Home Inspection Report

1

© 2002 Copyright DevWave Software Inc., all rights reserved.

TABLE of CONTENTS

TABLE of CONTENTS 2

PURPOSE & SCOPE 3

EXCLUSIONS AND LIMITATIONS 4

STRUCTURAL SYSTEM 6

EXTERIOR 8

LANDSCAPE & SITE DRAINAGE 11

ROOF SYSTEM 12

PLUMBING SYSTEM 14

ELECTRICAL SYSTEM 16

HEATING SYSTEM 18

AIR CONDITIONING SYSTEMS 20

INTERIOR 22

INSULATION & VENTILATION 24

FIREPLACES & SOLID FUEL BURNING APPLIANCES 26

CREIA STANDARDS OF PRACTICE 27

REPORT DATE:
February 12, 2003 / PROPERTY LOCATION:
3253 NW 59th St.,
San Jose, CA 93467
PREPARED FOR:
Pick E. Customer
14567 Wendtwood
San Mateo, CA 93456
Phone: 555-567-4567 / PREPARED BY:
Defect Ferret Inspections
12345 – Walton
San Mateo, CA 93456
Phone: 555-567-5555

This report summarizes the verbal briefing delivered after our inspection conducted February 12, 2003 at the above address. The weather was sunny at the time of the inspection.

PURPOSE & SCOPE

This firm endeavors to perform all inspections in substantial compliance with the standards of practice of the California Real Estate Inspection Association® (CREIA). Our report documents observations of systems and components that, in the professional opinion of the inspector authoring this report, are significant material defects that affect the value, desirability, habitability, or safety of the residence. Style or aesthetics have not been considered in determining whether a specific system structure or component is defective.

Inspections performed to CREIA® standards are not technically exhaustive. The inspection and this report are limited to the primary residence, its associated primary parking structure, and only those specific systems, structures and components that were present and visually accessible at the time of the inspection. Systems or structures outside of these parameters are included only if agreed to by the inspector and client, in writing, prior to commencement of the inspection process.

Although every reasonable effort was made to discover and correctly interpret indications of previous or ongoing defects that may be present, a standard real estate inspection is a non-invasive physical examination, designed to determine conditions, as they exist at the time of inspection. The inspection results are offered as an opinion only and no responsibility is assumed by the inspector or inspection company for the actual condition of the building or property examined at the time of the inspection. Likewise, no guarantee of future performance is implied. Additional information as to the scope of the inspection standards as well as limitations, exceptions and exclusions are explained below and at the beginning and end of every section of the report.

Components and systems are operated only with normal user controls and as conditions permit. If our inspector has the skills and knowledge to readily identify the cause of a material defect, that cause has been reported herein. If the cause is not readily apparent, the suspected cause or reason why the system or component is at or near end of expected service life has been reported. This report may contain recommendations regarding conditions reported or recommendations for further evaluation by appropriate persons. When systems or components designated for inspection in the CREIA® standards are present but are not inspected or are excluded, the reason the item was not inspected or has been excluded is reported.

EXCLUSIONS AND LIMITATIONS

The CREIA® Standards of Practice are the minimum standards for any home inspection performed by members of CREIA® and apply equally to mandatory and optional areas to be inspected and conditions reported. They are not technically exhaustive and do not identify concealed conditions or latent defects. Unless specifically agreed otherwise between the inspector and client, inspectors are NOT required to determine the condition of any system or component that is not readily accessible; concealed from view or cannot be inspected due to circumstances beyond the control of the inspector. Inspectors are not required to determine the remaining service life of any system or component; the strength, adequacy, effectiveness or efficiency of any system or component; causes of any condition or deficiency; methods materials or cost of corrections; future conditions including but not limited to failure of systems and components; the suitability of the property for any specialized use; compliance with regulatory codes, regulations, laws or ordinances; the market value of the property or its marketability; the advisability of the purchase of the property; the presence of potentially hazardous plants or animals including but not limited to wood destroying organisms or diseases harmful to humans; the presence of any environmental hazards including, but not limited to toxins, carcinogens, noise, and contaminants in soil, water or air; the effectiveness of any system installed or methods utilized to control or remove suspected hazardous substances; the operating costs of any systems or components and the acoustical properties of any systems or components.

