WP4325 COMSILENT

N2 BOOSTER DATA SHEET

WP4325CS Nitrogen Booster Data Sheet
Final Operating Pressure / Speed / UNITS
950 RPM (50 Hz)
Flow & Power / 1450 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 8.2-10.6 / SCFM
8.0 / HP
2900 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 8.1-10.5 / SCFM
8.0 / HP
4350 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 7.8-10.2 / SCFM
8.6 / HP
5000 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 7.4-9.7 / SCFM
8.6 / HP
Technical Specifications / Motor rating / 10 / HP
Current @ 400 Volts / 15 / Amps
Weight / 1310 / Pounds
Noise level @ 3 ft / 70 / dB(A)
Heat dissipation / 31,000 / Btu/hr
Cooling air needed / 2000 / CFM
Residual oil content at gas outlet (without filtration) / < 3 / mg/m3
Delta temperature (gas oultet vs. ambient) / 18 / °F
Operational ambient temperature range / 40-110 / °F
Operating pressure range / 1450-5000 / psig
Oil sump capacity / 6.1 / Quarts
Dimensions (L x W x H) / 60 X 32 X 62 / Inches
Cooling method / Air-Cooled
Drive type / Direct Drive
Stages/Cylinders / 4/4

*All data is with 5 % tolerance and is related to ambient conditions of 68 ° F and 14.7 PSIA.

Package Includes:

  • Feed tank run-permissive sensor (supplied loose)
  • Inlet Buffer Tank and Regulator Assembly
  • Intercoolers and aftercooler
  • Oil and water separators after the stages
  • Safety valve after each stage
  • 1st,2nd, 3rd, and 4th stage pressure gauges
  • Solenoid valves (115 V / 60 Hz) for automatic drainage of the separators
  • Unloaded starting relief and automatic condensate drain system
  • Condensate demister to easily dispose of condensate drainage
  • Assembly of compressor and electric motor
  • Resilient mounts including drainage hoses and air/gas outlet hose
  • 460/3/60 electric motor with IP 55 (TEFC) protection
  • Non-return valve mounted to air/gas outlet hose
  • Low oil pressure shutdown switch
  • High air/gas temperature shutdown switch mounted at the air/gas outlet of the compressor
  • Final gas filtration for oil free gas delivery
  • Compressor control system (including motor starter) for starting/stopping the compressor, and monitoring the oil level, air/gas outlet temperature and outlet pressure of the compressor
  • Complete package wired and mounted on a skid, and enclosed in a sound dampening canopy
  • Air/gas pressure sensor for automatic start/stop

Standard warranty is 15 months from date of shipment or 12 months after initial installation and start-up, whichever comes first. Ask your Sauer USA representative if your project requires an extended or alternative warranty period.

Optional equipment:

  • Final receiver packages with the necessary components supplied
  • Diesel motor driven
  • Modified for 50 Hz power supply
  • Customized controls for user specified monitoring and operation
  • Weather resistant canopy
  • Complete package rated for installation in a hazardous location (Class 1 Division 2, or Class 1 Division 1)

Sauer Compressors USA custom engineers solutions for our customers. Please inquire about options you may require which are not listed.