SECTION 10 21 13
TOILET PARTITIONS
Display hidden notes to Specifier. (Don't know how? HYPERLINK "http://www.arcat.com/sd/display_hidden_notes.shtml" Click Here)
** NOTE TO SPECIFIER ** Bradley Corp.; powder coated steel, stainless steel, plastic, and phenolic core toilet enclosure, privacy screen and urinal screen products.
.
This section is based on the products of Bradley Corp., which is located at:
W142 N9101 Fountain Blvd.
Menomonee Falls, WI 53051
Toll Free Tel: 800-BRADLEY
Tel: 262-251-6000
Fax: 262-251-5817
Email: request info ()
Web: www.bradleycorp.com
[ Click Here ] for additional information.
Bradley is the industry's leading manufacturer of plumbing fixtures and washroom accessories designed for high traffic commercial hand washing applications. Headquartered in Menomonee Falls, Wisconsin, Bradley serves a diverse customer base ranging from small local facilities to international corporations. The company boasts the greatest depth and breadth of commercial plumbing products in the world. Architects and Specifier look to Bradley for the most innovative products in categories such as Multi-Station Lavatory Systems and Terreon(r) Solid Surface Products.
1 GENERAL
1.1 SECTION INCLUDES
** NOTE TO SPECIFIER ** Delete items below not required for project.
1.1.1 Powder coated steel partitions.
1.1.2 Stainless steel partitions.
1.1.3 Plastic partitions.
1.1.4 Phenolic core partitions.
1.2 RELATED SECTIONS
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
1.2.1 Section 03 30 00 - Cast-in-Place Concrete.
1.2.2 Section 04 27 23 - Cavity Wall Unit Masonry Unit Masonry Assemblies: Anchorage to masonry substrates.
1.2.3 Section 05 50 00 - Metal Fabrications.
1.2.4 Section 06 11 16 - Mechanically Graded Lumber.
1.2.5 Section 10 28 00 - Toilet, Bath, and Laundry Accessories.
1.3 REFERENCES
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
1.3.1 ASTM A 240 - Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
1.3.2 ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
1.3.3 ASTM A 666 - Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar.
1.3.4 ASTM A 743/A 743M - Standard Specification for Castings, Iron-Chromium, Iron-Chromium-Nickel, Corrosion Resistant, for General Application.
1.3.5 ASTM B 86 - Standard Specification for Zinc and Zinc-Aluminum (ZA) Alloy Foundry and Die Castings.
1.3.6 ASTM B 221 - Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
1.3.7 ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
1.3.8 ICC/ANSI A117.1 - Accessible and Usable Buildings and Facilities, as applicable to toilet compartments designated as accessible.
1.3.9 United States Green Building Council (USGBC): LEED Green Building Rating System.
1.4 DESIGN / PERFORMANCE REQUIREMENTS
** NOTE TO SPECIFIER ** Retain paragraph below for Powder Coated Steel and Stainless Steel partitions.
1.4.1 Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84 by qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1.4.1.1 Flame-Spread Index: 0.
1.4.1.2 Smoke-Developed Index: 0.
** NOTE TO SPECIFIER ** Retain paragraph below for Plastic Toilet partitions. Select Class B or Class C as required.
1.4.2 Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84 by qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1.4.2.1 Flame-Spread Index: Not greater than 75 (Class B).
1.4.2.2 Flame-Spread Index: Not greater than 200 (Class C).
1.4.2.3 Smoke-Developed Index: 450.
** NOTE TO SPECIFIER ** Retain paragraph below for Phenolic Core Toilet partitions. Select Class B or Class C as required.
1.4.3 Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84 by qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1.4.3.1 Flame-Spread Index: Not greater than 30.
1.4.3.2 Smoke-Developed Index: 110.
1.4.4 Conform to ICC/ANSI A117.1 - Accessible and Usable Buildings and Facilities, as applicable to toilet compartments designated as accessible.
1.5 SUBMITTALS
1.5.1 Submit under provisions of Section 01 30 00 - Administrative Requirements.
1.5.2 Product Data: Manufacturer's data sheets on each product to be used, including:
1.5.2.1 Data sheet indicating specified panel, pilaster, door, hardware and fastening.
1.5.2.2 Preparation instructions and recommendations.
1.5.2.3 Storage and handling requirements and recommendations.
1.5.2.4 Installation methods.
1.5.3 Shop Drawings: Submit plans, elevations, and detail section; indicate overall dimensions, material thickness, location and size of product, and mounting provisions and methods.
** NOTE TO SPECIFIER ** Delete the following paragraphs if LEED is not applicable.
1.5.4 LEED Submittals:
1.5.4.1 Product data for Credit MR 4: Indicate percentages by weight of postconsumer and preconsumer recycled content, and product cost.
