VISHAY SAP
THIN FILM PART (USA) NUMBERING RULES.
Contents
MODEL / PAGEMP or MPT(Document number 60092) (Comm Code 8533210020) / 4
MP or MPT Custom (Comm Code 8533210020) / 5
MPM or MPMT(Document number 60001)(Comm Code 8533210020) / 6
MPM or MPMT Custom (Comm Code 8533210020) / 7
MPD or MPDT(Document number 60001)(Comm Code 8533210020) / 8
MPD or MPDT Custom (Comm Code 8533210020) / 9
MPDA or MPDAT(Document number 60016)(Comm Code 8533210020) / 10
ORN or ORNT(Document number 60005)(Comm Code 8533210010) / 11
ORN or ORNT Custom (Comm Code 8533210010) / 12
ORN Divider(Document number 60006)(Comm Code 8533210010) / 13
OSOP or OSOPT(Document number 60002)(Comm Code 8533210010) / 14
OSOP or OSOPT Custom (Comm Code 8533210010) / 15
VSOR(Document number 60003)(Comm Code 8533210010) / 16
VSSR(Document number 60003)(Comm Code 8533210010) / 17
VTSR(Document number 60003)(Comm Code 8533210010) / 18
NOMC or NOMCT(Document number 60007)(Comm Code 8533210010) / 19
NOMC or NOMCT Custom (Comm Code 8533210010) / 20
TOMC or TOMCT(Document number 60008)(Comm Code 8533210010) / 21
TOMC or TOMCT Custom (Comm Code 8533210010) / 22
WOMC or WOMCT Custom(Document number 60010) / 23
CSO ,CSOT or CSOG Custom(Document number 60011)(Comm Code 8533210010) / 24
VSOR2000S1(Document number 60010)(Comm Code 8533210010) / 25
TLCC or LCC(Document number 60012)(Comm Code 8533210020) / 26
JLCC CUSTOM (Comm Code 8533210020) / 27
LCC or LCCT CUSTOM (Comm Code 8533210020) / 28
87012 (Comm Code 8533210010) / 29
87014 (Comm Code 8533210020) / 30
87015(Comm Code 8533210020) / 31
MODEL (cont’d) / PAGE (cont’d
87016 (Comm Code 8533210020)
87017 (Comm Code 8533210020)
Zero Ohm DSCC Jumpers / 32
33
34
04008 (Comm Code 8533210030) / 35
04009 (Comm Code 8533210030) / 36
94012 (Comm Code 8533210030)
94013 (Comm Code 8533210030) / 37
38
94014 (Comm Code 8533210030)
94015 (Comm Code 8533210030) / 39
40
94016 (Comm Code 8533210030)
94017 (Comm Code 8533210030) / 41
42
94018 (Comm Code 8533210030)
94019 (Comm Code 8533210030)
94025 (Comm Code 8533210030) / 43
44
45
94026(Comm Code 8533210030) / 46
MPH or MPHT(Document number 53039)(Comm Code 8533210020)
MPH or MPHT Custom(Comm Code 8533210020) / 47
48
PR(Document number 60003)(Comm Code 8533210020) / 49
PR Custom(Comm Code 8533210020) / 50
M55342 or D55342(Document number 60018)(Comm Code 8533210030) / 51
P(Document number 60023)(Comm Code 8533210030) / 52
FC(Document number 60093)(Comm Code 8533210030) / 53
PTN(Document number 60026)(Comm Code 8533210030) / 54
L(Document number 60027)(Comm Code 8533210030) / 55
LR (Comm Code 8533210030) / 56
T(Document number 60031)(Comm Code 8533210030) / 57
M or T(Document number 60003)(Comm Code 8533210030) / 58
M,L,T,M,P-, PTN-, PLT- and PNM-Custom (Comm Code 8533210030) / 59
TSP ,TSPS, and TSPL(Document number 60037)(Comm Code 8533210050) / 60
TSP,TSPS, and TSPL Custom(Document number 60036) (Comm Code 8533210050) / 61
VTF Standard & Custom(Document number 60038 and 60041)(Comm Code 8533210050) / 62
ECSP Sip Custom (Comm Code 8533210050) / 63
ECDP DIP Custom (Comm Code 8533210060) / 64
100-267 or 100-267S(Document number 60044)(Comm Code 8533210050) / 65
