Unclassified

This message was modified for posting

021923Z NOV 10

FM COMSUBPAC PEARL HARBOR HI//N43//

TO SUBFOR

INFO RHMFIUU/COMSUBLANT NORFOLK VA

RUCBKMC/COMSUBLANT NORFOLK VA

RHMFIUU/COMNAVSEASYSCOM WASHINGTON DC

RULSSEA/COMNAVSEASYSCOM WASHINGTON DC

RHMFIUU/NAVSURFWARCEN SHIPSYSENGSTA PHILADELPHIA PA

RHMFIUU/NAVICP MECHANICSBURG PA

RHMFIUU/NAVSHIPYD AND IMF PUGET SOUND WA

RHMFIUU/NAVSHIPYD AND IMF PEARL HARBOR HI

RUHEMCR/NAVSHIPYD AND IMF PEARL HARBOR HI

RHHMDBA/COMSUBPAC PEARL HARBOR HI//N43//

UNCLAS //N04730//

MSGID/GENADMIN/COMSUBPAC/-/OCT//

SUBJ/(SUBS) ANALOX SUB MKII P CALIBRATION //

REF/A/MSG/NAVSURFWARCEN/201854ZOCT2010//

REF/B/DOC/MRC/A8 9TFF N//

REF/C/DOC/MRC/98 A022 N//

REF/D/DOC/SWFPAC/LCP-CAB-239/1AUG2010//

NARR/REF A IS NAVSURFWARCEN MESSAGE FOR ANALOZ SUB MK II P CALIBRATION.

REF B IS MAINTENANCE REQUIREMENT CARD FOR ANALOX SUB MKIIP COMPARISON CHECK/DISPOSITION.

REF C IS MAINTENANCE REQUIREMENT CARD FOR ANALOX SUB MKIIP DISPOSITION.

REF D IS STRATEGIC WEAPONS FACILITY PACIFIC LOCAL CALIBRATION PROCEDURE//

GENTEXT/REMARKS/

1. THIS IS A COMBINED COMSUBLANT/COMSUBPAC MESSAGE.

2. REF A IS QUOTED BELOW IN ITS ENTIRETY. ADDRESSEES HAVE BEEN R 201845Z OCT 10 ZYB

SUBJ/(SUBS) ANALOX SUB MKII P CALIBRATION/

REF/A/DOC/MRC/A8 9TFF N/

REF/B/DOC/MRC/98 A022 N/

REF/C/DOC/SWFPAC/LCP-CAB-239/1AUG2010/

NARR/REF A IS MAINTENANCE REQUIREMENT CARD FOR ANALOX SUB MKIIP

COMPARISON CHECK/DISPOSITION.

REF B IS MAINTENANCE REQUIREMENT CARD FOR ANALOX SUB MKII P DISPOSITION.

REF C IS STRATEGIC WEAPONS FACILITY PACIFIC LOCAL CALIBRATION PROCEDURE/

E-mail for POC information.

1. PURPOSE: TO NOTIFY THE SUBMARINE FLEET THAT A LOCAL CALIBRATION PROCEDURE (LCP) HAS BEEN DEVELOPED BY STRATEGIC WEAPONS FACILITY PACIFIC (SWFPAC) TO SUPPORT THE ANALOX SUB MKIIP.

2. BACKGROUND: THE ANALOX SUB MKII P HAS A MAXIMUM SERVICE LIFE OF 12 MONTHS BEFORE REQUIRED FACTORY CALIBRATION MUST BE PERFORMED. REF A AND REF B CALL FOR THE ANALOX SUB MK II P TO BE CALIBRATED VIA THE NAVICP DEPOT LEVEL REPAIRABLE (DLR) PROGRAM. NSWCCD PHILADELPHIA CODE 926 (ISEA FOR ATMOSPHERE CONTROL AND MONITORING), HAS REVIEWED REF C AND DETERMINED THAT IT IS EQUIVALENT TO FACTORY CALIBRATION.

3. SUBMARINES IN THE PUGET SOUND REGION MAY BEGIN TURNING THE ANALOX SUB MKIIP INTO THEIR APPROPRIATE CALIBRATION FACILITY (SWFPAC FOR 726 CLASS AND PSNS FOR SEAWOLF CLASS AND 688 CLASS TEMPORARILY HOMEPORTED IN PSNS) FOR CALIBRATION WHEN REQUIRED BY EITHER REF A OR REF B EFFECTIVE IMMEDIATELY.

4. THIS MESSAGE WILL REMAIN IN EFFECT UNTIL REF C IS STANDARDIZED FOR USE AT MULTIPLE NAVY CALIBRATION FACILITIES. ECD FOR THIS ACTION IS JANUARY 31, 2011. REF A AND REF B WILL THEN BE REVISED BY PSNS TO DIRECT ALL SUBMARINES TO TURN THE ANALOX SUB MKII P INTO THEIR LOCAL CALIBRATION FACILITY.

5. NAVSEA CODES 05Z42 (ATMOSPHERE CONTROL AND MONITORING TECHNICAL WARRANT HOLDER) AND PMS 392T (IN-SERVICE HM&E SYSTEMS ENGINEERING TECHNICAL WARRANT HOLDER) CONCUR WITH THIS MESSAGE.

6. REQUEST TYCOMS TO READDRESS TO SHIPS.

Page 2 of 2