1
3D Systems, Inc. 3D Modeling
ProJet® 35x0 and ProJet® 5000 Printers Software Release Notes
ProJet® Accelerator Software
Version 5.4.4359, Part Number 305710-28
Release Date: May 9, 2014
1.0 Table of Contents
1.0 Table of Contents 2
2.0 Printers Supported 3
3.0 Highlights for this Software Release 4
ProJet® Accelerator Client 5.4.4359 4
3.1 ProJet® 5000-series control 5
3.1.1 Print3D Windows App for 5000 5
3.2 Known Issues ProJet® 3XX0 and ProJet® 5000 control 6
3.3 Known Issues ProJet® Accelerator 5.4.4359 3XX0 6
4.0 Installation Instructions 7
4.1 Installing ProJet® 3D Modeling Accelerator 7
4.2 Upgrading the ProJet® 3000, 3500 & 5000 Control Software 8
2.0 Printers Supported
· ProJet® 3D Modeling Accelerator 5.4.4359– The ProJet® 3D Modeling Accelerator is supported by computers running either Microsoft Windows XP, Windows Vista or Windows 7.0 operating Printers (both 32-Bit & 64-Bit operating Printers are supported). This software package creates and controls job submission for all Invision, ProJet® 3000-Series, 35X0-series & 5000-Series Configuration B 3D Production Printers.
· ProJet® 5000 Control 5.0.4346– This software package is installed by the ProJet® 3D Modeling Accelerator 5.4.4359. It is intended for use on the ProJet® 5000-Series Configuration B.
· ProJet® 3500 Control 5.4.4356– This software package is installed by the ProJet® 3D Modeling Accelerator 5.4.4359. It is intended for use on the ProJet® 3XXX-Series Configuration B.
3.0 Highlights for this Software Release
ProJet® Accelerator Client 5.4.4359
· ProJet® 3XX0-series control 5.4.4359– The ProJet® Accelerator 5.4.4359 allows users with the ProJet® 3000-Series Configuration B, ProJet® 3500-Series and ProJet® 3510-Series 3D Production Printers to upgrade to control version 5.4.4356.
· UHDP Mode – ProJet® 5.0.4359 ProJet 5000 introduces the new UHDP mode. The UHDP mode will only be available for the Visijet® M5-X. This mode allows users to achieve the high UHD quality while experiencing uniformed surface quality for prototypes.
· HDP Mode – ProJet® Accelerator Client 5.4.4359 ProJet 5000 offers the new HDP mode. HDP mode will only be available for Visijet® M5-X. This mode gives user the uniform surface and wall quality for their prototypes.
· ProJet® 3510-series control 5.4.4359– Will support the VNC Tight Viewer application. This will allow technicians the ability to connect to the ProJet® 3510 printers, while keeping the touch screen active on the printer.
· ProJet® 3510-series control 5.4.4359– Contains a new and improved GUI for the ProJet® 3510 printers.
· ProJet® 35XX-series control 5.4.4359 AND ProJet® 5.0.4359 ProJet® 5000 – Comprises a newly enhanced RFID reading program. This will help to stabilize RFID readings and correct most corrupt bottle tags.
3.1 ProJet® 5000-series control
· Visijet® M5-X - Introducing Visijet® M5-X prints material on the ProJet® 5000.
· VisiJet® M5 Black- Introducing Visijet® M5 Black print material on the ProJet® 5000.
· EZ Flush -The new control code will support the new EZ Flush material for the changeback from Black materials on ProJet® 35XX and ProJet® 5000 printers.
· Purge via Windows App – The new control code allows users to purge their print heads by using the Windows App. This is beneficial for recovering jets or performing the new purge procedure during changeover of materials.
3.1.1 Print3D Windows App for 5000
· Print Head Maintenance Position- Users are able to enter the printer into the “Print Head Maintenance Position” via the Print3D Windows App.
· Print Head Purge- the Print3D Windows app supports the print head purge button, which can be used for jet recovery or material changeover. Please review proper documentation before pursuing the material changeover procedure.
· Purging the Print- Before the user is allowed to purge the print head, the user must press the “Print Head Maintenance Position” button. After the print head and platform are within the “Print Head Maintenance” position, the user will be able to open the chamber down and place a pan or aluminum trey under the print head. Once the user has pressed the “Print Head Purge” button, the initial print head umbilical melt timer counts down from 300 seconds. Once the melt timer is satisfied, the print will perform one purge immediately after.