CS or CSD(Document number 60081 and 60046)(Comm Code 8533210050 and 8533210060 CSD) / 66
HD(Document number 60046) (Comm Code 8533210060) / 67
TO PK Custom / 68
HVPSx or HVPSxS(Document number 60091)(Comm Code 8533210000) / 69
TDP or TDPT(Document number 60045) (Comm Code 8533210060) / 70
TDP or TDPT Custom(Comm Code 8533210060) / 71
VR(Document number 60088) (Comm Code 8533210020) / 72
VTSRC(Document number 60084, 60085, 60083, and 60086) (Comm Code 8533210010) / 73
VSSRC(Document number 60084, 60085, 60083, and 60086) (Comm Code 8533210010) / 74
VSORC(Document number 60084, 60085, 60083, and 60086) (Comm Code 8533210010) / 75
VSSRC1284(Document number 60077) (Comm Code 8533210010) / 76
FP200, FP201, or FP202(Document number 61073) (Comm Code 8533210020) / 77
FLPK Custom (Comm Code 8533210020) / 78
VSSR, VTSR, VSOR Custom(Comm Code 8533210010) / 79
Quick-Net / 80
Lot Charges / 81
SJM(Comm Code 8533210030) / 82
MEDM(Comm Code 8533210030) / 83
L-206-135(Comm Code 8533210030) / 84
TSP105-344 (Comm Code 8533210050) / 85
PLT (Document number 60030)(Comm Code 8533210030) / 86
PNM (Document number 60057)(Comm Code 8533210030) / 87
DFN (Document number 60109) (Comm Code 8533210010) / 88
DFN Divider (Document number 60110) (Comm Code 8533210010) / 89
DFN Custom (Comm Code 8533210010) / 90
QFN- Custom (Document 60015) (Comm Code 8533210010) / 91
PAT (Document 60024) (Comm Code 8533210030) / 92
MPMA (60013) ---- NOT YET RELEASED / 93
PHP (Document 60076) / 94
PLTT (Document 60082) / 95
ORNV (Document 60012) / 96
Model MP or MPT (Document number 60092)
SAP Part Number SAP Description
MP31002AWS MP3 5K 5K 0.1%abs 0.05%ratio WS
MPT41003BT1 MPT4 50K 50K 0.1%abs 0.1%ratio T1 e3
Model
/LEADS
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
2 or 3 DIGITS /1 DIGIT
/4 DIGITS
/1 DIGIT
/ 2 DIGITMP
Tin /LeadMPT
Lead Free ( e3) / 3
4 / First 3 digits are significant figures and the last digit specifies the number of zeros to follow. When like values are required use total resistance.
Example
1002 = 10K ( 5K/5K)
1003 = 100K ( 50K/50K) / Abs Tol. Ratio
A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5% / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T1 = 1000 Min 1000 Mult
MODEL MP or MPT CUSTOM
SAP Part NumberSAP Description
MP1xx-xxxWSMP Custom 1xx-xxx WS
MPT1xx-xxx-xT1MPT Custom 1xx-xxx-x T1 e3
Model
/Custom part number
/Packaging
3 or 4 DIGITS /7 or 9 DIGITS
/ 2 DIGITSMP
Tin Lead
MPT
Lead Free (e3) / 1xx-xxx
1xx-xxx-x / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T1 = 1000 Min 1000 Mult
Model MPM or MPMT (Document number 60001)
SAP Part Number SAP Description
MPM1002AWS MPM 5K 5K 0.1%abs 0.05%ratio WS
MPMT1003AT1 MPMT 50K 50K 0.1%abs 0.05%ratio T1 e3
MPMT25012501QT1 MPMT 2.5K 2.5K 0.05%abs 0.01%ratio T1 e3
Model
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
3 or 4 DIGITS /4 or 8 DIGITS
/1 DIGIT
/ 2 DIGITSMPM
Tin /LeadMPMT
Lead Free (e3) / First 3 digits are significant figures and the last digit specifies the number of zeros to follow. When like values are required use total resistance. When dual values are required list both values.
