DETENTIONS IN PORT OF KOPER IN THE YEAR 2005

1
Date & Place of Detention / 2
Vessel Name, Type, IMO No & GT / 3

Flag

/ 4
Owners
Operator

Charterers

/ 5
Classification Society / 6

PD

/ 7
Summary
03/01/2005
Koper /

SERENADE

General cargo
7116860
4255 / Italy / Monteverde Navigazione
Napoli
Italy / RINA / Detained for 9 days.
26 recorded deficiencies.
Wheelhouse bulkhead corroded through. Both accommodation air vent on monkey bridge corroded through. Accommodation air vent damper sized. On 2nd officer cabin window frame detached. Several self ignition lights inoperative. Funnel corroded through. Acetylene pipes connection improper. Gasket holder on store door corroded through. Galley door corroded through. Anchor ball improper size. Ropes made fast on warping drums. PS stopper inoperative. Improper gauges on all DO tanks. ON WT4 tank air pipe temporary repaired. On steering gear limit switch missing. In ER STB one frame bent and one frame holed. Several DO pipes leaking. QCV on three tanks inoperative. CO2 room bulkhead corroded through. Front bridge bulkhead corroded through. ER air vent corroded through. Emergency fire pump inoperative. Limit switches on davits inoperative. Galley air vent damper sized. Abandon drill failed. Emergency preparedness failed.
04/01/2005
Koper /

CATA

General cargo
7214234
2756 / Georgia / Uni Marine Management
Tarous
Syria / International Register of Shipping / Detained for 3 days.
23 recorded deficiencies.
Rudder back piece cracked. ORB entries not in accordance with instructions. Two wipers in wheelhouse inoperative. Glass in wheelhouse made of plexiglass. Funnel damper inoperative. Wheelhouse bulkhead corroded through and repaired with silicon. Accommodation bulkhead corroded through. Accommodation air vent corroded through. Monkey deck cracked and temporary repaired with canvas. PS lifeboat with some cracks. On lifeboat deck outside emergency lights missing. Front bridge bulkhead corroded through. On hold 2 hatch covers some frames cracked. FCSL air vent corroded through. Anchor washing line temporary repaired. QCV on emergency generator fuel tank inoperative. In hold 1 one deck girder corroded through. Sewage tank repaired with silicon. Oil pipe for stern tube made of rubber. Two QCV on fuel tank inoperative. OWS inoperative. ISM preparedness failed.
07/01/2005
Koper /

EUROCARRIER

Bulk carrier
7366128
15.627 / Cambodia / Diamond Marine Enterprises
Piraeus
Greece / Phoenix Register of Shipping / Detained for 6 days.
41 recorded deficiencies.
Wheelhouse bulkhead corroded through. Pilot cabin bulkhead corroded through. Glasses on navigational lights not in accordance with colreg 72. Wire on horn for manual activation torn. Accommodation air vent corroded through. Both funnel dampers do not close completely. Funnel door corroded through. Galley air vent damper sized. ER air vent corroded through. Skylight corroded through. On air condition room air vent damper sized. On AB cabin bulkhead corroded through. Glass on accommodation door crashed. 3rd engineer cabin bulkhead corroded through. Deck generator fuel tank without gauge and with improper fuel pipe connection. Self igniting lights inoperative. Tally room bulkhead corroded through. Electric bondage on cable line disconnected. Three bilge sounding pipes corroded through. Watch room bulkhead corroded through. Store bulkhead corroded through. DB 3C air pipe corroded through. Middle mast house bulkhead corroded through. On hold 2 PS three hatch coaming frames cracked. FP air pipe corroded through. On hold 3 hatchcoaming four frames cracked. QCV on service DO tank leaking. Fuel pipe for caterpillar DG improper. QCV on DO settling tank inoperative. DO5 air pipe corroded through. DO4 air pipe corroded through. Emergency DG not as required. On all fuel tanks spring return valves on sight glasses blocked with wire. On ME cylinder 1 cooling water leaking. ER bilge has to be dried and cleaned. Bilge tank with improper piping arrangements, which require the tank cover to be open. Synchronisation between DG 1 an3 and DG 1 and 2 impossible. Meat room temperature –10 °C. Abandon ship drill failed. ISM failed.
10/01/2005
Koper /

