Schedule of Accreditation
issued to
Calibration Laboratory - Akhnaton for Industrial Engineering
(Permanent & On-SiteCalibration)
113 Tomanbay st., El- Zeitoun
Cairo – Egypt
Valid to : August 2, 2013 / Issue Date: December 2, 2010 / Issue No. 3 / Schedule No.: 20302 BBrief Description of Measurement and Equipment Used / Calibration & Measurement Capability*
(±) / Range / Measured Quantity
Direct Comparison Method
/ 0.32 °C0.45°C
5.19 °C / from -35 °C to <100 °C
from 100°C to 350 °C
from 350 °C to 1200 °C / Temperature
(Sensor with it's Indicator)
Dry Heating Block
Manufuacture Hart Scientific, USA
Model 9140 , S.N A74043 & A84242
Dry Heating Block
Manufuacture Hart Scientific, USA
Model 9103 , S.N A84329
Dry Metal Block
Manufuacture ISOTHERMAL ,UK
Model VENUS 2140 , S.N 24325/2
Dry Metal Block
Manufuacture ISOTHERMAL , UK
Model PEGASUS 1200 , S.N24325/1
Digital Thermometer and Probe
Manufuacture Hart Scientific ,USA
Model 1521 & 5627
S.N A12701 & 562916
Platinium Resistance Thermometer (PRT)
Manufuacture Hart Scientific ,USA
Model5628 , S.N 1629
Thermocouple Type K with Digital Indicator
Manufuacture Dickson ,USA
Model TC200 , S.N 07163087 & 7012077 / TP 710000
(*)Calibration & Measurement Capabilities are to be experssed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximatly 95%.
Schedule of Accreditation
issued to
Calibration Laboratory - Akhnaton for Industrial Engineering
(Permanent & On-SiteCalibration)
113 Tomanbay st., El- Zeitoun
Cairo – Egypt
Valid to : August 2, 2013 / Issue Date: December 2, 2010 / Issue No. 3 / Schedule No.: 20302 BBrief Description of Measurement and Equipment Used / Calibration & Measurement Capability*
(±) / Range / Measured Quantity
Direct Comparison Method
/ 12 x 10-3 bar / Absolute Pressure GaugesFrom 0 to 7 bar / Pressure
(Pressure Guages)
Pressure Calibrator
Manufuacture DRUCK,UK
Model DPI603 , S.N 1761/98-11
700 bar Module
Manufuacture DRUCK,UK
Model PDCR2200-1939 , S.N 2705371
Absolute Module
Manufuacture DRUCK,UK
Model PDCR2200-1939 ,S.N 2699188
Portable Pressure Calibrator
Manufuacture DRUCK ,UK
Model DPI610 , S.N 61054935
Digital Pressure Gauge(0 : 20) bar
Manufuacture DRUCK,UK
Model DPI104, S.N 2713827
Digital Pressure Gauge(0 : 7) bar absolute
Manufuacture DRUCK,UK
Model DPI104, S.N2472097
Digital Pressure Gauge(0 : 700) bar
Manufuacture DRUCK,UK
Mdel DPI104, S.N2807149 / TP 780000
21 x 10-3 bar / Penumatic Pressure
from -1 to 20 bar
0.91 bar / Hydraulic Pressure
from 0 to 700bar
(*)Calibration & Measurement Capabilities are to be experssed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximatly 95%.
Schedule of Accreditation
issued to
Calibration Laboratory - Akhnaton for Industrial Engineering
(Permanent & On-SiteCalibration)
113 Tomanbay st., El- Zeitoun
Cairo – Egypt
Valid to : August 2, 2013 / Issue Date: December 2, 2010 / Issue No. 3 / Schedule No.: 20302 BBrief Description of Measurement and Equipment Used / Calibration & Measurement Capability*
(±) / Range / Measured Quantity
Direct Comparison Method
/ 0.91 mg33.87 mg
0.27 g / from 1 mgto <210 mg
from210g to <4000g
from 4000 g to < 34kg / Balances
(Mechanical & Electronic Balances)
Weight Set (1mg – 500g),CLASS E2
ZWIEBEL ,S.NZ0701109
Single Weight 1 kg,CLASS E2
METTLER TOLEDO,S.N15848
Single Weight 2 kg,CLASS E2
METTLER TOLEDO,S.N 15849
Single Weight 2 kg,CLASS E2
ZWIEBEL,S.NZ0701110
Single Weight 5 kg,CLASS E2
METTLER TOLEDO,S.N 15850
Single Weight 10 kg,CLASS E2
ZWIEBEL,S.N20701111
Single Weight 20 kg,CLASS E2
METTLER TOLEDO,S.N15852 / TP800000
(*)Calibration &Measurement Capabilities are to be experssed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximatly 95%.
كورنيش المعادى –برج رياض المعادى1- القاهرة –مصر Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt
تليفون : 5275227/ 5275225 /5275224 /5275220 (202) Tel.: (202) 5275220/5275224/5275225/5275227 فاكس : 5275226 (202)Fax: (202) 5275226