1) Machines and Equipments for the Dept. of Mechanical Engineering.

Turbomachinery lab:

Centrifugal Pump Demonstration Unit (FM50):

Specifications: Make: Armfield

The pump should comprise of a water reservoir, pump, control valve, relief valve and inter- connecting pipework, all mounted on a stainless steel base.It should be equipped with electronic measurement sensors for pump head pressure, suction, flow-rate and water temperature. The pump volute should be transparent for visibility. It should be capable of being linked to a PC via the IFD7 interface unit.Software providing full instructions for setting up, operating, calibrating and performing the teaching exercises should be provided along with the provision for logging, processing and displaying data graphically.

Gear pump (FM52)

Specifications: Make: Armfield

The pump should comprise of a water reservoir, pump, control valve, relief valve and inter- connecting pipework, all mounted on a stainless steel base.It should be equipped with electronic measurement sensors for pump head pressure, flow-rate and water temperature.The pump head should be transparent for visibility.It should be capable of being linked to a PC .Software providing full instructions for setting up, operating, calibrating and performing the teaching exercises should be supplied. Facilities should be provided for logging, processing and displaying data graphically.

Plunger Pump Demonstration Unit((FM53):

Specifications: Make: Armfield

The pump should comprise of a water reservoir, pump, control valve, relief valve and inter- connecting pipework, all mounted on a stainless steel base.The pump should include a sprung loading valve and a needle valve for loading the pump.It should be equipped with electronic measurement sensors for cylinder pressure, plunger position, pump outlet pressure and cumulative flow. It should have the facility for Pulsation damping.The pump head should be transparent for visibility.It should be capable of being linked to a PC .

Software providing full instructions for setting up, operating, calibrating and performing the teaching exercises should be supplied. Facilities should be provided for logging, processing and displaying data graphically.

Turbine Service Unit(FM6X)

Specifications: Make: Armfield

Capacity: 28 litres.
Max. flow rate: 20 litres per minute Max head: 30m

It should provide suitable water supply for testing a range of different turbines with flow meter, pump, brake and dynamometer controlled form software. It should have the provision for linking to a computer via a USB interface and should be supplied with full education software package including comprehensive results processing and help facilities.

Reaction Turbine(FM61)

Specifications: Make: Armfield

The module should effectively demonstrate the operating principles of a reaction turbine.
There should be provision for connection to a PC via the turbine service unit and a USB interface console.

Pelton Turbine(FM62)

Specifications: Make: Armfield

The module should effectively demonstrate the operating principles of an impulse turbine. There should be provision for connection to a PC via the turbine service unit and a USB interface console.

FM63 Propeller Turbine-

Specifications: Make: Armfield

The Unit should consists of a 75 litre water reservoir, a circulating pump capable of producing 14m head at 4.4 litres/second. It should have the provision for loading by a magnetic brake unit, controlled directly from a PC. It should be supplied with full education software package including comprehensive results processing and help facilities.

UNIVERSAL VIBRATION APPARATUS:

Make : TECHQUIPMENT

Electrical supply: Single-Phase, 230V/110V, 50 Hz

Sound Level(all product): Less than 70 dB(A)

The apparatus should have provision for experiments on the following.

Simple pendulum, Compound pendulum, Center of percussion, Determination of acceleration due to gravity by means of a Kater (reverse) pendulum., Bifilar suspension., Mass- spring system., Torsional oscillation of a single rotor, Torsional oscillation of a single rotor with viscous damping, Torsional oscillation of two rotor system, Transverse vibration of a beam with one or more bodies attached, Undamped vibration absorber, Forced vibration of a rigid body-spring system with negligible damping, Free damped vibrations of a rigid body-spring system, Forced damped vibrations of a rigid body-spring system.

NOISE METER:

Specification:

Display : 3 ½ digitals liquid large LCD display (1999 Counts).

Resolution: 0.1 dB

Frequency range : 31.5 Hz – 8 kHz.

Sampling range : 2.5 times per second.

Microphone : ½ inch Electret Condenser microphone.

Accuracy : ±1.5 dB (ref 94 dB @ 1 kHz).

Lever range : LO: 30 – 80 dB; Med: 50 – 100 dB; Hi: 80 – 130 dB.

Analog AC output : Output Voltage: 1 Vrms (at full scale).