KHALIFEH LIVESTOCK

Livestock
7026871
3.356 / Honduras / Sea Shipping & Chartering
Beirut
Lebanon / Croatian Register of Shipping / Detained for 3 days.
12 recorded deficiencies.
Both wheelhouse wipers inoperative. Funnel damper sized. In FCSL STB two frames damaged. Air vent covers sized. Injector cooling water pipe made of rubber. Compressor cooling water pipe made of rubber. ER STB 3 frames bent. DG cooling water pump not fixed on the base. ER fire alarms inoperative. Life boat engine inoperative. QCV on fuel tank inoperative.
14/01/2005
Koper /

REENVI

General cargo
7111860
1596 / Albania / Zotaj Shipping
Durres
Albania / Albanian Register of Shipping / Detained for XX days.
16 recorded deficiencies.
Saloon window glass cracked. Saloon window out of hinges. Main magnetic compass missing. Gyrocompass inoperative. Charts not up to date. Rudder cracked. All ER air vent corroded through. Deck DG piping improper. Steering gear room entrance cover corroded through. Hatch covers on hold 2 corroded through. Hatch covers on hold 1 corroded through. On hold 1 more than 20 frames damaged, detached from hull or girders. On hold 1 several deck beams detached. Wheelhouse deck corroded through.
20/01/2005
Koper /

ATHOS

Bulk carrier
7617319
40.670 / Panama / GoldenPort
Shipmanagement
Athens
Greece / Lloyd Register of Shipping / Detained for 3 days.
25 recorded deficiencies.
ER air vent STB corroded through. ER air vent STB corroded through. ER air vent PS corroded through. Skylight corroded through. Accommodation bulkhead on captain deck corroded through. Radio room bulkhead corroded through. ER air vent remote dampers sized. Accommodation bulkhead on bridge deck corroded through. Galley store bulkhead corroded through. Smoke room air vent corroded through. Store room air vent corroded through. Oil spill room bulkhead corroded through. DG air vent corroded through. Lower stern light glass cracked. All navigational lights with improper glasses. Ball protection on FOT 5 air pipe corroded through. Ball protection on DO serv air pipe corroded through. Welding cracked on hatch cover on hold 2. Bulkhead in paint locker not air tight. Antistatic carpet in control room missing. Drain cooler leaking. Lead lamps on all ER fire sensors inoperative. OWS 15 ppm not adjusted. Abandon drill failed. ISM maintenance failed.
24/01/2005
Koper /

EUROFEEDER

Ro – ro ship
7946394
8.428 / Malta / Valiant Shipping
Athens
Greece / Registro Italiano Navale / Detained for 6 days.
35 recorded deficiencies.
Wheelhouse bulkhead corroded through. 2 green side lights glasses cracked. 2 red side lights glasses cracked. Stern navigational light missing. Magnetic compass with air bubbles. ER air fan bulkhead corroded through. ER air vent corroded through. ER fan switch detached. Accommodation door corroded through. DG room bulkhead corroded through. Two DG air vent doors corroded through. Store cover corroded through. Washing tank air pipe corroded through. Sopep room door corroded through. Cofferdam air pipe corroded through. AP air pipe ball missing. WBT 5 air pipe corroded through. FP air pipe ball protection corroded through. ART air pipe corroded through. FW air pipe corroded through. Galley water pipe not as required. High pressure double skin pipes on ME disconnected. On all 3 DG high pressure double skin lines not properly fitted. Aux engine bilge to be dried and cleaned. Water line for purifiers made of rubber. Hydrophore piping not as required. Boil filling water pipe not as required. AE bilge pipe PS leaking. High pressure pump on DG1 leaking. Return pipe from expansion tank not as required. Antistatic carpet missing. Day FO tank QCV inoperative. STB lifeboat engine inoperative. Abandon drill failed. ISM maintenance failed.
31/01/2005
Koper /

