Software Release Notes
CN51 OS v2.11
Microsoft Windows Embedded Handheld
Overview
This is an OS release of Windows Embedded Handheld 6.5 for the CN51 mobile computer.
Supported Hardware
All CN51 configurations
Version numbers
2.00 Release / 2.02 Release / 2.10 Release / 2.11 ReleaseOS / 2.00.01.0078 / 2.02.01.0103 / 2.10.02.0051 / 2.11.04.7
IDLCommon / 4.02.00.2237 / 4.02.00.2337 / 4.03.01.78 / 4.03.01.78
DHCP_Client / 1.04.00.24 / 1.04.00.24 / 1.04.02.41 / 1.04.02.41
Funk / 2.02.01.114 / 2.02.01.114 / 2.02.02.166 / 2.02.02.166
IBI / 6.02.01.46 / 6.02.01.46 / 6.10.03.129 / 6.10.03.129
IDLLSRK / 121.010223.13090.1209 / 121.010223.13090.1209 / 1.31.01.38 / 1.31.01.38
Intermec_Settings / 5.91.01.62 / 5.91.01.62 / 6.00.03.166 / 6.00.03.166
ITCWifiMgt / 1.02.00.40 / 1.02.01.43 / 1.02.02.47 / 1.02.02.47
IVA_Utilities / 5.91.01.52 / 5.91.01.52 / 6.00.03.96 / 6.00.03.96
IVADCE / 6.04.01.50 / 6.04.01.50 / 6.10.03.165 / 6.10.03.165
IVADCEDrivers / 1.08.01.169 / 1.08.01.169 / 1.10.03.343 / 1.10.03.343
IVADeviceSettings / 6.03.01.31 / 6.03.01.31 / 6.10.03.91 / 6.10.03.91
IVAPAL / 6.03.01.69 / 6.03.01.69 / 6.10.02.150 / 6.10.02.150
In2Decode / 1.00.01.11 / 1.00.01.11 / 1.10.03.29 / 1.10.03.29
IVAVirtualWedge / 6.03.01.24 / 6.03.01.24 / 6.10.03.79 / 6.10.03.79
NetworkConfiglet / 7.30.00.59 / 7.30.00.59 / 7.30.02.99 / 7.30.02.99
Printer_Configlet / 2.31.11.9 / 2.31.11.9 / 2.40.13.120 / 2.40.13.120
SS_Client / 470.000264.13233.0808 / 470.000265.13325.0816 / 4.90.02.310 / 4.90.02.310
TCO_GUI / 2.00.01.17 / 2.00.01.17 / 2.11.02.42 / 2.11.02.42
WWANConfiglet / 2.00.11.38 / 2.00.11.41 / 2.10.02.72 / 2.10.02.72
WAPI / 1.04.01.19 / 1.04.01.19 / 1.04.02.35 / 1.04.02.35
New Functionality
2.11 Release
· Updated AKU to the latest version (43), which includes support for SHA-2.
· Updated BT power sequencing.