Inspectors are NOT required to operate any system or component that is shut down or otherwise inoperable; any system or component which does not respond to normal operating controls or any shut off valves.

Inspectors are NOT required to offer or perform any act or service contrary to law; offer or perform engineering services or work in any trade or professional service other than home inspection.

Our inspectors are NOT required to use any special equipment to examine any system, structure or component of a residence nor probe or exert pressure on any components system or structure.

We DO NOT offer or provide warranties or guarantees of any kind unless clearly explained and agreed to by both parties in a formal pre-inspection agreement.

We DO NOT examine or evaluate the acoustical or other nuisance characteristics of any system, structure or component of a building, complex, adjoining properties or neighborhoods.

We DO NOT perform due diligence investigations for our clients. In other words, we DO NOT research the history of a property; report on its potential for alterations, modification, extendibility, or its suitability for a specific proposed use or occupancy. Likewise, we DO NOT obtain or review information from any third-parties including, but not limited to: government agencies (such as permits), components or system manufacturers (including product defects, recalls or similar notices), contractors, managers, sellers, occupants, neighbors, consultants, homeowner or similar associations, attorneys, agents or brokers.

We DO NOT examine or evaluate the fire-resistive qualities of any system, structure or component of residences that we inspect.

Inspectors are NOT required to examine every individual component of a system or residence when those components are replicated, including, but not limited to: doors, windows, switches and receptacles. In such cases, a representative sampling is taken in order to examine such systems, structures or components of a residence.

Inspectors are NOT required to inspect underground items including, but not limited to underground storage tanks or other underground indications of their presence, whether abandoned or active.

Inspectors are NOT required to determine the year or construction or installation date of any system, structure or component of a residence, and are NOT required to differentiate between original construction and subsequent renovations or replacements, additions or improvements.

Unless agreed to by the inspector and client beforehand, inspectors are NOT required to enter and inspect detached structures, other than primary garages and carports, not entered in accordance with the CREIA® Standards of Practice.

Inspectors are NOT required to inspect common areas, systems, structures or components of common areas within common interest developments as defined in California Civil Code Section 1351 et seq., or those found in other multi-unit housing such as duplexes.

Inspectors are NOT required to perform any procedure or operation which will, in the opinion of the inspector, likely be dangerous to the inspector or others or damage the property, its systems or components.

Inspectors are NOT required to move suspended ceiling tiles, personal property, furniture, floor or wall coverings, window coverings, equipment, plants, soil, snow, ice, water, debris or vegetation which obstructs visibility or access. Likewise inspectors do not dismantle any system or component, except as explicitly required by the CREIA® Standards of Practice.

Our inspectors are NOT required to enter under-floor crawlspaces or attics that are not readily accessible nor any area which will, in the opinion of the inspector, likely be dangerous to the inspector or others persons or damage the property or its systems or components.

Our inspectors are NOT required to operate or evaluate any recreational system, structure or component.

Our inspectors are NOT required to operate or evaluate low voltage electrical (less than single-phase line voltage, typically 120-volts), antennas, security systems, cable or satellite television, telephone, remote controls, radio controls, timers, intercoms, computers, photo-electric, motion sensing, or other such similar non-primary electrical power devices, components or systems.

We do not limit our inspectors from examining other systems and components or including other inspection services. Likewise, if the inspector is qualified and willing to do so, an inspector may specify the type of repairs to be made. The inspector may also exclude those systems or components that a client specifically requests not be included within the scope of the inspection. If systems or components are excluded at the request of the client they are listed herein.

STRUCTURAL SYSTEM

In accordance with the CREIA® standard of practice pertaining to foundations, basements and under-floor areas, this report describes the foundation and other support components, under-floor ventilation, location of under-floor access openings, wood separation from soil, and the presence of seismic anchoring and bracing components. This section also describes the floor, wall, ceiling and roof structures and the method used to inspect any accessible attics and under floor crawlspace areas. The presence of drainage systems or sump pumps within the foundation footprint is reported in the Plumbing System section.