MEDITERRANEAN STAR

Chemical tanker
7320370
1.533 / Panama / Soysay Co.
Istanbul
Turkey / International Register of Shipping / 2 / Detained for 3 days.
9 recorded deficiencies.
Radio officer cabin bulkhead corroded through. Workshop air vent corroded through. CO2 air vent corroded through. FW tank air pipe corroded through. Bell missing. ME cooling pipe made of rubber. AE cooler pipe made of rubber. EM lighting inoperative. AIS inoperative.
02/02/2005
Koper /

HILDA

General cargo
8230259
2.516 / Russian Federation / Dedezdha Shipping management / Russian Maritime Register of Shipping / Detained for 4 days.
26 recorded deficiencies.
On wheelhouse both wipers inoperative. Three glasses on wheelhouse windows cracked. Charts not up to date. ER skylight corroded through. Welding room air vent corroded through. Battery room bulkhead corroded through. Rescue boat engine without fuel. Bridge bulkhead corroded through. On hold 3 hatch coaming cracked. On hold 3 bulkhead frames bent. On hold 1 bulkhead frames bent and detached. DB1 tank air pipe corroded through. DB1 STB air pipe corroded through. On FCSL hawser pipe cracked. In FCSL one frame heavy bent. Both ER air vent corroded through. Sanitary piping temporary repaired. Fresh water pipe made of rubber. EM fire pump insufficient pressure. In both lifeboats pumps inoperative. High pressure pump casing leaking. AE cooling water leaking. On ME double skin connection lines leaking. On ME 2 double skin alarm iniperatiove. Low pressure flanged joint shields missing. Doubler under stern anchor cracked.
07/02/2005
Koper /

EUROGALAXY

General cargo
8861668
1.719 / Georgia / European Corporation
Athens
Greece / International Register of Shipping / Detained for 3 days.
9 recorded deficiencies.
ER fire sensors inoperative. Sky light glass cracked. Stern navigational light glass cracked. Accommodation heating poor. Publications missing. EBED expired. Immersion suits lights missing. Filter on galley hood missing. Internal insulations poor.
10/02/2005
Koper /

MODISK

General cargo
8031392
1680 / Russian Federation / Adnan Saigun
Istanbul
Turkey / Russian Maritime Register of Shipping / Detained for 2 days.
17 recorded deficiencies.
Charts not up to date. Wheelhouse wipers inoperative. Accommodation air vent corroded through. BWT 3 air pipe corroded through. BWT 2 air pipe corroded through. BWT 5 air pipe corroded through. BWT 4 air pipe corroded through. BWT 7 air pipe corroded through. ME cylinder 3 cooling water leaking. ME cylinder no 8 cooling water leaking. Cooling water on cylinder No 2 leaking. QCV on fuel tanks inoperative. Fresh water line in ER temporary repaired. DG3 cooling water leaking. Bilge water pipe made of rubber. On DG 1 cooling water leaking. DG 2 can not be synchronised.
14/02/2005
Koper /

MARMARA – M

General cargo
7413945
1943 / Georgia / Uni Marine Management
Tarous
Syria / International Register of Shipping / Detained for 2 days.
18 recorded deficiencies.
Charts not up to date. Gyro repeaters inoperative. Wheelhouse bulkhead corroded through. Galley skylight corroded through. Funnel corroded through. Limit switches on davits inoperative. Emergency lightning on boat deck sized. DO C2 air pipe corroded through. In FCSL 4 frames bent. On hold 1 bottom plate of hatch covers corroded through, one frame detached. FP air pipe corroded through. DT air pipe corroded through. BW T4 fore and aft air pipes corroded through. Jacketed line connection not protected. Rubber pipe connection between settling tank and sludge tank with cover open. ER bilge dirty. ER fire sensors inoperative. Crew not using personal protective equipment.
23/02/2005
Koper /