2.10 Release
· Added the ability to configure multiple charging indicators
· Added keyboard backlight
Functionality Improved In This Release
2.11 ReleaseID / Description Summary / Subsystem
EWR-15508 CN51 Bluetooth cannot turned on / Updated BT power sequencing / BT
EWR-15018 / Added support for SHA-2 / OS/BSP
2.10 Release
ID / Description Summary / Subsystem
WECVII-4149 / Improvements made to power state transitions / Power
WECVII-3991 / Fix provided to copy files to USB Mass Storage device / USB
WECVII-3964 / ActiveSync disconnects no longer occurring when transferring small files using Belkin USB hub / USB
WECVII-4016 WECVII-3977 WECVII-3998 / ActiveSync stability improved while going through power state transitions / USB
WLAN-313 / Wi-Fi scan accuracy with CloneNGo has been
addressed / WLAN
CSA-408 / Loading original backup settings XML with
ScanNGo now handles larger XML files / SmartSystems
WSL-589 / Intermittent audio issue on devices out of box has
been addressed / Audio
CSA-520 / Licenses are now retained if users flash an older
OS onto the device
WECVII-4344
WECVII-4250 / Clean boot procedure message was updated / OS/BSP
WECVII-4092 / Battery life improved / Power
WECVII-3997 / Device will wake from suspended state by
plugging in USB cable to USB charge cup / USB
CSA-391 / WWAN Information now showing in Device Health
Dashboard / DevHealth
WECVII-3958 / ActiveSync connection performance with USB
cable improved / USB
WECVII-3954
CSA-378 / Battery Temperature reporting is now more
consistent / Battery
WECVII-4013 / File transfer speeds have been improved while
using serial ActiveSync / OS/BSP
WECVII-3989 / CloneNGo stability improved / Device Management
WLAN-310 / Roaming performance improved on Cisco
network / WLAN
WECVII-3986 / Autouser.dat behavior corrected / OS/BSP
WECVII-3963 / High Contrast Black theme made improvements
to text for better visibility / OS/BSP
WSL-246 / Smoother transitions during screen rotation
WECVII-3949 / ActiveSync reliability after original flash and clean
boot is fixed / USB
CSA-381 / WWAN health poll period is now shown in
Intermec Settings / Settings
WECVII-3953 / Device is now able to remove CoPilot / OS/BSP
CSA-387 / Collect Abuse History option is now shown in
Intermec Settings / Settings
2.02 Release
ID / Description Summary / Subsystem
WSL-540 / Support for _Autoflash.img added to this release. / BSP
WECVII-4143 / Audio on UMTS has been improved during phone calls. / WAN
WECVII-4100 / Updated logic for Carrier Selection application. / WAN
WECVII-4098 / SPRINT: Text message received from voice mail
system every time radio registers on network has been addressed / WAN
WECVII-4088 / Local keypad tones when dialing a phone number
can now be heard / WAN
WECVII-4061 / CN51 WM SDR Pilot units can switch to Sprint
Carrier / WAN
WECVII-4055 / Improvements made for ActiveSync usage after
original flash and clean boot. / USB
WECVII-4018
WECVII-3971 WECVII-3961 WECVII-3951 / Ethernet performance has been improved. / USB
WECVII-4009 / USB host mode functionality has been enhanced. / USB
WECVII-4007 / Performance during heavy ITE usage has been
optimized. / Power
WECVII-4002 / Updates made to performance with vehicle dock / USB
WECVII-3993 / MSR usage has been improved. / USB
WECVII-3976 / Relaxation test is failing if the device is left on the
Power screen. / Power
WECVII-3972 / Fixed issue with audio files not playing right away. / Audio
WECVII-3968 / Devices with FlexNet radios now perform better
when going in and out of various power states. / USB
WECVII-3957 / Optimized current draw during hibernate. / Power
WECVII-3955 / Devices now perform better going in and out of
low power state. / Power
WECVII-3947 / Audio quality has been greatly improved while
device is in vehicle dock. / USB
WECVII-3941 / Handera SD50 vehicle dock/USB flash drives
performance has been improved. / USB
CSA-345 / CloneNGo resource management has been
optimized. / SmartSystems
Additional Information
The CN51 handheld computer manual and downloads are located at:
www.intermec.com | Products | Computers | Handheld Computers | CN51
Support Assistance
For product assistance or to report an issue/observation, contact Technical Support by calling 1- 800-755-5505 then option 4, 2. Outside North America, contact your normal support persons and they will enter a Knowledge Central case. If you would like to submit an online case, follow this link: http://intermec.custhelp.com/app/ask. If you don’t have an account, one can be created via the link on the right hand side.
Upgrade Instructions
Instructions for SD card upgrades:
1. Place “AutoFlash.img” and “IBOOT.nb0” files on a blank microSD card.
2. Hibernate the device.
3. Remove the battery and insert the SD card.
4. Replace the battery and put the device on charge. The OS upgrade will begin.
5. During the upgrade process, status messages will update along the bottom of the screen.
6. When the “Autoflash Complete” message is displayed you can remove the SD card and replace the battery to reboot the device.