Example
1002 = 10K ( 5K/5K)
1003 = 100K ( 50K/50K)
10011002 = 1K/10K divider / Abs Tol. Ratio
A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5%
*Z =0.1% 0.025%
*Q =0.05% 0.01%
*Tol. Available 1K and up / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 4000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
MODEL MPM or MPMT CUSTOM
SAP Part NumberSAP Description
MPM1xx-xxxWSMPM Custom 1xx-xxx WS
MPMT1xx-xxx-xT1MPMT Custom 1xx-xxx-x T1 e3
Model
/Custom part number
/Packaging
3 or 4 DIGITS /7 or 9 DIGITS
/ 2 DIGITSMPM
Tin Lead
MPMT
Lead Free (e3) / 1xx-xxx
1xx-xxx-x / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 4000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
Model MPD or MPDT(Document number 60016)
SAP Part NumberSAP Description
MPD1002AWSMPD 5K 5K 0.1%abs 0.05%ratio WS
MPDT1003AT1MPDT 50K 50K 0.1%abs 0.05%ratio T1 e3
MPDT10011003BT1MPDT 1K 100K 0.1%abs 0.1%ratio T1 e3
Model
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
3 or 4 DIGITS /4 or 8 DIGITS
/1 DIGIT
/ 2 DIGITSMPD
Two resistorTin /Lead
MPDT
Two resistor
Lead Free (e3) / First 3 digits are significant figures and the last digit specifies the number of zeros to follow. When like values are required use total resístance. When dual values are required list both values
Example
1002 = 10K ( 5K/5K)
1003 = 100K ( 50K/50K)
10011002 = 1K/10K divider / Abs Tol. Ratio
A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5% / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T1 = 1000 Min 1000 Mult
MODEL MPD or MPDT CUSTOM
SAP Part NumberSAP Description
MPD1xx-xxxWSMPD Custom 1xx-xxx WS
MPDT1xx-xxx-xT1MPDT Custom 1xx-xxx-x T1 e3
Model
/Custom part number
/Packaging
3 or 4 DIGITS /7 or 9 DIGITS
/ 2 DIGITMPD
Tin Lead
MPDT
Lead Free (e3) / 1xx-xxx
1xx-xxx-x / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T1 = 1000 Min 1000 Mult
Model MPDA or MPDAT(Document number 60016)
SAP Part NumberSAP Description
MPDAT3002AWSMPDAT 30K 0.1%abs 0.05%ratio WS e3
Model
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
4 or 5 DIGITS /4 DIGITS
/1 DIGIT
/ 2 DIGITSMPDA
Three equal series resistorsTin /Lead
MPDAT
Three equal series resistors
Lead Free ( e3) / First 3 digits are significant figures and the last digit specifies the number of zeros to follow. When like values are required use total resistance.
Example
3002 = Three 10K ohm resistors / Abs Tol. Ratio
A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5% / BS = BULK 100 Min 1 Mult
WS = WAFFLE 100 Min 1 Mult
WI = 100 Min/ 1Mult (item single lot date code)
WP = 100 Min/ 1Mult (Package unit single lot date code)
TAPE AND REEL
T1 = 1000 Min 1000 Mult
Model ORN or ORNT (Document number 60005)
SAP Part Number SAP Description
ORNA1002AUF ORNA 10K 0.1%abs 0.05%ratio UF
ORNTA1003ZTS ORNTA 100K 0.1%abs 0.025%ratio TS e3
Model
/Schematic
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
3 or 4 DIGITS /1 DIGIT
/4 DIGITS
/1 DIGIT
/ 2 DIGITSORN
Tin /LeadORNT
Lead free ( e3) / A = 4 isolated equal resistors / First 3 digits are significant figures and the last digit specifies the number of zeros to follow.
