Fire Department 2018 Pumper/Rescue RFP

Specifications Statement "E"

Standard equipment must include the following:

Item / Equipment / Details / Yes / No / Details
1 / Pump and governor / 6000 litres / 1750 USG per minute minimum. Class 1 Governor Control to standardize Fire Department fleet. / ☐ / ☐ / Click or tap here to enter text. /
2 / Tank / 1892 litres (500 USG) litres minimum / ☐ / ☐ / Click or tap here to enter text. /
3 / Light Tower / Command Light or equivalent. 12 volt powered. Minimum 4 heads / ☐ / ☐ / Click or tap here to enter text. /
4 / 8 person cab with minimum 5 SCBA seats that include inertia release brackets. Cab will have front and back heat and air conditioning controls that work independently of each other. / Will consider the use of maximum 2 jump seats. Cab will be air conditioned / heated. A secure Storage area and Map box will be provided. Cab will have vinyl flooring and will be designed and insulated to limit exterior noise penetration.
Driver and Officer seats shall be adjustable air ride seats.
Cab should be designed to provide as much headroom as possible while meeting height requirements. / ☐ / ☐ / Click or tap here to enter text. /
5 / Command function / Include a retractable table to function as a command post with a seating layout that will make for ergonomic use of the passenger area for command operations. 4 auxillary 12 V sockets and 4 USB connections will be provided. Two for command functional area and 2 for Officers position. / ☐ / ☐ / Click or tap here to enter text. /
6 / Foam system, approximately 100 litre/ 25 USG tank / Plumbed to crosslays, bumper trashline and rear 65 mm discharge / ☐ / ☐ / Click or tap here to enter text. /
7 / Crosslays - 2 trays of 60 meters, 45mm hose / Preference will be given to low placement with removable trays for ease of deployment and reloading. / ☐ / ☐ / Click or tap here to enter text. /
8 / Extrication compartment / One curbside compartment shall be designed to accommodate the current extrication equipment utilized by the Fire Department. / ☐ / ☐ / Click or tap here to enter text. /
9 / Absorb All Hopper / A hopper with a proven design to provide easy access to utilize absorb all without climbing onto the apparatus. Filling of hopper can be done from top of apparatus. / ☐ / ☐ / Click or tap here to enter text. /
10 / SCBA cylinders / The body design shall maximize unutilized space for the storage of SCBA cylinders. / ☐ / ☐ / Click or tap here to enter text. /
11 / Extended Front Bumper/Hose well / Extended front bumper shall be stainless steel/aluminum Plumbed and designed for the placement of 45 meters, 45 mm hose. Drain valve at bumper.
Hose well shall have a weather proof lid and will be self draining. / ☐ / ☐ / Click or tap here to enter text. /
12 / Through Tank Ladder and pike pole Storage / NFPA complaint ladder complement for a Pumping Apparatus. / ☐ / ☐ / Click or tap here to enter text. /
13 / Solid aluminum hose bed cover / ☐ / ☐ / Click or tap here to enter text. /
14 / Discharges / Two curbside 65 mm discharges. One drivers side 65 mm discharge. One rear 65 mm discharge. One curbside large diameter discharge with a 100mm Storz connection / ☐ / ☐ / Click or tap here to enter text. /
15 / Ontario compliant hose connections / ☐ / ☐ / Click or tap here to enter text. /
16 / Stokes basket storage / Bidder to determine placement of stokes to maximize space utilization and ergonomics of access. / ☐ / ☐ / Click or tap here to enter text. /
17 / Trays and shelves to accommodate Fire Department equipment. Fire Department will be supplying all hand equipment other than the ladder compliment noted in section 12. / Bidder will provide detailed explanation and design of placement of equipment identified from the Fire Department visit with the bid. This will include placement of all equipment, specify supplied trays, brackets, tool boards, etc. required to hold equipment.