Analog DC output : Output Voltage: 10 mV/dB.

Dynamic range : 50dB.

Power supply : Standard 9V DC battery.

DC Adaptor Socket : 9V (8-13V, MAX0, Supply Current : 30mA.

Accessories : Instruction Manual, Carrying Case, screw driver x 1 pc x 3.50 plug x 1 pc,

9V battery x 1 pc.

List of Instruments for Engineering Metrology Laboratory

Sl. No. / Name of the Items / Specification / Make / Order No
1 / Vernier Caliper (dial) / Acc: ±0.03mm. 0.01mm, 1mm/rev / Mitutoyo / 505-686
2 / Vernier Caliper (digimatic) / Acc: ±0.001” / Mitutoyo / 551-221-20
3 / Outside Micrometer(digimatic) / Acc: ±0.0001”, range: 0-1” / Mitutoyo / 293-831
4 / Tubular Inside Micrometer / 50-150 mm / Mitutoyo / 133-901
5 / Indicating Micrometer / Indicating range: ±0.060 mm / Mitutoyo / 510-121
6 / Digital Depth Gage / 0-150 mm / Mitutoyo / 571-201-20
7 / Depth Micrometer / 0 – 50 mm / Mitutoyo / 129-113
8 / Depth Base Attachment / 100 mm / Mitutoyo / 050084
9 / Universal Bevel Protractor / 12" Blade (187-103) with Clamp Box / Mitutoyo / 0187906
10 / Acute Angle Attachment / For Universal Protector / Mitutoyo / 0187105
11 / Dial Indicator (Plunger Type) / Grd:0.01mm,Range:10mm / Mitutoyo / 2046S
12 / Dial Indicator (Lever Type) / Grd:0.01mm,Range:1.6mm / Mitutoyo / 513-444T
13 / Magnetic Stand for mounting Dial Indicator / For holding stem dia:6mm, 8mm & 9.53mm / Mitutoyo / 7012-10
14 / Surface Roughness Tester / * Wide 350µm (-200µm to +150µm)
measurement range.
* Roughness parameters compatible
with ISO, DIN, ANSI, and JIS. / Mitutoyo / 178-920-2D
15 / Slip Gauges/Gauge Block / Grade:1, Range: 1.005-100mm / Mitutoyo / 516-943-11
16 / Filler Gauge / Range: 0.05-1.00mm / Insize / IS14602-100-20
17 / Pitch Gauge / Metric(600), Range:0.25-7mm / Insize / IS14820-24
18 / Pitch Gauge / Inch(550), Range: 4-42TPI / Insize / IS14821-30
19 / Fillet or Radius Gauge / Range: 7.5-15 mm / Insize / IS14802-16
20 / Sine Bar / 11’’ x 1-1/8’’ x 1-1/16’’ / Suburban / 6410045
21 / Straight Edge / 36’’/900mm, Series:385 / Starret / 0051458
22 / Surface Plate (Granite) / Size: 36x48", Grade:AA, Height: 6’’ / Mitutoyo / 517-746
23 / Surface Plate Stand / Size: 36x48" / Mitutoyo / 517-964
24 / V- Block with Clamp / Max. work piece dia:25mm, / Mitutoyo / 181-902
25 / C- Clamp / 6” Size / Bharat/JK

2) Sophisticated instrument for the Dept. of MBBT

Specifications for 96 well capillary tube Automated DNA sequencer

i.  Capillary tube: 72-96 well (with up gradation facility)

ii.  DATA collection software: yes

iii.  DATA analysis software: yes

iv.  One dedicated machine for PCR

v.  Computer with all software related to genome sequence assembly: two

vi.  Stabilizer(5KVA)

vii.  Warranty/Guarantee: Minimum two years.

viii.  Provision for extended warranty: yes.

ix.  Provision for AMC: yes

x.  Total FOB value.

xi.  Total value upto installation at Tezpur University( with demonstration)

Accessories:

i.  Chemicals/reagents for sequencing reaction: at least 1 kit

ii.  Color laser printer

iii.  Refrigerated centrifuge with a swing bucket attachment for 96 well places.

