SECTION 10 14 00

(MasterFormat 1995 Section: 10440)

INTERIOR SIGNAGE

Display hidden notes to specifier by using “Tools”/”Options”/“View”/”Hidden Text” or

“Word Options”/”Display”/”Hidden Text”

** NOTE TO SPECIFIER **

.

This section is based on the Imagine Sign System of APCO Graphics, Inc., which is located at:

388 Grant St. S.E.

Atlanta, GA 30312

Toll Free: (877) 988-2726

Local: (404) 688-9000

Fax: (404) 577-3847

Email:

Web:

PART 1 GENERAL

1.1SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

A.Complete, updatable image-infused system including identification, personnel, directory, directional and regulatory signage options.

1.2RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

A.Section 10 11 00 - Visual Display Surfaces.

B.Section 10 13 00 - Directories.

C.Section 10 14 26 - Post and Panel / Pylon Signage.

D.Section 10 14 33 - Illuminated Panel Signage.

E.Section 10 14 36 - Non-Illuminated Panel Signage.

1.3REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

A.ANSI A117.1: Providing Accessibility and Usability for Physically Handicap People, 1986 edition.

B.Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA).

C.2010 Standards for Accessible Design (SAD): The updated ADAAG (ADA Accessibility Guidelines), effective on March 15, 2011 and made mandatory on March 16, 2012.

1.4SUBMITTALS

** NOTE TO SPECIFIER ** Delete any items below not applicable for this project.

A.Product Samples: One full size sign sample illustrating the design, construction, colors, typestyles, mounting method and other details as specified.

B.Drawings: Identifying all materials, sizes, construction details, graphics layouts, typestyle specifications and mounting methods.

C.Signage Schedule: Complete with location of each sign and the required copy/text.

D.Sign Program Maintenance Plan:

  1. Manufacturer shall provide details of software and system of color coated paper sign inserts allowing client to update and maintain signage graphics in-house.
  2. Manufacturer shall provide details of an Online Reordering & Maintenance Application whereby the client can submit sign reorders online and store/view relevant project information such as signtype drawings, message schedules and product instructions.

1.5SYSTEM DESCRIPTION

A.Signage under this section is intended to include items for identification, direction, control, and information of building where installed as complete integrated system from a single manufacturer.

B.ADA design requirements:

  1. Provide signage that conforms to the requirements of all regulatory agencies holding jurisdiction.
  2. Comply with all applicable provisions of the 2010 Standards for Accessible Design (the updated ADA Accessibility Guidelines, ADAAG), effective in March 2011. Requirements include, but are not limited to the following:
  3. Tactile copy must be all upper case and raised at least 1/32”. Tactile characters must be sans serif, not italic, not oblique, script or highly decorative.
  4. The stroke width of the upper case “I” has to be 15% of the letter height or less. The character width of the uppercase “O” must be between 55% and 100% of the height of the corresponding uppercase “I”.
  5. The copy height for tactile information must be between 5/8” and 2”. If separate visual characters are provided, raised characters can be ½” and need not contrast with the background.
  6. The distance between characters on tactile copy must be a minimum of 1/8” and a maximum of 4 times the character stroke width. These distances are measured between the closest points of adjacent characters.
  7. Spacing between lines of tactile copy needs to be a minimum of 135% and a maximum of 170% of the corresponding upper case “I” height (measured from baseline to baseline).
  8. Braille must be Grade II and positioned directly below the corresponding raised characters. If text is multi-lined, Braille is placed below the entire boyd of text and separated 3/8” from any other tactile characters and 3/8” minimum from raised borders and decorative elements.
  9. Visual characters and symbols, and their background, are to have a non-glare finish. The color of raised characters must contrast as much as possible with their background to make sure signs are more legible for persons with low vision.
  10. Pictograms, selected from International Standards, are to be located within a 6” vertical void and accompanying text descriptions are to be located directly below the pictogram.

1.6QUALITY ASSURANCE / WARRANTY

** NOTE TO SPECIFIER ** Delete any items below not applicable for this project.

A.Manufacturer: Work required under this section from manufacturer regularly engaged in work of this type and scope for a minimum of 5 years.

B.Product Warranty: Provide manufacturer’s warranty against defects in materials and workmanship for a minimum of 1 year.

