Worksheet 2 – Report results
Complete the following details:
NameName of Instructor
Detail the procedures in place in your laboratory to report results.
Detail the procedures in place in your laboratory to report discrepancies.
Attach some completed forms to this worksheet.
The following information has been included in a lab technician’s logbook. Use the laboratory datasheet to report the results.
Date: 24/07/07
Raw Water Sample ID# 2407ME - RW1
Turb on in-line sensor 0.34 in lab 0.35
pH on sensor 7.61 in lab 7.48
Color in lab 22HU
UV in lab 0.278
Fluoride 0.36
Odor cold was E1 and hot was E3
Prior to storage ID# 2407ME - PS1
Turbidity from meter 0.08 from lab 0.06
pH from meter 7.09 from lab 7.07
fluoride meter 0.84 lab 1.06 **
Free chlorine meter 2.4 lab 2.47
Odor cold Cc2, Hot Cc3
24 hr Composite ID# 2407ME - 24CMon
Monday turb 0.09, Color 2, UV 0.071, fluoride 0.88
24 hr Composite ID# 2407MW - 24CTues
Tuesday turb 0.08, Color 1, UV 0.074, fluoride 0.83
24 hr Composite ID# 2407MW - 24CWed
Wednesday turb 0.08, Color 2, UV 0.076, fluoride 0.83
QA Samples ID# 2407ME - QA1
Turb (Hi) 2.84, Turb (Lo) 0.192
pH 7.20 @ 18.7oC
Color (Hi) 30 Color (Lo) 5
Total Chlorine Residual (Hi) 2.7, (Lo) 0.27
Worksheet 2 – Report results Page 1 of 4
LABORATORY DATASHEET
Sample Source / Sample day/date / Result from ……. / Turb-idity
(NTU) / pH / Color (HU) @
456nm / UV abs/
cm @
254nm / Fluoride
(mg.L-1) / Residual Chlorine
(mg.L-1) / Odor / Comments
Adjustment Req
Free / Total / Cold / Hot
Raw / Lab
In-line
Diff.
Post-chemical dosing / Lab / 6.02 / OK nil adj
In-line / 6.07
Diff. / -0.05
Inflow-settled
Pre-lime / Lab / 0.4 / 4 / 0.101 / 0.24
In-line / 0.4
Diff. / 0.0
Settled
Post-lime
Underfloat / Lab / 7.50
In-line / 7.46
Diff. / +0.04
Filtered / Lab / 0.47 / #2
In-line
Diff.
Prior to storage / Lab
In-line
Diff.
After storage / Lab / 1.35
In-line / 1.32
Diff. / +0.03
24 hr composite / Mon
24 hr composite / Tues
24 hr composite / Wed
Worksheet 2 – Report results Page 4 of 4