SORMOVSKIY – 3006

General cargo
8035166
2491 / Russia / Volga Don Shipping
Rostov on Don
Russia / Russian Maritime Register of Shipping / Detained for 4 days.
7 recorded deficiencies.
Skylight corroded through. Funnel dampers corroded through. Deck on generator room corroded through. ON PS aft hull corroded through in two places. OWS not calibrated on 15 ppm. Low pressure flanged joints shields missing.
24/02/2005
Koper /

ASK

Cement carrier
5189136
836 / Panama / Trajekt d.o.o.
Split
Croatia / Bureau Veritas / Detained for 2 days.
10 recorded deficiencies.
AIS not installed. Wheelhouse bulkhead corroded through. Magnetic compass with big bubbles. AP air pipe ball protection detached. Under cable lifter hawser pipe plate detached. Hawser openings plates missing. Cargo pump room cover corroded through. Cargo compressor no 2 inoperative. Sludge tank gauge pipe not as required. Fuel pipe for DG 2 made of rubber.
25/02/2005
Koper /

LINZ

General cargo
7023805
4216 / St. Vincent & Grenadines / Argo Maritime
Varna
Bulgaria / Bulgarski Koraben
Registar / Detained for 2 days.
26 recorded deficiencies.
Gasket holder on hatch covers bad. Bulkhead between hold 1 and fire pump room corroded through. Hold air vent corroded through. Bridge air vent corroded through. Boat swain store window made of Plexiglas. Galley hood dirty. On service tank improper valve. QCV on service tank disconnected. Gauge on service tank improper. ER bilge dirty. ME dirty. Funnel dampers corroded through. Skylight holed. Wheelhouse bulkhead corroded through. Accommodation air vent corroded through. Accommodation bulkhead corroded through. Bridge PS air vent corroded through. ER door corroded through. DB4 air pipe corroded through. WT3 air pipe corroded through. WT1 air pipes corroded through. Scuttle glass on front bridge missing. Low pressure flange joints missing. Abandon drill failed. FF appliances not as required. ISM failed.
04/03/2005
Koper /

KRIS

General cargo
7232652
1510 / Comoros / Glas Trading
Piraeus
Greece / International Naval Surveys Bureau / Detained for 4 days.
33 recorded deficiencies
Wheelhouse bulkhead corroded through. Accommodation air vent dampers sized. Magnetic compass with air bubbles. Horn inoperative. Two red lights for ship not under command with improper glass. ER skylight corroded through. Fast rescue boat deflated. One stern light missing. On life rafts weak links missing. Steering gear room air vent corroded through. On hold 2 hatch covers frames corroded through. Captain and chief engineers air conditions installed out of class condition. Front bridge bulkhead corroded through. Cargo opening on hatch covers not bolted. Delivery fuel line for emergency fire pump made of rubber. Both hawser pipes cracked. Windlass bad plate corroded through. On FCSL anchor light missing. QCV on fuel tank for emergency fire pump sized. On hold 1 FWD entrance cover corroded through. DB1 STB air pipe corroded through. Captain cabin bulkhead corroded through. Hydrophore gauges not as required. Bilge pump leaking. On both DGs guards missing. OWS with rubber pipe connections. Alleged illegal discharge pipe installed to open bilge tank. On low pressure line flanged joints shields missing. Deck over hidrophore and hatch covers hydraulic pumps corroded through with water leaking on hydraulic pumps. Insufficient quantity of food on board. Crew do not wear personal protective equipment. STB gangway damaged- unusable. ISM maintenance failed.
10/03/2005
Koper /