C.Samples: One full size sign sample illustrating the design, construction, colors, typestyles, mounting method and other details as specified.

1.7DELIVERY, STORAGE & HANDLING

** NOTE TO SPECIFIER ** Delete any items below not applicable for this project.

A.Package signs to prevent damage during shipment, handling, storage and installation. Products are to remain in their original packaging (unless otherwise specified) until removal is necessary for installation.

B.If installation site is not ready for signage upon delivery, store signs in a dry, air-conditioned environment.

C.Handle signage in accordance with manufacturer’s instructions.

PART 2 PRODUCTS

2.1ACCEPTABLE MANUFACTURERS

A.Signage shall be manufactured by APCO Graphics, Inc. (a.k.a. APCO Signs, APCO Sign Systems or APCO USA), at 388 Grant Street SE, Atlanta, GA 30312. Toll Free: 877.988.2726.

2.2ACCEPTABLE PRODUCT

A.Imagine – Image Infused Sign Solution (featuring the FullView modular frame system)

B.Requests for substitutions will be considered only within the provisions of Section 01 25 00 and must conform to the quality, capabilities, performance and design intent as the specified APCO product.

2.3PRODUCT STANDARDS

A.General:

  1. Sign system shall feature image-focused solutions for all required sign types, including but not limited to wall mounted personnel signs, work station signs, primary room identification, directories, directionals, overhead signs, projection wall signs, free standing signs, restroom signs, regulatory and information signs, stair signs and changeable slide conference room signs. All signs within the system must feature the same family of components and convey a uniform look throughout.

B.Features:

  1. Images, Photographs and Patterns: All images, patterns and/or photographs shall be digitally printed and retained within a modular frame system to facilitate updates and maintenance. Plaque signs will not be acceptable.
  2. Modularity: All display components, including images, photographs, patterns, prints, messages and graphics, must be 100% modular and updatable. All prints must be protected by a removable, front-loading non-glare lens for scratch and tamper resistance.
  3. Sign Frames: Sign frame assemblies shall be comprised of aluminum extrusions with a PVC-free core material rigid enough to support the sign’s display/insert material.
  4. Sign Depth: Wall mounted signs 17inches wide or less shall feature a maximum depth of7/16 of an inch. No wall mounted signs should feature a depth greater than 11/16 of an inch.
  5. In-House Signage Updates: Manufacturer must provide a free, downloadable software with templates allowing the end user to produce laser or inkjet-printed replacement inserts for his/her sign program in-house.
  6. Online Reordering: Manufacturer must offer an online reordering application allowing the owner to view his/her sign program drawings & specifications and submit sign reorders online 24/7.
  7. Mounting: Signs must be able to easily accommodate installation via fully concealed mechanical fasteners.
  8. Manufacturer must offer a library of images, patterns and photographs available for incorporation within the signage design.

C.Graphics and Typography: As selected from manufacturer’s standards. Reference sign drawings.

D.Colors and Finishes: As selected from manufacturer’s standards. Reference sign drawings.

E.ADA Compliance: Sign system shall comply with all applicable provisions of the 2010 Standards for Accessible Design (the updated ADA Accessibility Guidelines, ADAAG), effective in March 2011. This includes requirements regarding which sign types require Braille/tactile features, character heights, raised character spacing, raised character stroke width, color contrast and installation locations and mounting heights within the facility.

F.Materials and Construction:

  1. Sign assemblies shall be comprised of an extruded aluminum frame and an inner core rigid enough to properly support the display/insert material. Frames must be PVC free.
  2. Aluminum frame extrusions shall be extruded in the USA.
  3. Non-glare lenses protecting all images, patterns, graphics and messages shall be GREENGUARD Certified.
  4. Braille/Tactile Components shall be PETG-backed photopolymer with raised characters and Braille of minimum 1/32 of an inch depth. PETG-backed Braille/tactile plaques shall contain a minimum of 40% recycled content.
  5. Graphics, images, patterns and messages are as per sign drawings and should be easily updatable without the need to replace the entire sign assembly.
  6. Fasteners: Signs shall be able to accommodate fully concealed mechanical

fasteners.

