corroded through. Top of the FP tank corroded through. In FP several frames corroded through. Upper platform in FP corroded through. Hold air vent 1 corroded through. Step on steering gear room entrance corroded through. Cooling water line for compressors temporary repaired. Grey water line from pantry leaking. On ME fuel leaking alarm missing. Two fire alarms in ER covered. Cooling water line for ME leaking. AP tank air pipe corroded through. One fire hose leaking. Lifeboat speed insufficient. Abandon drill failed. Maintenance of ship and equipment failed.
02/02/2009
Koper / NASIP
General cargo
7928665
1.710 / Panama / Kylon shipping
Istanbul
Turkey / Bulgarski Koraben Registar / Detained for 4 days.
17 recorded deficiencies.
Chart 1471 missing. Front bridge bulkhead corroded through. ER air vent corroded through. Standard discharge connection flange improper. On FCSL air vent cover dogs missing. FP tank air pipe holed. Top of FP tank buckled. In hold PS several frames and frame corners bent. In hold STB one frame cracked one bent. Bulkheads on both side tanks improperly repaired. Side tanks repaired with concrete. One hatch cover corroded through. In ER six consecutive frames and frame corners bent. In ER grey water line temporary repaired. Top of the AP tank corroded through. On both anchor lights glasses cracked. Stern navigational light cracked.
03/02/2009
Koper / FAVEA
General cargo
8876353
1.766 / Belize / Bass shipping
Ukraine / Russian Maritime Register of Shipping / Detained for 8 days.
8 recorded deficiencies.
Life raft certificate expired. Publications not up to date. Charts missing. Food quantity insufficient. Crew is not equipped with personal protective equipment. Abandon drill failed. Lack of familiarity with GMDSS equipment. ISM emergency preparedness failed.
04/02/2009
Koper / TAMA STAR
Reefer ship
8517358
6.579 / Bahamas / Sea trade
Groningen
Netherlands / Bureau Veritas / Detained for 3 days.
7 recorded deficiencies.
Battery room threshold corroded through. Entrance threshold corroded through. Fresh water gauges made of plastic. Lub oil gauges made of plastic, drain cocks blocked. ME jacketed fuel leak alarm inoperative. Oil filtering equipment inoperative. Fresh water line temporary repaired.
06/02/2009
Koper / MIKHAIL KUZNETSOV
General cargo
9202467
3.376 / St Vincent & Grenadine / Tschudi Ship Management
Estonia / Russian Maritime Register of Shipping / Detained for 4 days.
8 recorded deficiencies.
Bunker certificate missing. Wheelhouse wipers missing. Accommodation bulkhead holed. Bilge dirty. DG No 1 inoperative. Emergency liht inoperative. Lifeboat engine inoperative. DG cannot be synchronised.
10/02/2009
Koper / SVETI SERAFIM
7620201
3.629 / Comoros / Trimpex Union Ltd.
Bulgaria / Russian Maritime Register of Shipping / Detained for 7 days.
30 recorded deficiencies. On wheelhouse clear view screen window missing. Wheelhouse bulkhead corroded through. ER air vent corroded through. ER sky light corroded through. Alleyway bulkhead on boat deck corroded through. Funnel corroded through. Galley bulkhead corroded through. Galley air vent trunk corroded through. In hold 3 STB 8 frames corroded through. In hold 3 FWD gusset plate cracked. In hold 3 aft deck support corroded through. Deck over hold 3 corroded through. Deck over hold 2 corroded through. Deck over deep tank 3 corroded through. Deck over deep tank 8 corroded through. In hold 2 frame corners bent. In hold 2 STB two frames corroded through. In hold 2 beams corroded through. Bulkhead between hold 1&2 corroded through. STB chain pipe cracked. PS chain pipe corroded through. Top of chain locker corroded through. Low level alarm on DO fuel tank disconnected. Deck over ER control room corroded through. Several cooling water lines temporary repaired. On PS ME all jacketed lines twisted. On ME fuel leak alarm inoperative. Line on lub oil pump temporary repaired. Possible illegal discharge valve installed on bilge pump line. ISM maintenance of ship and equipment failed.
13/02/2009
Koper / SOUMAYA – J
General cargo
7118870
2.397 / Togo / ISM Group
Tartous
Syria / International Naval Survey Bureau / Detained for 9 days.
23 recorded deficiencies.
Hull leaks on scupper place. IMO company number missing. Main fire line corroded through. Air condition cables improperly installed through cabins bulkheads. Funnel damper sized. On poop deck outside ladder steps corroded through. Hold air vent cover on front bridge sized. Cover on emergency exit corroded through. On FCSL anchor ball of improper size and shape. Windlass base cracked and corroded through. Top of STB chain pipe damaged. On FCSL 3 air pipes corroded through. Hatch entrance cover on FCSL corroded through. Top of the PS side tanks corroded through. Gusset plates between frames corroded through. Top of the STB side tanks cracked and corroded through. Support corners on web frames detached and damaged. In hold 2 air pipes corroded through. Obsolete OFE outboard line can be used as illegal discharge. Fuel leaks from QCV on settling tank. In steering gear room 3 consecutive frames damaged. Grey water line in steering gear room corroded through.
