Digital temperature controller Instructions
Product electrical characteristics:
Type
□Refrigeration □Heating □Cold or Hot
Output current: □ 10A □ 20A □ 30A
Sensor: □NTC □18B20
Input voltage: □12V □110V-240V
Temperature measurement range:-50℃~110℃
Resolution:temperature 0.1℃
Control accuracy:±0.1%℃
Refresh frequency:0.5S
Support for Fahrenheit and Celsius display switch
Environmental requirements:-10℃--60℃ humidity 20%--85%
Digital tube image design,Refrigeration indicates by snowflake Icon, Heating indicates by round sun Icon, process of refrigeration or heating indicates by Fan rotation icon
probe length of 2 meters
Wiring diagram
Panel icon indicator
Refrigeration condition display, snowflake Indicator is light on, green light is always light on. The green light flashes during the delay, Refrigeration relay pull, the fan revolved.
Heating condition display, round sun Indicator is light on, red light is always light on. The red light flashes during the delay, Heating relay pull, the fan revolved.
Function description:
1.Refrigeration, Heating, Cold and Hot control:
C Under the refrigeration mode:
Present temperature a≥Target temperature b, into the refrigeration state, Present temperature a≤(Target temperature b-Return difference temperature c), into stop status. (For example, If you want to control the temperature between 10~15℃. Temperature rises to 15℃,Start compressor, Temperature drop to 10℃ stop it, Press S to enter setup, Set target temperature b is 15℃, Set return difference temperature c is 5℃, It can keep the temperature between 10~15℃)
H Under the heating mode:
Present temperature a≤Target temperature b,into the heating state, Present temperature a≥(Set temperature b+ Return difference temperature c),into stop status. (For example, If you want to control the temperature between 30~35℃, Temperature rises to 35℃, Stop heating equipment, Temperature drop to 30℃ , starting heating equipment. Press S to enter setup, Set target temperature b is 30℃, Set return difference temperature c is 5℃, It can keep the temperature between 30~35℃)
CH Cold or Hot mode:
Present temperature a≥Target temperature b+ Return difference temperature c,into the refrigeration state;
Present temperature a≤Target temperature b- Return difference temperature c,into the hesting state;
Present temperature a≤Target temperature b,Stop refrigeration equipment,
Present temperature a≥Target temperature b,Stop heating equipment.
(For example, If you want to control the temperature between 5~-5℃,Temperature rises to 5℃,Starting refrigeration equipment,Temperature drop to -5℃, Starting heating equipment.Press S to enter setup,,Set target temperature b is 0℃, Set return difference temperature c is 5℃,It can keep the temperature between 5~-5℃)
2. Hightemperaturealarmfunctionanderrorfunction
The temperature of present is greater than the alarm temperature of setting, Buzzer will intervals make sounds and close all output controls. Press the E key to exit the alarm.
Thetemperatureofpresentishigherthantheuppertemperaturelimitwillalarm,digitaltubedisplayHHHHandclosealloutputcontrols.PresstheEkeytoexitthealarm.
3. Set target temperature
Under normal state, short press (SET) button and display is flicker, display the target temperature B at this time. Press + or - button to adjust the temperature, Short press SET button once again to save exit after the adjustment was completed.
4.P0-P5 Menu settings description
Undernormaldisplaycondition,LongpressSbutton,digitaltubedisplayP0,ShortpressSETkeytoenterP0-P5make corresponding settings,SetthecorrespondingvaluebyupanddownkeyandpressEkeytodetermine.
Restore factory settings by Hold down + - key meanwhile and power on.
Schedule:The significance of displaying characters When the main display window is set.
Symbol / Significance / Centigrade Range / Fahrenheit degree Range / Factory DefaultP0 / heating / refrigeration / heating and refrigeration mode / C/H/CH / C/H/CH / C
P1 / Return difference temperature / 0.1~15 / 0.1~27 / 2
P2 / Correction temperature / -7~7 / -13~13 / 0
P3 / Delay Time (Minute) / 0-10 / 0-10 / 3
P4 / High temperature alarm switch / OFF / OFF / OFF
P5 / Temperature mode(Centigrade and Fahrenheit degree) / CCCC/FFFF / CCCC/FFFF / CCCC