2.4SIGN SYSTEM DETAILS

Reference drawings for colors, finishes, images, patterns, sizes and details. Reference signage schedule for graphics/copy specifications.

A.Aluminum FullView Frame Details

  1. Frame Shape

** NOTE TO SPECIFIER ** Delete the frame shapes not applicable to this project.

  1. Square: FVES(V)
  2. Radius: FVER(V)
  3. Bevel: FVEB(V)
  4. Contour: FVEC(V)
  1. Frame Finish
  2. Natural Satin Anodized
  3. Acrylic Polyurethane Finish – Manufacturer’s Standard Color
  4. Acrylic Polyurethane Finish – Custom Color
  5. General Wall Mounting/Installation Method:
  6. Vinyl Tape (V)
  7. Concealed Mechanical Fasteners (MF)
  8. Vinyl Tape and Silicone Adhesive (SA)

B.Imagine Image, Pattern and/or Photograph Details

  1. Images/Photographs incorporated within the sign program design:

** NOTE TO SPECIFIER ** Delete the images/photographs not applicable to this project. Custom and/or customer-supplied images/photographs are also possible.

  1. Floral – Purple Tulips (FL-01)
  2. Floral – Yellow Daisies (FL-02)
  3. Floral – Orange Lilies (FL-03)
  4. Floral – White Mum (FL-04)
  5. Floral – Blue Myosotis (FL-05)
  6. Sky – Scattered Clouds (SK-01)
  7. Sky – Purple Sky (SK-02)
  8. Sky – Puffy Clouds (SK-03)
  9. Sky – Orange Sunset (SK-04)
  10. Sky – Sun Through Clouds (SK-05)
  11. Water – Water Refraction (WA-01)
  12. Water – Fern Water Droplet (WA-02)
  13. Water – Water Drops (WA-03)
  14. Water – Soft Blue Waves (WA-04)
  15. Water – Ocean Surf (WA-05)
  16. Grass – Grass (GR-01)
  17. Grass – Bamboo (GR-02)
  18. Grass – Dew on Grass (GR-03)
  19. Grass – Wheat Field (GR-04)
  20. Grass – Black & White Grass (GR-05)

i. with Color Change: ______

  1. Leaves – Orange Maple Leaves (LE-01)
  2. Leaves – Skeletal Leaves (LE-02)
  3. Leaves – Palm Branch (LE-03)
  4. Leaves – Leaf Imprints (LE-04)
  5. Leaves – Autumn Leaves (LE-05)
  6. Stones / Rocks – Grey River Stones (SR-01)
  7. Stones / Rocks – Tan Slate (SR-02)
  8. Stones / Rocks – Red Canyon (SR-03)
  9. Stones / Rocks – Grey Slate (SR-04)
  10. Stones / Rocks – Limestone (SR-05)
  11. Pets – Dog (PE-01)

i.with Color Change: ______

  1. Pets – Ferret (PE-02)

i.with Color Change: ______

  1. Pets – Kitten (PE-03)

i.with Color Change: ______

  1. Pets – Parrott (PE-04)

i.with Color Change: ______

  1. Pets – Bunny (PE-05)

i.with Color Change: ______

  1. Landscape – Mountain Stream (LA-01)
  2. Landscape – Flowers & Mountains (LA-02)
  3. Landscape – Green Meadow (LA-03)
  4. Landscape – Waterfall (LA-04)
  5. Landscape – Fog in the Woods (LA-05)
  6. Architectural – Modern Shapes (AR-01)

i.with Color Change: ______

  1. Architectural – Architectural Lines (AR-02)

i.with Color Change: ______

  1. Architectural – Skylight (AR-03)

i.with Color Change: ______

  1. Architectural – Glass Wall (AR-04)

i.with Color Change: ______

  1. Architectural – Columns (AR-05)
  2. Wood – Bamboo Strips (WO-01)
  3. Wood – Rosewood (WO-02)
  4. Wood – Cork (WO-03)
  5. Wood – Ebony (WO-04)
  6. Wood – Burled Maple (WO-05)
  7. Art – Colorful Squares (AT-01)
  8. Art – Impressionism (AT-02)
  9. Art – Colorful Shapes (AT-03)
  10. Art – Paint Splatter (AT-04)
  11. Art – Cubism (AT-05)
  12. Children – Crayons (CH-01)
  13. Children – Baby Foot (CH-02)
  14. Children – Hand Prints (CH-03)
  15. Children – Adhesive Bandage (CH-04)
  16. Children – Blocks (CH-05)
  17. Custom/Customer Supplied: ______
  1. Patterns/Designs incorporated within the sign program design:

** NOTE TO SPECIFIER ** Delete the patterns/designs not applicable to this project. Custom and/or customer-supplied patterns/designs are also possible.