** NOTE TO SPECIFIER ** Retain paragraph below for LEED for Schools project. Below applies to accessories containing melamine components.
1.5.4.2 Laboratory Test Reports for Credit IEQ 4: For accessory components made from composite materials: Indicate compliance with testing and product requirements of the California Department of Health Services ""Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers."
** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
1.5.5 Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
1.5.6 Verification Samples: For each finish product specified, two samples, minimum size 2 inches (52 mm) square, representing actual product, color, and patterns.
1.5.7 Manufacturer's Certificates: Certify products meet or exceed specified requirements.
1.6 QUALITY ASSURANCE
1.6.1 Manufacturer Qualifications: Manufacturer with minimum 5 years experience in the manufacture of the product types specified. If requested submit a list of successful installations of similar products for evaluation by Architect.
1.6.2 Accessibility Requirements: Comply with requirements of ICC/ANSI 117.1, and with requirements of authorities having jurisdiction.
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
1.6.3 Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1.6.3.1 Finish areas designated by Architect.
1.6.3.2 Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
1.6.3.3 Refinish mock-up area as required to produce acceptable work.
1.7 DELIVERY, STORAGE, AND HANDLING
1.7.1 Deliver and store products in manufacturer's unopened packaging until ready for installation.
1.7.2 Do not deliver toilet compartments to site until building is enclosed and HVAC systems are in operation.
1.7.3 Lay cartons flat, with adequate support to ensure flatness and to prevent damage to pre-finished surfaces.
1.8 PROJECT CONDITIONS
1.8.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
1.9 WARRANTY
** NOTE TO SPECIFIER ** Retain one of the following 4 paragraphs below for partition type(s) specified.
1.9.1 Powder Coated Steel Toilet Partitions: Against rust-out: 15 years.
1.9.2 Stainless Steel Toilet Partitions: Against rust-out: 15 years.
1.9.3 Plastic Toilet Partitions: Against corrosion, breakage, and delamination: 15 years.
1.9.4 Phenolic Core Toilet Partitions: Against delamination: 3 years.
1.9.5 Chrome Hardware: 5 years.
1.9.6 Stainless Steel Hardware: Lifetime.
2 PRODUCTS
2.1 MANUFACTURERS
2.1.1 Acceptable Manufacturer: Bradley Corp., which is located at: W142 N9101 Fountain Blvd.; Menomonee Falls, WI 53051; Toll Free Tel: 800-BRADLEY; Tel: 262-251-6000; Fax: 262-251-5817; Email: request info (); Web: www.bradleycorp.com
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
2.1.2 Substitutions: Not permitted.
2.1.3 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
** NOTE TO SPECIFIER ** Edit the following General paragraphs as required and applicable to project requirements. Delete the paragraphs that are not applicable.
2.2 STEEL TOILET PARTITIONS
2.2.1 Materials:
2.2.1.1 Metallic Coated Steel Sheet: ASTM A 653/A 653M, galvannealed commercial steel sheet suitable for exposed applications. Provide with mill phosphatized surface. Provide smooth material, without creases or ripples.