Example
1002 = 10K
1003 = 100K
4991 = 4.99K / Abs Tol. Ratio
A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5%
*Q=0.05% 0.01%
*Z = 0.1% 0.025%
*Tol. Available 500 Ohm and up / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 3000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date code)
MODEL ORN or ORNT CUSTOM
SAP Part NumberSAP Description
ORN1xx-xxxUFORN Custom 1xx-xxx UF
ORNT1xx-xxx-xT1ORNT Custom 1xx-xxx-x T1 e3
Model
/Custom part number
/Packaging
3 or 4 DIGITS /7 or 9 DIGITS
/ 2 DIGITSORN
Tin lead
ORNT
Lead free (e3) / 1xx-xxx
or
1xx-xxx-x
or
1xx-xxx-xxxx / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 3000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date code)
Model ORNA or ORNTA Divider (Document number 60006)
SAP Part NumberSAP Description
ORNA5-1UFORNA 10K 2K 0.1%abs 0.05%ratio UF
ORNTA100-1UFORNTA 100K 1K 0.1%abs 0.05%ratio UF e3
Model
/Divider Ratio
/Packaging
4 or 5 DIGITS /3, 4 or 5 DIGITS
/ 2 DIGITSORNA
Tin /LeadORNTA
Lead free ( e3) / 2-1 = 10K, 5K5-1 = 10K, 2K
10-1 = 10K,1K
20-1 = 20K, 1K
25-1 = 25K,1K
50-1 = 50K,1K
100-1 = 100K,1K / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 3000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date
Model OSOP or OSOPT (Document number 60002)
SAP Part NumberSAP Description
OSOPA1002BUFOSOPA 10K 0.1%abs 0.1%ratio UF
OSOPTA1003AT1OSOPTA 100K 0.1%abs 0.05%ratio T1 e3
Model
/Schematic
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
4 or 5 DIGITS /1 DIGIT
/4 DIGITS
/1 DIGIT
/ 2 DIGITSOSOP
Tin LeadOSOPT
Lead Free (e3) / A = 10 nominally equal resistors with each resistor isolated from all others and wired directly across / First 3 digits are significant figures and the last digit specifies the number of zeros to follow.
Example
1002 = 10K
1003 = 100K / Abs Tol. Ratio
*A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5%
*Tol. Available 500 ohm and up / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 2500
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date
MODEL OSOP or OSOPT CUSTOM
SAP Part Number SAP Description
OSOP1xx-xxxUFOSOP Custom 1xx-xxx UF
OSOPT1xx-xxx-xT1OSOPT Custom 1xx-xxx-x T1 e3
Model
/Custom part number
/Packaging
4 or 5 DIGITS /7 or 9 DIGITS
/ 2 DIGITSOSOP
Tin lead
OSOPT
Lead free (e3) / 1xx-xxx
or
1xx-xxx-x / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 2500
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date
Model VSOR (Document number 60003)
SAP Part NumberSAP Description
VSOR1601103JTFVSOR 16pin Bussed 10K 5% TF e3
VSOR160343R2FUFVSOR 16pin Isolated 43.2 1% UF e3
VSOR1605331471GTFVSOR 16pin Dual Term 330 470 2% TF e3
Model
/Pin Count
/Schematic
/Resistance
/Tolerance
/Packaging
4 DIGITS /2 DIGITS
/2 DIGITS
/3, 4 or 6 DIGITS
/1 DIGIT
/ 2 DIGITSVSOR
Lead free ( e3) date code > 2705 / 16 / 01 (Bussed)03 (Isolated) / XXX= 100R & all 1% , 2%, & 5%
First 2 digits are significant figures. Last digit specifies number of zeroes to follow
XXXX = <100R 1%
First 3 digits are significant figures. Last digit specifies number of zeroes to follow. / F = 1%
G = 2%
J = 5% / TAPE AND REEL
TF = Full Reel 2500
UF = TUBED
05 (Dual Term)
47 (Diff Term) / xxx xxx
First 2 digits are significant figures. Last digit specifies number of zeroes. / G = 2%
J = 5%
Model VSSR (Document number 60003)
SAP Part NumberSAP Description
VSSR1601103JTFVSSR 16pin Bussed 10K 5% TF e3
VSSR160343R2FUFVSSR 16pin Isolated 43.2 1% UF e3
VSSR2005331471GTFVSSR 20pin Dual Term 330 470 2% TF e3
