The following table is an actual example of evidence that has been accepted towards a qualification. Generic terms have been used to assist candidates.
Code / Title / Typical EvidenceMSAENV272B / Participate in environmentally sustainable work practices / Training records:
HSE
HSE Procedure,
Waste management policy,
Log book entries that include:
Reporting losses
Environmental hazards
Energy targets
MSAPMOHS110A / Follow emergency response procedures / Training records:
Site emergency procedure training
MSAPMOHS200A / Work safely / Training records:
Hazard identification,
Risk assessment
Emergency response
PPE
Site HSE policy
Site HSE procedure (1)
MSAPMSUP100A / Apply workplace procedures / Training records:
Companies industry
Companies product
Company Organogram
Plant Overview
Job description (1)
Production plans
Daily Instruction/orders
MSAPMSUP102A / Communicate in the workplace / Log book entries that include:
Instruction received
Task planning
Task completion
Communicate result
Work order that you raised
MSAPMOPS401A / Trial new process product / Process Unit Test run data,
Log Book entries that include:
Test run aim
Test run date
Process setup
Duration
Sampling, testing and records
Documentation
Results
Communicate results
Return plant to normal
Code / Title / Typical Evidence
PMAOPS411B / Manage plant shutdown and restart / Training records:
Unit emergency procedures
Site shutdown procedures ( 2 pages only)
Site startup procedures ( 2 pages only)
Log Book entries that include:
Cause of shutdown
Use of procedures
Communicate event
PMAOPS101C / Read dials and indicators / Training records:
Operator training
Readings card/sheet
Log book entries that include:
Out of range readings actions
PMAOPS201B / Operate fluid flow equipment / Training records:
Pumps
Pump work order
Pump readings
Log book entries that include:
Out of operating range actions
Pump isolation & deisolation
PMAOPS204B / Use utilities and services / Training records:
Plant Utilities
Hazards of Utilities
PMAOPS205B / Operate heat exchangers / Training records:
Exchanger
Exchanger work order
Exchanger readings
Log book entries that include:
Out of operating range actions
Exchanger isolation & deisolation
PMAOPS221B / Operate and monitor prime movers / Training records:
Turbines
Turbines work order
Turbines readings
Log book entries that include:
Out of operating range actions
Turbine isolation & deisolation
PMAOPS222B / Operate and monitor pumping systems and equipment (P) / Training records:
High capacity pumps
High capacity pumps work order
High capacity pumps readings
Log book entries that include:
Out of operating range actions
High capacity pumps isolation & deisolation
Code / Title / Typical Evidence
PMAOPS223B / Operate and monitor valve systems / Training records:
Valves
Valves work order
Log book entries that include:
Out of operating range actions
Valves isolation & deisolation
PMAOPS224B / Provide fluids for utilities and support / Training records:
Plant Utilities
Log book entries that include:
Managing utilities
Utilities readings
Out of operating range actions
Communicate actions
PMAOPS231B / Control gas odourisation / Training records:
Stench addition
Log book entries that include:
Managing Stench addition
Stench addition readings
Out of operating range actions
Stench addition isolation & deisolation
PMAOPS240B / Store liquids in bulk / Training records:
Oil movements
Log book entries that include:
Managing Oil/product movements
Oil movements readings
Out of operating range actions
Equipment isolation & deisolation
PMAOPS301B / Produce product by distillation (P) / Training records:
Crude Unit Controller
Log book entries that include:
Monitoring distillation process
Distillation readings
Out of operating range actions
Production rate changes
Production quality changes
Unit shutdown and start up (As per procedure)
PMAOPS302B / Operate reactors and reaction equipment / Training records:
Reactors
Reactors readings
Log book entries that include:
Out of operating range actions
Reactors shutdown and start up (As per procedure)
Code / Title / Typical Evidence
PMAOPS303B / Operate furnaces to induce reaction / Training records:
Furnaces
Furnaces readings
Log book entries that include:
Out of operating range actions
Furnaces shutdown and start up (As per procedure)
PMAOPS304B / Operate and monitor compressor systems and equipment (P) / Training records:
Compressor
Compressor readings
Log book entries that include:
Out of operating range actions
Compressor isolation & deisolation
