Newborn Specification Batch Analyzer for Samples on 96-well Microplates
Instrument Specifications
Physical Dimensions:
Height: 1960 mm (77.22'')
Width: 1310 mm (51.6'')
Depth: 760 mm (30.0'')
Weight: 610 kg (1345 lb)
Power Requirements
Power Consumption: 1500 VA
Mains Voltage: 100-240 V
Environmental Conditions:
Operating Temperature: 18-30C
Relative Humidity: 10-80%

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Samples:
Sample type: Blood disks punched from dried blood spots into 96-well plates
Sample identification: Barcode reader or key board input
Loading:
Continuous sample loading
Continuousreagent loading
Bulk Reagents
Washing and Rinsing: Automatic or Manual water filling
Liquid Waste capacity: Automatic disposal to a waste line or Manual disposal 16L
Capacity
Sample Capacity: 26 plates (2496 wells)
Reagent Capacity Up to 13 reagents cassettes
Heated Incubator Module: 12 plates
Shaking Module: 3 x 6 plates

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Low volume reagent pipette
Volume range: 5 – 50ul
Precision (CV%): <1.5%
Accuracy: Within ± 8%
High Volume reagent pipette
Volume range: 25 – 200ul
Precision (CV%): <1.5%
Accuracy: Within ± 8%
Measurement Unit
Measurement Mode: TRF, FI, Abs
Technical Data for UPS
Product Description: APC Smart-UPS SMT2200i 230 V
Device Type: UPS
Form Factor: External
Dimensions (WxDxH): 197 mm x 544 mm x 435 mm
Weight: 51 kg

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Input voltage: AC 230 V
Output Voltage: AC 230 V ±5% (50/60 Hz ±3 Hz) autosensing
Power Provided: 2200 VA
Battery: UPS battery – Lead Acid
Battery Form Factor: Plug-in module
Average Run Time: 7 min at full load
Manufacturer Warranty: 3 years electronics, 2 years battery warranty
Details
Expansion/ Connectivity
Interfaces: 1 x management – RS-232 – 9 pin D-Sub (DB-9)
1 x 4-pin USB type
Cables Included: 1 x serial cable
Compliant Standards: CE, C-Tick, GOST, PCBC, VDE, EN 500091-2
Features: Audible alarm
Software / System Requirements
Software Included: Drivers & Utilities, APC Power Chute Smart-UPS Bundle
Min Operating Temperature: 0ºC

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Max Operating Temperature: 40ºC
Humidity Range Operating: 0-95 %
Min Storage Temperature: -15 ºC
Max Storage Temperature: 45ºC
Humidity Range Storage: 0-95%
Max Altitude Operating: 3 km
Sound Emission: 45 dBA
Power Device
Output Connectors: 8 x power IEC 320 EN 60320 C13, 1 x power IEC 320 EN 60320 C19
Power Output Cords: 2 x IEC Jumpers
Output Waveform: Sinewave
Surge Suppression: Standard
Energy Rating: 320 Joules
Electrical Safety
Certifications: CE declaration of Conformity. VDE-GS id label in device
Component: Description
Chassis: Small form factor desktop chassis

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Processor: Intel Core i5-6500 Processor (6M Cache, 3.2 / 3.6 GHz) – minimum requirement
Chipset: Intel® Q150
Video controller: Intel® Integrated
Sound controller: Integrated audio
Network interface: Integrated Gigabit Ethernet
Memory: 4 UDIMM slots DDR4 2133 MHz; 8 GiB – minimum requirement
Hard drive storage: 1 TB or bigger hard disk drive 7200 RPM, SATA3
Optical storage: DVD ROM
Drive bays: One 5.25 inch external bay (Optical Disk Drives), one 3.5 inch internal bay (HDD)
Expansion slots: Slot 1: Low Profile, PCI Express 3.0 x16
Slot 2: Low Profile, PCI Express 3.0 x1
Slot 3: Low Profile, PCI Express 3.0 x4
Power supply: 210 W automatic voltage-sensing

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
I/O ports:
Two audio connectors (microphone and headphone) on front panel
Two USB 3.0 (front)
Four USB 3.0 (rear)
Two USB 2.0 (rear)
One integrated VGA port (rear)
Two display ports (rear)
Three audio connectors (audio line in, audio line out and microphone-in) on rear panel
One RJ45 connector (rear)
Serial port (rear)
Second serial ports (rear)
Mouse: USB Optical Mouse Black

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Keyboard: Preferred: USB full size keyboard black- English Euro
Operating system : PKI costume Image: Windows 7 Professional 64 preinstalled through downgrade rights in Windows 10 Pro English
Microsoft Office : Windows Office 2013
Warranty: 3 years on-site
Monitor: 19'' Widescreen Flat Panel Display
Size: 19.0 viewable image size
Aspect ration: 5:4
Response time: 8 ms grey to grey
Brightness: 250 cd/m2 typical
Contrast ratio: 1000 to 1
Horizontal viewing angle: 178°
Vertical viewing angle: 178°

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Connections: 1 x HDMI, 1 x VGA, 1 x Display port v.1.2, 2 x USB 2.0 ports, 2 x USB 3.0 ports (1 upstream, 4 downstream). VESA mount 100mm.
Optimal preset resolution: 1280 x 1024 at 60 Hz
Pixel pitch: 0.29 mm
Operating voltage: 100 to 240 V 50/60 Hz
Energy consumption: 14 W typ, 38 W max, standby/sleep <0.3 W
Operating environment:
Temperature, operating/ storage: 0 to 40°C / -20ºC to 60°C
Relative humidity (non-condensing): 10...80 %

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Chassis:
Parameter / With stand / W/o stand
Height compressed landscape/ extended portrait / 370 / 500 mm / 334 mm
Width / 406 mm / 406 mm
Depth / 180 mm / 50 mm
Weight with packaging / 6.61 kg
Terms and conditions:
Remarks: Includes start-up reagents and consumables. Supplier must have the ability to provide a formal commitment that reagent – machine compatibility will last up to the wear and tear life of the machine (At least 10 years)

BIDFORM

(TechnicalSpecification)

“FORENVELOPE1”

Bidno.: BAC3-NIH-IHG-16-311

Date : May 22, 2017

Unit : NIH-IHG

REQUIREDSPECIFICATIONS / OFFEREDSPECIFICATIONS / REFERENCES(include
Supportingdocuments) / COMMENTS/REMARKS
(clarifyinclusion/exclusion) / EVALUATION
Warranty: From date of installation, two year warranty on parts and services
Training: LOCAL training for all Laboratory Personnel and IT personnel; International training for key point Lab personnel
Terms: 30 days after installation
Delivery period: 6 to 12 weeks after receipt of valid Purchase Order

Note: Pls.fill-upallapplicablecolumns.

End-User:SignatureofRepresentative______

NameofRepresentative______

Position______

______Company______

End-user/Representative Address ______

Telephone/Fax/E-mail______