  1. Circles / Dots (PCD-01)
  2. Circles / Dots (PCD-02)
  3. Circles / Dots (PCD-03)
  4. Circles / Dots (PCD-04)
  5. Circles / Dots (PCD-05)
  6. Filigree (PFL-01)
  7. Filigree (PFL-02)
  8. Filigree (PFL-03)
  9. Filigree (PFL-04)

i. Color Change: ______

  1. Filigree (PFL-05)
  2. Scribble (PSC-01)
  3. Scribble (PSC-02)
  4. Scribble (PSC-03)
  5. Scribble (PSC-04)
  6. Scribble (PSC-05)
  7. Vertical Lines (PVL-01)
  8. Vertical Lines (PVL-02)
  9. Vertical Lines (PVL-03)
  10. Vertical Lines (PVL-04)
  11. Vertical Lines (PVL-05)
  12. Soft Squares (PSS-01)
  13. Soft Squares (PSS-02)
  14. Soft Squares (PSS-03)
  15. Soft Squares (PSS-04)
  16. Soft Squares (PSS-05)
  17. Hatch (PHA-01)
  18. Hatch (PHA-02)
  19. Hatch (PHA-03)
  20. Hatch (PHA-04)

i.Color Change: ______

  1. Hatch (PHA-05)
  2. Fractal (PFR-01)
  3. Fractal (PFR-02)
  4. Fractal (PFR-03)

i.Color Change: ______

  1. Fractal (PFR-04)
  2. Fractal (PFR-05)
  3. Sticks (PST-01)
  4. Sticks (PST-02)
  5. Sticks (PST-03)
  6. Sticks (PST-04)
  7. Sticks (PST-05)
  8. Rectangles (PRE-01)
  9. Rectangles (PRE-02)
  10. Rectangles (PRE-03)
  11. Rectangles (PRE-04)
  12. Rectangles (PRE-05)

i. Color Change: ______

  1. Wavy Lines (PWL-01)

i. Color Change: ______

  1. Wavy Lines (PWL-02)
  2. Wavy Lines (PWL-03)
  3. Wavy Lines (PWL-04)
  4. Wavy Lines (PWL-05)
  5. Floral Vines (PFV-01)
  6. Floral Vines (PFV-02)
  7. Floral Vines (PFV-03)
  8. Floral Vines (PFV-04)
  9. Floral Vines (PFV-05)
  10. Leaf Swirl (PLS-02)

i. Color Change: ______

  1. Leaf Swirl (PLS-03)
  2. Leaf Swirl (PLS-04)
  3. Leaf Swirl (PLS-05)
  4. Plaids (PPL-01)
  5. Plaids (PPL-02)
  6. Plaids (PPL-03)
  7. Plaids (PPL-04)

i.Color Change: ______

  1. Plaids (PPL-05)
  2. Leaf (PLE-01)
  3. Leaf (PLE-02)
  4. Leaf (PLE-03)
  5. Leaf (PLE-04)
  6. Leaf (PLE-05)

i.Color Change: ______

  1. Custom / Customer Supplied: ______

C.Core Sign Types and Quantities

** NOTE TO SPECIFIER ** Make sign type selections and indicated quantities as applicable. Custom sizes and sign configurations are available.