Fire Department retains right to change placement or brackets, trays etc. after pre build visit. / ☐ / ☐ / Click or tap here to enter text. /
18 / Lighting / Compliant LED emergency and ground lighting required. Body mounted left, right and rear 12 volt independently controlled scene lighting required. / ☐ / ☐ / Click or tap here to enter text. /
19 / Vehicle shall be wired for the use of a Fire Department supplied portable generator. / 120-volt duplex outlets will be available on all four corners of the body. Duplex outlets shall be provided with a weather proof cover.
Preferred location for generator will be in the rear body compartment on a roll out tray. / ☐ / ☐ / Click or tap here to enter text. /
20 / All labelling shall be in metric units and English / ☐ / ☐ / Click or tap here to enter text. /
21 / Plumbing for a deck gun. / Minimum 76 mm / 3” / ☐ / ☐ / Click or tap here to enter text. /
22 / Hose bed designed to store 300 meters of 100mm hose,300 meters of 65 mm hose and 150 meters of 45mm hose. / ☐ / ☐ / Click or tap here to enter text. /
23 / Hard suction shall be stored in a high location / Suction is seldom used. Can be placed in a hard to access location. / ☐ / ☐ / Click or tap here to enter text. /
24 / Back up Cameras (3) / One rear to activate with reverse or on command and either side to active with turn signal. Screen will be ergonomically visible to the driver/operator. / ☐ / ☐ / Click or tap here to enter text. /
25 / Door mounted mirrors, heated and remote adjustable. / Preferred / ☐ / ☐ / Click or tap here to enter text. /
26 / Pump compartment and outlet freeze proofing required for northern operations / Detail measures to comply with this requirement. / ☐ / ☐ / Click or tap here to enter text. /
27 / Shorepower Autoeject and airbrake inlet nipple. / Placement on drivers side between cab doors. / ☐ / ☐ / Click or tap here to enter text. /
28 / Compartment Space / Manufacturer is expected to maximize available space for equipment. / ☐ / ☐ / Click or tap here to enter text. /
29 / Engine and Transmission / Minimum 400 hp engine with appropriate transmission to match / ☐ / ☐ / Click or tap here to enter text. /
30 / Auxiliary Braking / Provide details of recommended auxiliary braking system / ☐ / ☐ / Click or tap here to enter text. /
31 / Two-way radio antenna / Vehicle will have an antenna and will be wired for the Fire Department supplied radio / ☐ / ☐ / Click or tap here to enter text. /
32 / Tires / Spec’d to perform in Northern Ontario conditions for all seasons, majority of operation on paved roads at urban speeds. / ☐ / ☐ / Click or tap here to enter text. /
33 / Air horns and siren / Bumper mounted air horns with a pull cord controller accessible from either the drivers or officers seat.
100 watt siren with a Whelen controller to match fleet. / ☐ / ☐ / Click or tap here to enter text. /
34 / Multiplexed electrical system / ☐ / ☐ / Click or tap here to enter text. /
35 / Body doors / Roll up doors preferred. Detailed exceptions permitted for justifiable purposes. / ☐ / ☐ / Click or tap here to enter text. /
36 / Traffic Advisor / Installed at rear of apparatus flush mounted and protected from damage caused by climbing onto hosebed. Controller accessible from either drivers or officers seat. / ☐ / ☐ / Click or tap here to enter text. /
37 / Hosebed and upper storage access / Detail how the hosebed will be accessed in a safe compliant manner. / ☐ / ☐ / Click or tap here to enter text. /
38 / Paint and Decaling / Shall be designed to compliment existing Fire Department vehicles / ☐ / ☐ / Click or tap here to enter text. /
39 / Electronic Stability Control / Detail manufactures specifics / ☐ / ☐ / Click or tap here to enter text. /
40 / Traction Control / Detail manufactures specifics / ☐ / ☐ / Click or tap here to enter text. /
41 / Wheel Well Covers / Insides of wheel wells shall be shielded to prevent road debris from coming into contact with truck components. / ☐ / ☐ / Click or tap here to enter text. /

1