COMPONENT DESCRIPTION

The subject residence is a two story detached, wood frame, single family dwelling, originally built as a one-story bungalow about 1939, but extensively remodeled in 1999 into a two-story craftsman-style home. The residence has four bedrooms, one kitchen, two-and-three-quarter bathrooms and a partially finished basement, with the remainder of the home over crawlspaces. The structure is typical platform framing of 2 by 10 floor joists on 16-inch centers and the floors are sheathed with a combination of plywood and one-by sheathing on the first floor and an unknown decking concealed by floor coverings on the second floor. Floor joists for the family room are 2 X 10 TJI type, as are those beneath the living room bump out. We presume the same type have been used beneath the second floor and the west side bump out. Wall framing is 2 by 4 studs on 16-inch centers sheathed with a combination of oriented strand board (OSB) and one-by sheathing in the first-floor and OSB on the second floor. The roof is a manufactured truss assembly with 2 by 4 ceiling joists and 2 by 6 rafters on 24-inch centers sheathed with plywood sheathing.

The foundation is conventional reinforced concrete design. Accessible crawlspaces have been added at both ends of the original foundation to accommodate about five additional feet added at the north side and roughly 3ft. added at the south side, and there is an inaccessible crawlspace at the west side beneath the stairwell bump-out.

The crawlspaces and attic were inspected using a flashlight. The crawlspace access ports were at an exterior hatch beneath the front porch at north side and a foundation hatch well beneath the deck at the south side. The attic access location was a ceiling hatch in the master bedroom closet.

OBSERVATIONS

ATTENTION: We noted a foundation crack at the west-center of the foundation, beneath the electric meter. All residential foundations settle to some degree and will crack over the lifespan of a home. Such movement, and the typical minor curing cracks that accompany it, is not considered structurally significant, unless related to recent flooding, seismic activity or there is horizontal cracking or other indications of horizontal/lateral displacement of more than 1/4 inch. This crack was vertical, smaller than 1/4 inch, has little or no displacement and has not caused cracks or separation in the framing or at any interior wall or ceiling surfaces that we observed.

It is our opinion that this foundation has most-probably reached final compaction and, barring any unforeseen flooding or seismic event, is not likely to settle or crack further. If desired, the crack can be easily repaired using an injected epoxy. The client should understand that this is the assessment of a home inspector - not a professional engineer - and that, despite this assessment, there is no way we can provide any guaranty that this foundation will never develop additional cracks or settle further. If the client is at all uncomfortable with this condition or our assessment of it, we suggest that a professional engineer be consulted to independently evaluate the crack prior to making a final purchase decision.

IMPORTANT: We found debris (construction scraps, old form boards, trash) in the north crawlspace. This is not only unsafe but is conducive to infestation by vermin or wood-destroying insects. We recommend sanitizing the crawlspace by removing all debris including any form boards left over from the construction process. Once completely cleaned out the only thing remaining on the floor of the crawlspace should be a properly applied and intact vapor barrier.

IMPORTANT: There is no vapor barrier capping the soil under this home in the south crawlspace. We recommend that this be corrected immediately. This is important because the barrier limits the amount of moisture that can evaporate out of the soil into the crawlspace. Even in well-ventilated crawlspaces too much moisture can be a problem, if the normally prescribed vents that are used can't dissipate it rapidly enough. High humidity can result in mold and rot that lead to infestation by wood-destroying insects and eventually structural damage.

A vapor barrier will not prevent extreme flooding, but when properly applied can reduce the amount of moisture the home is exposed to if the crawlspace floods with only a few inches of water. A proper vapor barrier consists of black, 6-mil polyethylene sheeting and must be applied from wall to wall of the foundation. It should cap the footer and lay tightly against the sidewalls, overlapping at least a foot at all adjoining sheets and be tightly sealed around the base of support piers. Ideally, the barrier is secured to the foundation walls with pressure-treated battens or adhered with expanding polyurethane foam and overlaps at adjoining sheets are sealed with waterproof tape. Additionally, the barrier should be applied with some slack, so it can float free without separating and still inhibit evaporation, if minor flooding occurs.