Model
/Pin Count
/Schematic
/Resistance
/Tolerance
/Packaging
4 DIGITS /2 DIGITS
/2 DIGITS
/3, 4 or 6 DIGITS
/1 DIGIT
/ 2 DIGITSVSSR
Lead free ( e3) date code > 2705 / 1620
24 / 01 (Bussed)
03 (isolated) / XXX= 100R & all 1%, 2% & 5%
First 2 digits are significant figures. Last digit specifies number of zeroes to follow
XXXX=<100R 1%
First 3 digits are significant figures. Last digit specifies number of zeroes to follow. / F = 1%
G = 2%
J = 5% / TAPE AND REEL
TF = Full Reel 2500
UF = TUBED
16
20 / 05 (Dual Term)
47 (Diff Term) / XXX XXX
First 2 digits are significant figures. Last digit specifies number of zeroes. / G = 2%
J = 5%
Model VTSR (Document number 60003)
SAP Part NumberSAP Description
VTSR1601103JTFVTSR 16pin Bussed 10K 5% TF e3
VTSR160343R2FUFVTSR 16pin Isolated 43.2 1% UF e3
VTSR2005331471GTFVTSR 20pin Dual Term 330 470 2% TF e3
VTSR2047331221JTFVTSR 20pin Diff Term 330 220 5% TF e3
Model
/Pin Count
/Schematic
/Resistance
/Tolerance
/Packaging
4 DIGITS /2 DIGITS
/2 DIGITS
/3, 4 or 6 DIGITS
/1 DIGITS
/ 2 DIGITSVTSR
Lead free ( e3) date code > 2705 / 1620
24 / 01 (Bussed)
03 (Isolated) / XXX= 100R & all 1%, 2% & 5%
First 2 digits are significant figures. Last digit specifies number of zeroes to follow
XXXX= <100R 1%
First 3 digits are significant figures. Last digit specifies number of zeroes to follow. / F = 1%
G = 2%
J = 5% / TAPE AND REEL
TF = Full Reel 2500
UF = TUBED
16
20 / 05 (Dual Term)
47 (Diff Term) / XXX XXX
First 2 digits are significant figures. Last digit specifies number of zeroes. / G = 2%
J = 5%
Model NOMC or NOMCT (Document number 60007)
SAP Part NumberSAP Description
NOMC16031002BUFNOMC 16pin 10K 0.1%abs 0.1%ratio UF
NOMCT14031003ZT1NOMCT 14pin 100K 0.1%abs 0.025%rat T1 e3
NOMC16011002BUFNOMC 16pin 10K 0.1%abs 0.1%ratio UF
NOMCT14012002ZT1NOMCT 14pin 20K 0.1%abs 0.025%rat T1 e3
Model
/Pins
/Schematic
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
4 or 5 DIGITS /2 DIGITS
/2 DIGITS
/4 DIGITS
/1 DIGIT
/ 2 DIGITSNOMC
Tin LeadNOMCT
Lead Free (e3) / 14
16 / 03 = 7 or 8 Isolated equal value resistors
01= 13 or 15 bussed equal resistors (available in 10k and 20k only as a standard part) / First 3 digits are significant figures and the last digit specifies the number of zeros to follow.
Example
1002 = 10K
1003 = 100K / Abs Tol. Ratio
*A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5%
*Z= 0.1% 0.025%
*Tol. Available 1K and up / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 2500
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date
MODEL NOMC or NOMCT CUSTOM
SAP Part NumberSAP Description
NOMC1xx-xxxT1NOMC Custom 1xx-xxx T1
NOMCT1xx-xxx-xUFNOMCT Custom 1xx-xxx-x UF e3
Model
/Custom part number
/Packaging
4 or 5 DIGITS /7 or 9 DIGITS
/ 2 DIGITSNOMC
Tin lead
NOMCT
Lead Free (e3) / 1xx-xxx
or
1xx-xxx-x / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 2500
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date
Model TOMC or TOMCT (Document number 60008)
SAP Part NumberSAP Description
TOMC16031002BUFTOMC 16p Iso 10K 0.1%abs 0.1%rat UF
TOMCT16011003ZT1TOMCT 16p bus 100K 0.1%abs 0.025%ratT1e3
Model
/Pins
/Schematic
/Resistance
/Tolerance and Ratio Tolerance
/Packaging
4 or 5 DIGITS /2 DIGITS
/2 DIGITS
/4 DIGITS
/1 DIGIT
/ 2 DIGITSTOMC
Tin LeadTOMCT
Lead Free (e3) / 16 / 01 = 15 bussed equal resistors
03 = 8 Isolated equal value resistors / First 3 digits are significant figures and the last digit specifies the number of zeros to follow.
