UTK Displacer Level Controller

Summary

Measuring element of UTK displacer level controllerisball float or displacer,measuring element is connected with magnet tube. When level raised, magnet tube moves up and enters external magnetic field. Through magnet induction effect or magnet coupling effect, the magnet controlling switch or offset magnet steel is pulled and makes switch contact on or off. When level goes down, the magnet tube moves down and goes out off the external magnet field. Then the magnetic controlling switch backs to the original state or the offset magnet steel goes down back to new balance position under the action of self-weight, then makes switch contact on or off. In this way, it realizes level controlling and alarming.

Main technical parameter

Nominal pressure: ≤16.0MPa;

Measuring accuracy: level controlling: ±4mm;

interface controlling: ±6mm;

Flange standard: HG/T20592-2009,

HG/T20615-2009 or on request

Ambient temperature: -40℃~+80℃

Operatingtemperature: -40℃~150℃

(high temperature type: 300℃)

Medium density: level controller: ρ≥0.5g/cm3

interface controller: ρ1 - ρ2≥0.25g/cm3

Medium viscosity: ≤1St(10-4m2/s)

Wetted material: 20, 304, 316L or on request

Power supply inlet: G1/2″(female thread)

oronrequest

Explosion-proof: ExdⅡCT4-T6,

ExiaⅡCT4-T6

Protection class: IP67

Relative equipment: safety barrier (see safety barrier recommendation sheet)

Contact capacity:

Switch type / Max.
voltage AC / Max.
current (A) / Contact point
number / Contact
resistance
(≯Ω) / Switching speed (≯ms) / Service life
(≮ 104times)
Reed switch / 250V / 1 / SPDT / 0.03 / 3 / 50
Microswitch / 250V / 5 / SPDT / 0.03 / 3 / 50

Note: 24V DC is only for intrinsically safe.

UTK Displacer Level Controller

Controlling range:

For level controlling

Model / Measuring
element / Controlling
position / Max.pressure
MPa / Nominal diameter / Alarming setting-point
B(mm) / Range
H(mm) / Remark
UTK100 / Ball float / Upper
Or lower limit / 6.3 / DN40 / On request / Controlling position non-adjustable
UTK300 / Displacer / Upper
Or lower limit / 4.0 / DN80 / On request / Controlling
position is adjustable;
The rang of upper limit and
low limit are adjustable.
Upper and lower limits / On request
UTK400 / Displacer / Upper
Or lower limit / 16.0 / DN40 / On request / Controlling position non-adjustable

For interface controlling:

Model / Controlling
position / Max.pressure
MPa / Min.density / Min.density
difference / Alarming setting-point
B(mm)
g/cm3
Ball-float / Upper or lower limit / 4.0 / 0.5 / 0.25 / On request

UTK Displacer Level Controller

Model selection table

UTK-100

Model / Code / Code meaning
UTK- / Displacer level controller
100 / Flange sealing
A / Normal type
B / Side-bottom mounted
C / Side-side mounted Ⅰ
D / Side-side mounted Ⅱ
1 / Reed switch
3 / Microswitch
X / Upper limit or low limit
* / Medium density(g/cm³)
-
* / Alarm setting-point
(distance to upper interface flange mm)
i / Intrinsically safe
d / Explosion isolating
UTK- □ □ □ □ □ - □ □

Example: UTK-100D3X0.8-178i is flange sealing, side-side mountedⅡtype, microswitch,upper or low limit alarm, medium density is 0.8g/cm³, alarm setting-point is 178mm, intrinsically safe displacer level controller.

UTK-300, UTK-400

Model / Code / Code meaning
UTK- / Displacer level controller
300 / Top mounted
400 / High pressure type (side-side mounted)
1 / Reed switch
3 / Microswitch
X / Upper or lower limit
Y / Upper and lower limit(only for UTK300)
* / Medium density(g/cm³)
-
* / Alarm setting-point
(distance to upper interface flange mm)
i / Intrinsically safe
d / Explosion isolating
UTK- □ □ □ □ - □ □

Example: UTK-4003X0.8-178i is high pressure type, microswitch, upper or lower limit alarm, medium density is 0.8g/cm³, alarm setting-point is 178mm,intrinsically safe displacer level controller.

UTK Displacer Level Controller

Outline and installation dimensions

  1. Structure

Safety barrier recommendation sheet

Dandong Top Electronics Instrument Co., Ltd / TP5041-Ex, TP5045-Ex
Shanghai Automation Instrument Institute / CS8041-Ex, CS8045-Ex

Order requirements

1

WWW.DDTOP.COM

Operating medium

Operating pressure

Operating temperature

Flange standard

Wetted material

Medium density

Alarm setting-point

Other special requirement

1

WWW.DDTOP.COM