Clean Boot Instructions
1. Reboot the device.
2. Press and hold the yellow I/O button.
3. Hold until message pops up stating “Release IO button”.
4. A new message will pop up stating “Enter first key in 20 seconds”. Press any key on the keyboard.
5. Another new message will pop up stating “Enter second key in 6 seconds”. Press any other key on the keyboard.
6. New message “Reconfirm first key in 6 seconds”. Press same key from step 4.
7. New message “Reconfirm second key in 6 seconds”. Press same key from step 5.
8. If completed correctly, a message will pop up stating “Cleanboot Confirmed”. If not, restart at step 1. If any of the time restrictions are exceeded in steps 4-7, the cleanboot will be aborted.
Device Management
CloneNGoTM
CloneNGoTM is a license free application that ships on every CN51 running Windows Embedded Handheld 6.5 that greatly simplifies and expedites configuration. This powerful application will clone all settings from a fully configured “master” unit, to a completely un-configured “client” unit, via an 802.11 connection with minimal user intervention. The CloneNGo User Guide is located at:
www.intermec.com | Products | Computers | Handheld Computers | CN51 | Manuals
SmartSystems
SmartSystems Foundation 4.70 is required for use with CN51 devices. This is available for download from www.intermec.com.
Application Support
All applications referenced in this section are for CN51 running Windows Embedded Handheld 6.5 only.
HTML5
HTML5 1.10 (WVGA version) is required for use with CN51 devices. A field test version has been placed in the /FlashFileStore directory. Visit http://www.intermec.com/support/downloads/ to get the released version.
ITE
ITE 1.40 is required for use with CN51 devices. Visit
http://www.intermec.com/support/downloads/ to get the released version.
Intermec Launcher
Launcher 2.20 is required for use with CN51 devices. Visit
http://www.intermec.com/support/downloads/ to get the released version.
Intermec Browser
Browser 2.10 is required for use with CN51 devices. Visit
http://www.intermec.com/support/downloads/ to get the released version.
Intermec Developer Libraries
Developer Resource Kits can be downloaded from
http://www.intermec.com/support/downloads/.
.NET application
Microsoft recommends that .NET applications use the form property ‘TopMost’ set to True in order to ensure the applications remain maximized.
Windows Mobile 6.5 Gesture Support
Gesturing is now supported by WM 6.5. This means that applications using listbox, listview, treeview, webview, or tab control will need to be aware of how the Windows GUI interprets the gestures. Please visit the Developer’s Forum (community.intermec.com) for more information.
CN50 Accessories
The CN51 has been designed so that it is compatible with most previous generation CN50 accessories. This includes batteries, snap-on adapters, and charge docks. Note: original CN50 batteries are not “smart” batteries so information provided to the Device Health Monitoring will be limited to charge state only.
Best Practices
1. When using Bluetooth audio and Wi-Fi together, you can improve performance by configuring the Wi-Fi connection profile to connect to an available Access Point. It is also recommended to limit the radio band to only the band that you are using. When not using Wi-Fi, turn off the
802.11 radio to maximize Bluetooth performance.
2. When using CloneNGo, it’s best to have Funk Security enabled.
3. For enhanced performance, we recommend that you close the camera application once you are no longer using it.
4. Once you start Sensor Calibration, it’s best to complete the process prior to closing the application. Closing the application too early may cause calibration settings not to be saved. If sensor calibration appears incorrect (slow screen rotation, etc.) use the Sensor Calibration App to repeat the calibration process.
Version History
Version / Date Available2.11.04.7 (Maintenance Release) / October 2015
2.00.01.0078 (Official Release) / September 2013
2.02.01.0103 (Maintenance Release) / February 2014
2.10.02.0051 (Official Release) / July 2014