Example
1002 = 10K
1003 = 100K / Abs Tol. Ratio
**A = 0.1% 0.05%
B = 0.1% 0.1%
C = 0.25% 0.1%
D = 0.5% 0.1%
F = 1% 0.5%
*Z= 0.1% 0.025%
*Tol. Available 1K and up
** Tol available 250 and up / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 2000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date
MODEL TOMC or TOMCT CUSTOM
SAP Part NumberSAP Description
TOMC1xx-xxxT1TOMC Custom 1xx-xxx T1
TOMCT1xx-xxx-xUFTOMCT Custom 1xx-xxx-x UF e3
Model
/Custom part number
/Packaging
4 or 5 DIGITS /7 or 9 DIGITS
/ 2 DIGITSTOMC
Tin Lead
TOMCT
Lead free (e3) / 1xx-xxx
or
1xx-xxx-x / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 2000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date)
Model WOMC or WOMCT CUSTOM (Document number 60010)
SAP Part NumberSAP Description
WOMC1xx-xxxT1WOMC Custom 1xx-xxx T1
WOMCT1xx-xxx-xT1WOMCT Custom 1xx-xxx-x T1 e3
Model
/Custom part number
/Packaging
4 or 5 DIGITS /7 or 9 DIGITS
/ 2 DIGITSWOMC
Tin lead
WOMCT
Lead Free (e3) / 1xx-xxx
or
1xx-xxx-x / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel 1000
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date)
Model CSO or CSOT CUSTOM (Document number 60011)
SAP Part NumberSAP Description
CSO1xx-xxxT1CSO Custom 1xx-xxx T1
CSOT1xx-xxx-xT1CSOT Custom 1xx-xxx-x T1 e1
CSOG1xx-xxx-xT1CSOG Custom 1xx-xxx-x T1 e4
Model
/Custom part number
/Packaging
3 or 4 DIGITS /7 or 9 DIGITS
/ 2 DIGITSCSO
Tin lead
CSOT
Lead free (e1)
CSOG
Lead free (e4) / 1xx-xxx
or
1xx-xxx-x / TAPE AND REEL
T0 = 100 Min 100 Mult
T1 = 1000 Min 1000 Mult
T3 = 300 Min 300 Mult
T5 = 500 Min 500 Mult
TF = Full Reel
TS = 100 Min 1 Mult
TI = 100 Min/ 1Mult (item single lot date code)
TP = 100 Min/ 1Mult (Package unit single lot date code)
UF = TUBED
UI = 100 Min/ 1Mult (item single lot date code)
UP = 100 Min/ 1Mult (Package unit single lot date)
Model VSOR2000S1 (Document number 60009)
SAP Part NumberSAP Description
VSOR2000S1TFVSOR2000S1 V35 port terminator TF e3
Model
/Packaging
10 DIGITS / 2 DIGITSVSOR2000S1
/ TAPE AND REELTF = Full Reel 2500
UF = TUBED
Model TLCC or LCC or TLCCT or LCCT(Document number 60012)
SAP Part NumberSAP Description
TLCC20AE1002BUFTLCC 20 Iso 25ppm 10K 0.1% UF
LCC16AE1002BUFLCC 16 Iso 25ppm 10K 0.1% UF
TLCCT16A01K1003KUFTLCCT 16 Bus 100ppm 100K 10% UF e1
TLCCT20A06K1003KUFTLCCT 20 Iso Adj 100ppm 100K 10% UF e1
TLCCT20A03K1003KUFTLCCT 20 Iso Par 100ppm 100K 10% UF e1
Model
/Terminal Count
/Schematics
/TCR Characteristics
/Resistance
/Tolerance
/Packaging
4 or 5 DIGITS /2 DIGITS
/1 or 3 DIGITS
/1 DIGIT