PinPoint
PFD-5XX Operator’s Manual
Basic Operation
Voltage Adjustment: Turn on PF or LF knob, auto switch and change voltage/vibration directory.
(On the right side of display show “v” light)
Frequency Adjustment: Press PF or LF knob 0.5 seconds at least,display flash then enter the frequency
adjustment function. (On the right side display show ”Hz” light).
Function (For technical person operation)
Enter> Press the Power key first, two red lights is on.
Press the PF (LF) knob at least 4 seconds continuously, show “End” on the display and the green
light is on.
Adjustment> Turning the knob to select the function item number then press it to adjust your option.
Abbreviation codes are as follow list.
Leave> Press the knob again, the numerical number will be saved and back home automatically.
Show “End” on the display and two red lights is on.
Abbreviation Codes List :
Item / Abrr. / Function / Range / Default / NoteEnd / Leave and Back Home / Ending
01: / On.d / ON delay timing / 0~25 sec. / 0.0 sec. / Delay start timing, RUN LED orange light on
02: / OFF.d / OFF delay timing / 0~25 sec. / 0.0 sec. / Delay stop timing, RUN LED green light on
03: / InU / Outside control signal
Invert / non-invert / No/Yes / No / Outside signal “ON”, select start or stop
04: / On.S / ON SOFT soft start timing / 0~10 sec. / 0.8 sec. / Curve modify, accelerate soft start function
05: / OFF.S / OFF SOFT soft stop timing / 0~2 sec. / 0.2 sec. / Curve modify, decelerate soft stop function
06: / bAnd / Frequency selection / L,H,HH,UH / L / 4 bands switch,45Hz~400Hz *note 1
07: / HI.U / Output voltage maximum / 0~250V / 220V / Controller has no voltage of amplification;
output voltage < or = input voltage
08: / LO.U / Output voltage minimum / 0~250V / 0V / The soft of vibratory output
09: / FUSE / Circuit breakers / 0.5,1,2… / 3A / Protection coil to avoid burning out
10: / STEP / Output voltage adjustment / 1~5V / 2V / Output voltage of numerical number
11: / 2nd / Two segment switch control / 0~250V / 0V / 0: Stop this function, input control by “AUX”.
12: / ALAr / Stop/alarm while no feeding / 0~180 sec. / 0 sec. / 0: Stop this function
13: / dISP / Adjust the display brightness / 1~8 / 2 / Depends on working environment
14: / HOP.C / Hopper full feeding control / No/Yes / No / Hopper stop or not whilele the bowl stop
15: / dUAL / Dual input control / No/Yes / No / PF and AUX I/O are connected control or not
Other Special Function: 1. Postion Check Control 2. Full Feeding Control 3. High/Low Range Control
*Note 1: L=45Hz~130Hz, H=70Hz~230Hz, HH=170Hz~330Hz, UH=270Hz~400Hz
Other Function
1. Lock (Lock) : Power on, press “POWER” key 4 seconds continuously. (Display left side show “lock” light ).
(Release) : Repeat the above procudre for release it.
2. Either PF or LF function: Power off, press PF (or LF) knob and “POWER” key. Turn off and restart for release it.
Connect Method
Conntect with 16mm metalconnector.
1. Connect with optical fiber, detection sensor, photoelectric sensor: pin 1 à “+V” brown color (inside CN6 can switch to +12V or +24V voltage), pin 2à “Out ” black color, pin 3 à “Gnd “blue color.
2. Connect with +12VDC or +24VDC voltage contact: pin 3 no contact (not connected),pin 1(+V),pin2(-V), à outside part which has voltage output control.
3. Conntect with normal switch, Relay No/Nc(non voltage contact): pin 1 not connected, pin 2,3 à switch
4. Connect with PLC part: pin 1 not connected, pin 2 à output (transistor C polarity), pin 3 à Gnd (transistor E polarity).
Model Description
PFD-5 2 0 P
Output Current/Outside Control □:3A +P:5A +A: AC contol +D: DC contol
+B: Hopper Control +HV: 380~440VAC
Number Of The Control 1: PF 2: PF+LF
Products Name
*Note 2: PF=Parts Feeder, LF=Linear Feeder, HOP=Hopper Feeder.
*Note 3: AC Control=AC 220V magnet or other AC control output.
*Note 4: DC Control=DC 24V magnet( max. 4 W) or other(PLC) DC control putput.
Unususal Display
PF:OC=PF Over Current/LF:OC=LF Over Current, -OH- =Over Hot,
-SH- =Output Short Circuit or Inside Short Circuit, -OU- =Over Voltage
Standard Specification
Model PFD-5XX / PFD-500 / PFD-510,520,530 / PFD-520P / PFD-510P / PFD-510HVOutput / Output Current (A) / 3A / 4A / 5A / 3A
Max. Output Voltage (V) / 0~100VAC/0~200VAC / 0~200VAC / 340VAC/400VAC
Output Freq. Range (Hz) / 45~180Hz / 45Hz~400Hz/4 bands / 45Hz~230Hz/2 bands
Input / AC singal phase (V) / 110VAC/220VAC / 220VAC / 380/440VAC
AC Power Freq. (Hz) / 50Hz/60Hz/±5%
Voltage Range (V) / 90~132VAC/180~264VAC / 180~264VAC / 320~480VAC
Operating Specific / Constant Voltage Output / Output Freq., Output Voltage Manual Set Up
Output Control / Sign Wave, PWM
Soft Start/Stop / Fix / Curve Type, Ajustable Speed
Freq. Accuracy/Resolation(Hz) / 0.02%/0.5%
Voltage Accuracy/Resolation(V) / 5%/1VAC
Outside Control Function / Outside Control Loading / Max. 4W, Max. Current 150mA/+24VDC
Start / Stop Control / Inside / Inside
High/Low Speed 2 Bands Control / Nil / Extra / Extra
ON/OFF DELAY Control / Nil / Inside / Extra
HOPPER Full Feeding Control / Nil / Inside/PFD-510 Nil / Nil
AC/DC Magnet Output Control / Nil / Extra / Extra
Twin Input (AND) Control / Nil / Inside / Inside
Isolate Input Conrol / 1 Set / 3 Sets/PFD510
1 Set / 3 Sets / 1 Set
Counter Control / Nil / Nil
No Feeding Stop Alarm Control / Nil / Extra / Extra
0~10VDC/4~20mA Speed Control / Extra / Extra
+24VDC/Relay Control / Nil / Extra / Extra
Temperature Range / 0~40℃
Hygro Range / Below 90% RH
Stand By Loss / 10W (240VAC)
10W
Chilled Method / Natural Wind / Natural /Fan Wind / Natural Wind
Protect Function / Over Voltage,Current,Temperature, Low Voltage,Output Short Circuit,
Power FUSE
Weight (net ) / 0.95Kg / 1.0Kg
Dimension / 170.5(L)X63.2(W)X85(H)mm
400(D) mm