Users may install the Print3D app by going to the following link on your computer:
C:\Program Files (x86)\3D Systems\3D Modeling Accelerator\Bin
Or
C:\Program Files\3D Systems\3D Modeling Accelerator\Bin
3.2 Known Issues ProJet® 3XX0 and ProJet® 5000 control
· Servo Interrupt Error- With this software ProJet® 3000-series printers will potentially exhibit a random “Servo Interrupt Error”. This was the case in the previous ProJet® 3000-series software release. This is a top priority bug that we intend to remedy in the next release of software.
· Test Print Increment- When running consecutive “Test Prints”, the intended behavior of the system is for the printer to increment those test prints for comparison purposes. Currently the software does not behave in this manner and will just reprint the next Test Print right on top of the previous if it has not been removed from the print platform.
· Cannot Detect Tag- There is a known bug that occurs whenever a bottle is depleted. The system will notify user “Cannot Detect Tag in MDM#” if a bottle has become empty during a build.
· Build Estimator- There currently is an open issue for the build estimator. The software team is working to resolve this.
3.3 Known Issues ProJet® Accelerator 5.4.4359 3XX0
· Administrator Right to add Printer- Users are required to run ProJet® Accelerator software with full control permissions. The fix would be to right click the 3D Client Manager icon, or short cut, and select “Run As Administrator”. Users may also change the folder permissions giving the user full control access to the 3D Systems folder in the “Program Files” folder.
· For 32 bit- c:\program files(x86)\3DSystems
· For 64 bit- c:\program files\3DSystems
4.0 Installation Instructions
4.1 Installing ProJet® 3D Modeling Accelerator
Note: The 3D Modeling Accelerator replaced the 3D Modeling Client in a previous software release. While both the 3D Modeling Accelerator and 3D Modeling Client can both exist on the same Printer, it is recommended that all previous versions of the ProJet® 3D Modeling Client is uninstalled via the Add/Remove Programs window to previous possible program interference.
Installing the 3D Modeling Accelerator
1. Determine if you are running an X32 bit Windows Operating System or X64 Operating Systems.
- Right click on “My Computer” (Windows XP) or “Computer” (Windows 7 & 8)
- Choose Properties
- If it does not state X64, then the system is likely 32bit
2. Download the following Microsoft Installer (.msi):
- 3D Modeling Accelerator-5.4.4359.msi for X32 Bit
- 3D Modeling Accelerator-5.4.4359(X64).msi for 64 bit
3. Double click on the 3D Modeling Accelerator-5.4.4359.msi or 3D Modeling Accelerator-5.4.4359(X64).msi to begin the installation.
4. On the 3D Modeling Accelerator Welcome window, click the “Next” button to proceed.
5. Please thoroughly read over the License Agreement; then click “Next” to proceed.
6. Browse to choose the preferred location for installing the 3D Modeling Accelerator. Once the installation directory has been chosen, click “Next” to proceed.
7. On the Ready to install 3D Modeling Accelerator window, click “Install” to proceed with the installation.
8. Installation will begin…
9. After installation of the ProJet® 3D Modeling Accelerator, click “Finish” to close the installer.
4.2 Upgrading the ProJet® 3000, 3500 5000 Control Software
1. Open the ProJet® 3D Modeling Accelerator.
2. Connect to the ProJet® 3D Production Printer 3D Modeling Printer via the 3D Modeling Accelerator.
3. Select Modeler…Upgrade
4. In the modeler upgrade window, choose the available Modeler Upgrade Version and click the Upgrade button.
Note: Modeler Upgrade version for 35X0-series control software is 5.4.4356.
Modeler Upgrade version for 3000-series, Configuration A control software is 2.05.2395.
Modeler Upgrade version for 3000-series, Configuration B control software is 5.4.4356.
Modeler Upgrade version for 5000-series control software is 4.0.3039.
Modeler Upgrade version for InVision control software is 3.44
The correct version will be displayed depending on the machine type your ProJet Accelerator Client is currently accessing.
5. Congratulations! This ProJet® Software installation is complete!