NEJLA 1

General cargo
7321283
2569 / Georgia / Harmanda Shipping
Istanbul
Turkey / International Register of Shipping / Detained for 4 days.
26 recorded deficiencies
Charts not up to date. Steering magnetic compass with air bubbles. EPIRB inoperative. On alleyway door glass cracked. Galley air vent corroded through. Delivery fuel pipe for deck generator made of rubber. Self ignition lights inoperative. Galley sky light holed. Stern light casing damaged. ER air vent damper sized. On hold 1 winch brake handle not as required. Gauge on emergency generator fuel tank not as required. In paint room 3 frames bent. On FO 3 DB tank bulkhead corroded through, tank communicate with ballast tank 3 PS. PS hawser pipe temporary repaired. FP air pipe corroded through. FP manhole cover not bolted. Emergency fire pump insufficient pressure. ER fire sensors inoperative. Pipes on bilge pump temporary repaired. DG 2 inoperative. DG 1 and deck generator can not be synchronised. Cooling water on cylinder 3 leaking. Low pressure flanged joints shields missing on ME and DGs. When filling DB3 ballast tank minor pollution occurred. ISM maintenance failed.
11/03/2005
Koper /

EDARTE

General cargo
7397971
1628 / Albania / Zotaj Shipping
Durres
Albania / Albanian Register of Shipping / Detained for 5 days.
18 recorded deficiencies
Crew without medical examination. Emergency fire pump inoperative. Insulation in steering gear room wetted. ER bilge dirty. Heating inoperative. Nautical publications expired. Fire hoses leaking. Life boat engine inoperative. Lifeboat not properly maintained. Tracking pendants missing. Self igniting lights inoperative. Galley filters missing. Galley dirty. Sanitary facilities dirty. Rubber gaskets in bad condition. Fire boxes in bad condition. ISM maintenance failed.
16/03/2005
Koper /

MIDLAND 201

General cargo
8846761
2554 / Malta / Midland Shipping
Toronto
Canada / Russian Maritime Register of Shipping / Detained for 2 days.
10 recorded deficiencies
Funnels corroded through. Wheelhouse door corroded through. Master cabin bulkhead corroded through. Ch. Eng. Cabin bulkhead corroded through. Mess room bulkhead corroded through. Magnetic compass gimble arrangement sized. Rubber pipe for cleaning installed on DO tank. Grey water pipe made of rubber. Water pipe for hot water partially made of rubber.
23/03/2005
Koper /

ADAL

General cargo
8883654
437 / Albania / Mema Osman
Durres
Albania / Albanian Register of Shipping / Detained for 27 days.
47 recorded deficiencies
Charts not up to date. Electric power supply to Navtex not available. Electric power supply to AIS not available. Main magnetic compass missing. Steering magnetic compass inoperative. Rudder indicator missing. Radar inoperative. Two red lights for ship not under command missing. All navigational lights with improper glass. Whistle inoperative. On FCSL bell missing. Both MOB expired. Captain cabin window cracked. Mess room scuttle window glass cracked. In officers saloon 2 windows glasses cracked. In FCSL scuttle glass crashed. Accommodation door corroded through. On all doors gaskets missing. On hold 2 air vent damper missing. On hold 1 air vent cut. On all hatch covers gaskets missing. On hold 1 hatch covers corroded through. On hold 2 hatch covers corroded through. On hold 2 hatch entrance cover corroded through. Bulwark corroded through on several places. Inn FCSL STB hull holed. Toilet bulkhead corroded through. Front bridge bulkhead corroded through. FCSL bulkhead corroded through. On FCSL deck corroded through in two places. Emergency lighting inoperative. All portable extinguishers empty. Double skin fuel line on ME missing. Radar transponder missing. MMSI missing. GMDSS radio equipment power supply not available. Ropes in bad condition. Windlass base corroded through. DG 1 inoperative. DG 2 inoperative. Port DG inoperative. Air compressor insufficient pressure. Steering gear not working properly. Fuel line leaking. Antistatic carpet missing. Captain cabin bulkhead corroded through. Aft bridge bulkhead corroded through.
24/03/2005
Koper /

ANNA