  1. IGFV-A (4.08”h x 4.25”w Personnel Sign)
  2. Quantity: _____
  3. IGFV-A1 (5.25”h x 6”w Personnel Sign)
  4. Quantity: _____
  5. IGFV-A2 (5.25”h x 8.5”w Personnel Sign)
  6. Quantity: _____
  7. IGFV-B (9.5”h x 8.5”w Room/Suite ID)
  8. Quantity: _____
  9. IGFV-B1 (8.25”h x 6”w Room/Suite ID)
  10. Quantity: _____
  11. IGFV-B2 (8.75”h x 8.5”w Room/Suite ID)
  12. Quantity: _____
  13. IGFV-B3 (11.5”h x 8.5”w Room/Suite ID)
  14. Quantity: _____
  15. IGFV-C (5.25”h x 8.5”w ADA ID)
  16. Quantity: _____
  17. IGFV-D (9.8”h x 8.5”w Conference Room ID)
  18. Quantity: _____
  19. IGFV-E (11.5”h x 8.5”w Restroom Sign)
  20. Quantity: _____
  21. IGFV-H (11.25”h x 8.5”w Stairs Sign)
  22. Quantity: _____
  23. IGFV-J (8.5”h x 8.5”w Regulatory Sign)
  24. Quantity: _____
  25. IGFV-K (14.25”h x 11”w Emergency Plan)
  26. Quantity: _____
  27. IGFV-L (14.25”h x 8.5”wMeetings/Notices/Announcements)
  28. Quantity: _____
  29. IGFV-M (20”h x 11”w Directional)
  30. Quantity: _____
  31. IGFV-N (26”h x 17”w Directional)
  32. Quantity: _____
  33. IGFV-O (8.5”h x 48”w Overhead)
  34. Quantity: _____
  35. IGFV-P (66”h x 11”w Free Standing)
  36. Quantity: _____
  37. IGFV-R(11.25”h x 8.5”w Projection Wall Mount)
  38. Quantity: _____

D.Graphics:

  1. Type Sizes: Selected from manufacturer's standard sizes indicated in SCHEDULE for particular units; meet ADA requirements for letter proportions and sizes.
  2. Typography: Reference signage schedule and drawings for details. Font(s) selected from manufacturer’s standards unless otherwise specified. All text and graphics shall be a true representation of the typeface(s) and/or graphicsspecified. Letter spacing and interline spacing shall be set by the manufacturer.

NOTE TO SPECIFIER ** Delete typeface(s) not required.

  1. HelveticaNeue-Roman (HR)
  2. Futura Book (FUB)
  3. Arial (AR)
  4. Frutiger-Normal (F55)
  5. Myriad Pro (MP)
  6. Typeface(s) as indicated in SCHEDULES Article and Drawings.

NOTE TO SPECIFIER ** Delete type code(s) not required.

  1. Type Code(s): Uppercase.
  2. Type Code(s): Initial caps.
  3. Type Code(s): Combination.
  4. Type Code(s): Indicated in SCHEDULES Article.
  5. Imprint Colors: Selected by Architect from manufacturer's standard direct-print colors and indicated in SCHEDULE; color contrast background colors in accord with ADA requirements.
  6. Copy/Message List: Indicated in SCHEDULE.
  7. Reference drawings and Signage Schedule for details.
  8. All text and graphics shall be a true representation of typeface(s) and/or graphics specified.

2.5FABRICATION

A.Fabricate units as per specifications and details indicated on reviewed drawings.

B.All fabrication must take place in the USA.

C.Include product instructions sheets for installation and removal/replacement of insert components.

PART 3 EXECUTION

3.1EXAMINATION

A.Do not begin installation until substrates have been properly prepared.

B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2PREPARATION

A.Clean surfaces thoroughly prior to installation.

B.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3INSTALLATION

A.Install products in accordance with manufacturer’s instructions, in locations and with mounting methods as specified in sign and location drawings.

B.Square, plumb and level all installed products.

C.Install all signage in accordance with the 2010 Standard for Accessible Design (SAD) effective in March 2011, and any applicable local regulations and/or codes.

D.Upon completion of the work, sign installer shall remove any unused products, materials, packaging and debris from the installation site.

3.4CLEANING

A.Clean all exposed surface not more than 48 hours prior to Date of Substantial Completion in accordance with manufacturer’s written cleaning instructions.

3.5PROTECTION

A.Protect installed products until completion of project.

B.Touch-up, repair or replace damaged products before Substantial Completion.

3.6SIGN SCHEDULES

A.Refer to Signage Schedule and Drawings for sizes, locations, sign types, layouts, typography specifications, sign text/copy and sign graphics.

END OF SECTION

10 14 00-1