Specification for Ultracentrifuge

i.  Maximum Force : Minimum 7500000 x g

ii.  Capacity: 0.1 ml to 1200 ml

iii.  Temperature control system/Refrigeration system: Solid state thermo electric (no CFC).

iv.  Operating temperature range(ambient): 20-40 0 C

v.  Inside temperature: 0-40 0 C

vi.  Temperature increment: 10 C

vii.  User settable program: Yes

viii.  Vacuum system: No moisture shall display

ix.  LCD screen display: Essential (both RPM and RCF)

x.  Stabilizer: 5KVA

xi.  Warranty/Guarantee: Minimum two years.

xii.  Provision for extended warranty: Yes

xiii.  Total FOB value

xiv.  Total value upto installation at Tezpur University ( with demonstration).

Accessories: ( for accommodating equivalent to minimum of 1.5ml microfuge tube)

i.  Swing out rotor: of various capacities.

ii.  Fixed angle rotor: of various capacities.

3) Lab. equipment for the Department of Food Processing Technology

a) Autoclave: Microprocessor controlled fully automatic sterilizing operation Digital PID control, complete safety pressure mechanism, with water cutoff and timer.

Capacity: Min 45 lit

Temperature range: Ambient to 50 C to 124 0 C

Chamber: Stainless steel.

Gauge:-0-3 Kg/cm2, Pressure: 1.2Kg/cm2

Door packing : one touch pressure handle type

b) BOD Incubator: Temperature range 00 to 600 , Microprocessor PID multifunction controller. Capacity: Min 150 lit., silent Fan and defrost function Back light LCD display with automatic timer, SS inner chamber.

c) UV-VIS Spectrophotometer: Double beam system wave length range: 190 ~1100 nm, spectral Bandwidth: 2nm, Band accuracy: + 0.3 nm, photometric accuracy: + 0.3% T (0~ 100% T), LCD display, stability: 0.001A/h, Detector: Silicon photo diode.

d) Vacuum Packaging Machine: Stainless Steel Body, Microprocessor based, size 520x450x100 mm, sealing length : 400 mm, sealing width : 3mm; no of sealing heads: 2; Digital display, 3 Gas flushing with cycle counter.

e) Digital pH Meter: Measuring voltage: -1800 to +1800 mv; pH range:-2.00 to +20.00; Temperature: -5.0 to + 105.00C; pH resolution 0.01; pH accuracy: + 0.005

f) Shell & Tube Heat Exchanger

g) Heat Transfer Through Composite wall

h) Discharge Through Orifice & Venturimeter Test: with stainless steel tank

i)  Losses Due to Friction in Pipe Lines: with Stainless steel tanks.

j) Reynold’s Apparatus: With stainless steel tank

k) Variable Speed Rotor Mill: Microprocessor based Ergonomic control panel with membrane keyboard, Motor speed between 6000-20,000 rpm in intervals of a thousand, constant motor speed even under full load, Digital LED display of rotation, speed and motor load.

4) Consumable for the Dept. of Physics

Consumables for Scanning Electron Microscope, Model: JOEL , JSM 6390 LV :

Auto carbon coater

Suitable for specimen preparation for SEM observation operates on 110V, 50 Hz convertible 220V , 50 H3

Standard: Rotary pump

Pressure: Approx. 20 Pa or less

Evaporation Method: Resistor heating method

Over Current Protection: Built in

Carbon Rod: 5.00mm


Terms & Conditions.

1.  The rates should be quoted along with specifications and supporting documents (technical details and brochures etc.).

2.  Quotation for each department should be submitted in separate cover indicating the name of the Department.

3.  Quotations should be accompanied by-

i. A call deposit (earnest money) amounting to Rs. 5,000/- pledge in favour of

the Registrar, Tezpur University, payable at Tezpur.

4.  The rates should be exclusive of taxes and applicable tax % should be clearly indicated.

5.  The University is exempted from Custom & Excise duty.

6.  Terms and Conditions of supply should be clearly indicated in the quotations.

7.  The supplier should be in a position to deliver and install the ordered items within the stipulated time mentioned in the supply order.

8.  Items must be delivered at Napaam campus of the University at the cost of the supplier.

9.  The rates should be valid at least for a period of one year.

10.  The University reserves the right to accept or reject any or all the quotations without assigning any reason.

11.  Applications should be forwarded to the Registrar for release of call deposit against unaccepted quotations.

12.  No separate tender paper will be issued from the office; one should only download the specifications from the web site.

Sd/- Registrar