HASP Update Guide

Revise History

Date / Version / Description
2011-02-15 / 1.0 / Mo Zhonghua
Date Last Modified

Content

1Installation Package

1.1Installation Environment

1.2HASP Driver Installation

1.3Components Description

2Firmware Update User Guide

3HASP Client Description

3.1Upgrade Procedures

3.1.1Terms

3.1.2Auto Upgrade Procedures

3.1.3Manually Upgrade

3.2HASP Upgrade Client Interface

3.3HASP Upgrade Server IP Address Configuration

3.4Dongle upgrade operation.

3.4.1Auto Upgrade Operation Guide

3.4.2Collect C2V File

3.4.3Upgrade with V2C File

1Installation Package

1.1Installation Environment

This upgrade client is based on NetFramework2.0; please install Net Framework 2.0 before you start.

IfNet Framework 2.0 is not installed in the system yet, a window as below will pop up.

1.2HASP Driver Installation<0}.

{After Net Framework installation is complete, it will install HASP driverautomatically.If you have already installed it in your computer, please click Cancel as shown below. .

1.3Components Description<0}.

The shortcutwill be established in Start Program after the installation is complete.<0}.

  1. Firmware Update: Update the dongle Firmware from version 2.16 to version 3.21.
  2. DingLi SRM upgrade client: main program, finish the upgrade operation.
  3. Uninstall DingLi SRM upgrade client.
  4. HASP Driver Installation.
  5. Manual.

2Firmware Update User Guide<0}.

Notice: Please upgrade the Firmware to Version 3.21 before proceeding with other operation.

{Notice: If you are not sure if the Firmware version has been upgraded to version 3.21, please renew the upgrade once more.

The operating procedure is as below:

  1. Insert the dongle into PC.
  2. Open firmware update shortcut.
  3. Click Apply Update button.

3HASP Client Description<0}.

3.1Upgrade Procedures.

There are two methods for upgrade:

  1. Manually Upgrade
  2. Automatic Upgrade

Notice: If you could not visit the server or the auto upgrade is failed, you may upgrade manually

3.1.1Terms

  • C2V file: it contains the current dongle information which was collected by customer.
  • V2C file: it contains the current dongle upgrade information which was generated by C2V file.
  • Upgrade by v2c file: the user can write the upgrade information in the dongle with the client after the administrator generated the V2C file。

3.1.2Auto Upgrade Procedures.

Please follow the procedures below to upgrade

  1. Connect to the upgrade server by the client.
  2. Insert dongle into PC.
  3. Click Auto Upgrade to finish the upgrade

Notice: It will take about 2-3 minutes to finish the upgrade; the software maybe in a halted state during the process, please wait patiently. If the upgrade failed, you may try it once again.

3.1.3Manually Upgrade

{Please follow the procedures below to upgrade:

  1. Insert the dongle in PC, collect C2V file with the client.
  2. Send the C2V File to the administrator ().
  3. Theadministrator will generate V2Cfile, it contains the current dongle upgrade information which was generated by C2V file.
  4. Send the C2V File to the administrator (). via E-mail.
  5. Write the V2C file information in the dongle to finish the dongle upgrade.

Notice: It is not required to connectto theupgrade server formanually upgrade, the user and administrator can send files directly via E-mail.

3.2HASP Upgrade Client Interface

Notice: Please insert the dongle to PC when you start HASP client, or else the notice below will pop up:

The client contains 3 regions as below :<0}.

  1. Server configuration: please enter server IP address and port and then connect.
  2. Upgrade Operation: finish the dongle upgrade.

a)Auto upgrade: connect to the server first and then insert the dongle into PC.

b)Insert the dongle into PC, collect C2V file with the client.

c)Upgrade with V2C file: write the V2C file information in the dongle.

  1. Message box: the operation result will pop up.

3.3HASP Upgrade Server IP Address Configuration<0}.

It is required to fill in the server IP address and port, the current server address is : 61.143.60.84 Port: 8080

Connect button: connect to the specified server.

Disconnect button: disconnect the current connection.

Notice: Please connect to the server before auto upgrade, for manually upgrade, it is not required to connect to the server.

3.4Dongle upgrade operation.

AutoUpgradeis used to finish the auto upgrade, extract C2V file and use V2C file to upgrade to finish manually upgrade.

Notice: Only one dongle can be connected to PC at one time, if you need to upgrade many dongles, please upgrade them one by one.

3.4.1Auto Upgrade Operation Guide

Please connect to the server first, and then insert the dongle into PC, press Auto Upgrade when the connection is successful. The information below will be displayed after successful upgrade.

Notice: the dongle needs to be formatted if it is upgraded for the first time, the System will finish the formatting automatically, please don’t plug out the dongle before the upgrade is finished.

3.4.2ExtractC2V File

It is not required to connect to the server, please insert the dongle into PC, the client will collect the required information and save it as C2V file. Please send the C2V file to the administrator.

3.4.3Upgrade with V2C File

The administrator will generate the V2C file with C2V file and send it back to the client, the user need to write the V2C file in the dongle, and then complete the operation by clicking Upgrade with V2C file..

1