16/0encies2/2009
Koper / IGARKA
General cargo
8857863
2.426 / Russia / ENECS
Russia / Russian Maritime Register of Shipping / Detained for 10 days.
9 recorded deficiencies. One transponder inoperative. Wheelhouse bulkhead corroded through. Magnetic compass sized in gimble. PS funnel corroded through. Food store air vent corroded through. Four upper corners on hatch coaming damaged. ER main fire line temporary repaired. Piece of main fire line disconnected. ER bilge to be dried and cleaned.
17/02/2009
Koper / CAESAR 1
General cargo
7361659
2.709 / Korea DR / Prompt Allied Management
Syria / Korean Classification Society / Detained for 8 days.
34 recorded deficiencies.
Company IMO number missing. Antifouling certificate missing. Chart 1471 missing. Alarm of navigational lights inoperative. Wheelhouse bulkhead corroded through. Main magnetic compass with air bubble. Air condition cables improperly installed through cabin bulkheads. Lower block on provision derrick corroded through. Funnel dampers sized. Damper on store air vent sized. On poop deck 2 air vents corroded through. Ball protection on B air pipe corroded through. Air pipe on AP tank corroded through. Front bridge bulkhead corroded through. Head of BW III air pipe cracked. Heads of VPU air pipes cracked. PS VPU air pipe corroded through. High tank bulkhead corroded through. In hold 1 gusset plate corroded through 1 cracked. In hold several frames damaged. In hold fuel leaking from manhole. In TD PS 3 air pipes corroded through. In TD PS 4 frames corroded through. One hold access ladder damaged. In hold top of the ballast tank leaking on welded doubler. PS BW II air pipe corroded through. Standard discharge connection flange not as required. Gauge on service tank made of plastic. Possible illegal discharge rubber pipe connected to obsolete OFE outlet. Bilge line corroded through. Abandon drill failed. Lifeboat engine inoperative. ISM maintenance of ship and equipment failed.
23/02/2009
Koper / TAYYAR SENKAYA 1
General cargo
7615957
1.854 / Turkey / ER – mar
Istanbul
Turkey / Turkish Lloyd / Detained for 3 days.
13 recorded deficiencies. Chart 1471 missing. Air condition cables improperly installed through cabins bulkheads. Magnetic compass gimble sized. In hold 2 several frames corroded through. In hold 2 several frames and frames knees damaged. Twin deck in hold 2 cracked. FWD beam in hold 2 corroded through. In FCSL main fire line corroded through. Anchor ball improper size. Brake on hold 1 cargo winch damaged. In ER 5 consecutive frame knees bent. Sewage line temporary repaired. ER bilge dirty.
16/03/2009
Koper / SVETI JERE
General cargo
7120653
1.537 / Panama / Split Ship Management
Croatia / Detained for 7 days.
17 recorded deficiencies. Wheelhouse bulkhead corroded through. Magnetic compass half liquid missing. Funnel corroded through. LO and FO settling tank air pipes corroded through. Deck over ER corroded through. Toilet air vent corroded through. Steering gear air vent corroded through. DBT3 air pipe corroded through. DBT1 air pipe corroded through. ER air vent corroded through. Gauges on DO daily tank , sludge tank and settling tank made of plastic. Hydrophore pipe temporary repaired. On DG2 fuel leaking. Suction line of emergency fire pump temporary repaired. In steering gear room main fire line temporary repaired. In steering gear room grey water line temporary repaired.
25/03/2009
Koper / AFANASIY MATYUSENKO
General cargo
8227783
2.466 / Ukraine / Ukriiflot
Ukraine / Russian Maritime Register of Shipping / Detained for 6 days.
PS boat deck support plate corroded through. Scupper pipe corroded through. Bridge floor plates corroded through. Main magnetic compass with air bubbles. EPIRB installed in wheelhouse. On ER sky light cover corroded through. Alleyway shaft bulkhead corroded through. Deck over emergency generator room corroded through. Monkey deck covered with tarred canvas. Toilet bulkhead on poop deck corroded through. Standard discharge connection flange not as required. Main fire line temporary repaired. Glass on safety light in paint room crashed. FP air pipe corroded through. FCSL deck corroded through. On FCSL 2 bollard bases corroded through. Base frame on hawser pipe corroded through. Fresh water sounding pipe detached from deck. Safety net under gangway missing. Front bridge air vent shaft corroded through. Pipes’ defence on main deck corroded through. Boat deck corroded through. Over speed rods on both MEs fixed with wires. Cooling water on DG1 and DG2 leaking. On DG1 and DG2 fuel return lines disconnected. Quick closing valves on fuel tanks inoperative. STB ME lub oil pump leaking. Main fire pump lines corroded through. Ballast line temporary repaired. Rubber pipes connected to high and low suction valves. Sewage line temporary repaired. ISM -Maintenance of ship and equipment failed.
06/04/2009
Koper / EGEHAN
General cargo- multipurpose