ECE320, Spring 2006,Exam 1 25thJanuary, 2006
Duration 1 hour
Name SOLUTIONS
PID NumberProblem / MaxPoints / Points
1 / 30
2 / 40
3 / 30
Total / 100
Instructions
- Read all the problems first.
- Attempt to solve first the problems you can do-don’t spend too much time on one problem.
- Read carefully the statement of the problems.
- Use the previous page’s back if more space is needed.
- Write neatly and show all the steps, no marks otherwise.
Problem 1. For the circuit below, calculate the load using Thevenin’s theorem.
Solution:
The voltages at nodes A and B can be found by voltage division.
Open Circuit Voltage ()
VAD
VBD
= 0.
Thevenin Impedance ()
Since , no voltage drop appears across terminals A and B; therefore, no current flows through .
.
Problem 2. For a balanced 3-phase circuit below,the source voltage is 208 V. Calculate (1) the real (active) and reactive power of each load, (2) the total real and reactive power of both loads, and (3) the real and reactive power provided by the source. Explain why the source reactive power differs from the total load reactive power. What about the source real power and the total load real power (should they be equal)?
Solution:
Converting delta connected load to star and then considering only a single phase, the circuit will be as shown in figure.
(1)
Total Impedance
We haveA
Using Current DivisionA
A
Load Voltages
V
V
Transmission Line Voltage Drop
A
Load 1
Real PowerkW
Reactive PowerkVAR
Load 2
Real PowerkW
Reactive PowerkVAR
(2)Total Real and Reactive Power of Both Loads:
kW
(3)The Real and Reactive Power Provided by the Source:
kW
kVAR
Source Reactive Power differs from the total load reactive power (which is zero in this case) because it is the power associated with the transmission line.
Transmission Line Reactive Power = 3 (11.94) (59.7) sin (84.2+5.72) = 2.138 kVAR
Or = 3 (59.7 A)2 (0.2 ) = 2.138 kVAR
Since, Transmission Line Real Power = 0
Therefore, Source Real Power = Total Load Real Power.
Problem 3
In a 3-phase system below (Fig. a), the source is 230V and the load (Load_1) is drawing 50kW at 0.866pflagging.
a)A second load (Load_2) is added and its real power is equal to 30kW. What should the pf of the second load be in order for the total pf of the both loads together to be unity?
b)Draw a power triangle diagram to represent the above-obtained real, reactive, and apparent power of the source, Load_1, and Load_2.
Solution:
(a)kW
kVA
kVAR
kW[given]
kW
kVA
Therefore,, since
(b)Power Triangles
Load 1Load 2