PMAOPS307B / Transfer bulk fluids into/out of storage facility (P) / Training records:
Oil movements
Log book entries that include:
Managing Oil/product movements
Oil movements readings
Out of operating range actions
Equipment isolation & deisolation
PMAOPS323A / Operate and monitor heating furnace / Training records:
Furnace
Furnace readings
Log book entries that include:
Out of operating range actions
Furnace isolation & deisolation
PMAOPS326B / Produce product using gas absorption / Training records:
Treating vessels
Treating vessels readings
Log book entries that include:
Out of operating range actions
Treating vessels isolation & deisolation
PMAOPS329B / Produce product using liquid extraction / Training records:
Light Ends Splitter
Light Ends Splitter readings
Log book entries that include:
Out of operating range actions
Light Ends Splitter isolation & deisolation
PMAOPS402A / Respond to abnormal process situations / Training records:
Unit emergency procedure training
MEMO7033B / Operate and monitor basic boiler / Training records:
Steam ticket
MEMO7034A / Operate and monitor intermediate class boiler (P) / Training records:
Steam ticket
Code / Title / Typical Evidence
MSAPMOHS216A / Operate breathing apparatus / Training records
MSAPMOHS205A / Control minor incidents / Training records
MSAPMOHS210B / Undertake first response to non-fire incidents / Training records
MSAPMOHS212A / Undertake first response to fire incidents / Training records
PMAOHS213B / Undertake fire control and emergency rescue / Training records
PMAOMIR418B / Coordinate incident response / Training records
PMAOHS511A / Manage emergency incidents / Training records
PMAOMIR512B / Establish incident response preparedness and response systems / Training records
PMAOMIR418B / Coordinate incident response / Training records
PMASUP440B / Commission/recommission plant / Evidence includes:
New plant design review (Review meeting minutes)
New plant commissioning planning (Schedule)
New plant commissioning (Procedure)
Monitor and document results (Log Book)
Update documentation (Procedures, manuals etc)
PMASUP441C / Decommission plant / Evidence includes:
Plant decommissioning planning (Schedule)
Plant decommissioning (Procedure)
Update documentation (Procedures, manuals etc)
PMAOPS521C / Plan plant shutdown / Evidence includes:
Maintenance , project plant work scope (Work scope)
Tasks and timelines (Schedule)
Communicate schedule (Emails)
Monitor shutdown against schedule
PMAOPS522A / Coordinate plant shut down / Evidence includes:
Work scope
Shutdown roster
Shutdown procedure
Plant handover document
Communicate shutdown results
Startup procedure
MEM18011C / Shutdown and isolate machines/equipment / Equipment (Any) shutdown procedure
MSAPMSUP292A / Sample and test materials and product / Training records:
Sampling
Log book entries that include:
Sample type, time, results, records
Code / Title / Typical Evidence
PMLSAMP200A / Collect routine site samples / Training records:
Sampling procedures
Sampling procedure
Log book entries that include:
Sample type, time, results, records
MSAPMOHS217A / Gas test atmospheres / Training records
MSAPMAPER200B / Work in accordance with an issued permit / Training records
MSAPMAPER201A / Monitor and control work permits / Training records
MSAPMPER202A / Observe permit work / Training records
MSAPMAPER300B / Issue work permits / Training records
MSAPMPER400A / Coordinate permit process / Training records
PMAOPS216B / Operate local control system / Training records:
PLC
Log book entries that include:
PLC use
PMASUP311A / Operate communications hub / Training records:
Radio communications
Log book entries that include:
Radio communications use
PMAOPS305B / Operate process control systems / Training records:
DCS
Log book entries that include:
DCS use
Controllers A/M
Trending
Alarms
Handover
PMAOPS405A / Operate complex control systems / Training records:
Process Controller
Log book entries that include:
Monitoring process
Process readings
Out of operating range actions
Production rate changes
Production quality changes
MSAPMOPS400A / Optimise process/plant area / Training records:
Process Controller
Log book entries that include:
Monitoring process
Process readings
Optimising actions
PMAOPS500A / Optimise production systems / Training records:
Senior Process Controller
Log book entries that include:
Monitoring process
Process readings
Optimising actions
Code / Title / Typical Evidence
PMAOPS505A / Control the process in abnormal situations / Training records:
Unit emergency procedure training