2.2.1.2 Zinc Aluminum Magnesium and Copper Alloy (Zamac): ASTM B 86.
2.2.1.3 Stainless Steel Sheet: ASTM A 240 or A 666, 300 series.
2.2.1.4 Stainless Steel Castings: ASTM A 743/A 743M.
2.2.1.5 Aluminum: ASTM B 221.
** NOTE TO SPECIFIER ** Retain the paragraph below for partition type(s) required.
2.2.2 Toilet Compartment Type:
2.2.2.1 Overhead braced.
2.2.2.1.1 Basis of Design Product: Bradley, Mills Partitions, Sentinel, Series 400.
2.2.2.2 Floor anchored.
2.2.2.2.1 Basis of Design Product: Bradley, Mills Partitions, Floor Braced, Series 500.
2.2.2.3 Ceiling hung.
2.2.2.3.1 Basis of Design Product: Bradley, Mills Partitions, Ceiling Hung, Series 600.
2.2.2.4 Floor and ceiling anchored.
2.2.2.4.1 Basis of Design Product: Bradley, Mills Partitions, Floor to Ceiling, Series 700.
2.2.3 Privacy Screen Type:
2.2.3.1 Floor anchored.
2.2.3.1.1 Basis of Design Product: Bradley, Mills Partitions, Floor Braced, Series 500.
2.2.3.2 Floor and ceiling anchored.
2.2.3.2.1 Basis of Design Product: Bradley, Mills Partitions, Floor to Ceiling, Series 700.
2.2.4 Urinal Screen Style:
2.2.4.1 Wall hung with wing bracket:
2.2.4.1.1 Basis of Design Product: Bradley, Mills Partitions, Model No. 2.
2.2.4.1.2 Provide chrome plated wing bracket for mounting to wall.
2.2.4.2 Floor anchored:
2.2.4.2.1 Basis of Design Product: Bradley, Mills Partitions, Model No. 3.
2.2.4.2.2 Floor mounted, requiring concrete floor, minimum 3 inches thick for anchoring.
2.2.4.2.3 Where indicated on Drawings, modify to become floor-to-ceiling mounted by changing mounting pilaster.
2.2.4.3 Wall hung with brackets:
2.2.4.3.1 Basis of Design Product: Bradley, Mills Partitions, Model No. 4.
2.2.4.4 Government-flanged with Wing Bracket:
2.2.4.4.1 Basis of Design Product: Bradley, Mills Partitions, Model No. 5.
2.2.4.4.2 Provide with continuous bracket in addition to wing bracket.
2.2.5 Door, Panel, and Pilaster Construction, General: Form edges with interlock to provide watertight fit without crown molding. Braze corners and finish smooth.
2.2.5.1 Provide exposed surfaces free of pitting, visible seams and fabrication marks, stains, telegraphing of core material, or other imperfections.
2.2.5.2 Core Material: Manufacturer's standard sound-deadening, water resistant honeycomb in thickness required to provide finished thickness for doors, panels and pilasters.
2.2.6 Door Construction: 1 inch (25 mm) thick, constructed from 0.0313 inch/22 ga (0.794 mm) galvannealed steel.
2.2.6.1 Provide each door with internal 0.0625 inch/16 ga (1.59 mm) and 0.0781 inch/14 ga (1.98 mm) welded reinforcements at top and bottom hinge locations, with factory installed concealed true gravity cam hinges.
2.2.7 Panel Construction: 1 inch (25 mm) thick, constructed from 0.0313 inch/22 ga (0.794 mm) galvannealed steel.
2.2.8 Grab-Bar Reinforcement: Provide concealed internal reinforcement for grab bars mounted on units.
2.2.9 Pilaster Construction: 1-1/4 inch (32 mm) thick.
** NOTE TO SPECIFIER ** Retain the paragraph below for gauge material required.
2.2.9.1 Constructed from 0.0375 inch/20 gauge (0.953 mm) galvannealed steel.
2.2.9.2 Constructed from 0.048 inch/18 gauge (1.219 mm) galvannealed steel.
2.2.9.3 Provide pilaster with internally welded bracket suitable to accept minimum 3 inch (76 mm) long, 5/16 inch (7.9 mm ) stainless steel hex bolt for leveling.
2.2.10 Headrail: Extruded anodized aluminum headrail with anti-grip profile. Provide fasteners for attachment to pilaster and stainless steel brackets to secure to wall.
2.2.11 Shoes: 4 inches (102 mm) high minimum, Type 304 stainless steel with No. 4 satin brushed finish. Secured to the inside face of the pilaster with stainless steel torx-head fasteners.
2.2.12 Urinal-Screen Construction: Matching toilet compartment panel construction
** NOTE TO SPECIFIER ** Retain paragraph below for floor-anchored, overhead-braced, and post-to-ceiling urinal screens.
2.2.13 Urinal-Screen Post: Manufacturer's standard post design
2.2.13.1 Material matching the thickness and construction of pilasters; with shoe and sleeve (cap) matching that on the pilaster.
2.2.13.2 Material 1-3/4-inch (44-mm ) square, aluminum tube with satin finish; with shoe and sleeve (cap) matching that on the pilaster.
2.2.14 Brackets (Fittings):
** NOTE TO SPECIFIER ** Retain one or both paragraphs below and select the Material required; if retaining both, indicate locations of each type of fitting on Drawings or by inserts. If necessary, revise to indicate fitting requirements for specific applications, e.g., "heavy-duty" urinal-screen brackets.
2.2.14.1 Stirrup Type: Ear or U-brackets;
2.2.14.1.1 Material: chrome-plated zamac.
2.2.14.1.2 Material: stainless steel.
2.2.14.2 Full-Height (Continuous) Type: Manufacturer's standard design.
2.2.14.2.1 Material: Aluminum.
2.2.14.2.2 Material: stainless steel.
2.2.15 Steel Sheet Finish: Manufacturer's standard powder coat finish, with [one color] [two colors] in each room.
2.2.15.1 Color: As selected by Architect from manufacturer's full range.
** NOTE TO SPECIFIER ** Retain paragraphs below for projects where standard hardware is adequate for traffic and use.
2.2.16 Hardware, Standard Duty: Manufacturer's standard chrome-plated zamac castings, including corrosion-resistant, tamper-resistant fasteners:
2.2.16.1 Hinges: Adjustable to hold doors open at any angle up to 90 degrees, with emergency access by lifting door.