13 Februar 2012 / QUESTIONNAIRE for AEROMAT , COOKING and intensive cooling installations

Form completed by

Customer

Project / offer / order no. Pos.:

Date

1.  Size of installation

x = trolleys

2.  Smoke trolleys

Type ☐ floor travelling trolley

☐ hanging trolley

Dimensions x x mm (length x width x height)

Height of rail mm

Diameter of roller mm

Load capacity kg per trolley

Use of fork lifts inside the Chamber ☐

Gauge mm

3.  Delivery quantity pieces

4.  Processes ☐ cooking (Aeromat, Cooking Installation)

☐ drying (Aeromat)

☐ hot smoking (Aeromat)

☐ baking up to 160°C (Aeromat)

☐ showering (Aeromat, Cooking Installation, Intensive Cooling Installation)

☐ cold air cooling (Intensive Cooling Installation)

☐ ice water showering (Intensive Cooling Installation)

5.  Product(s) Please complete the form

product name / ingredients / caliber / size / length / casing
1.
2.
3.
4.


☐ hanging product

☐ lying product

☐ tower

Previous process in the factory

Following process in the factory

6.  Specification of equipment

☐ new investment

☐ replacement of existing equipment

Description of existing equipment

Specification of new equipment

Machine unit ☐ on top ☐ at rear wall

Heating ☐ steam (6 bar) ☐ steam (4 bar)

(only to complete with AEROMAT) ☐ direct gas ☐ liquid gas

☐ electricity ☐ natural gas

☐ thermo oil caloric value kwh/m³

Type Temperature °C

Humidification ☐ steam (0,7 bar)

(only to complete with AEROMAT and Cooking Installation or Cooling Installation with steam valve)

(only to complete with AEROMAT) ☐ water (rel. humidity max. 80 %, not applicable for cooking processes)

☐ steam generator VEMAG (DE48, DE96, DE 120, max. 5 trolleys, long cooking times)

Cooling system ☐ Freon

(only to complete with Intensive ☐ Ammonia
Cooling Installation or Aeromat ☐ Ethylene-Glycol concentration %

with cold smoke device, see ☐ Propylene-Glycol concentration %

Accessories) Temperature of cooling media °C (Intensive Cooling Installations – 10°C)

Cleaning of machine unit Cooking Installations as well as Intensive Cooling Installations are delivered without cleaning of machine unit in their basic version.

☐ semi-automatic foam cleaning (standard in AEROMAT)

☐ full automatic foam cleaning

☐ Chamber cleaning

☐ cleaning of the machine unit with steam

Position of cleaning distribution ☐ left ☐ front

☐ right ☐ back side

Cold water supply bar °C

Compressed air 6 - 10 bar instrument air, with lifting doors 8 - 10 bar.

Door ☐ single wing for single-row design

☐ double wing for two-row design

☐ pneumatic door opening

☐ transit

☐ lifting door

☐ roller door

(only available with Intensive Cooling Installation without steam cooking)

☐ window

Entry /exit ☐ entry bridge

☐ short metal entry ramp (floor - 33 mm)

☐ long metal entry ramp (directly on the floor)

Chamber floor with Pagel cement ☐ (Hygiene reasons)

Door opening (single-row) ☐ left ☐ right

Door opening exit (single-row) ☐ left ☐ right

(only to complete with Transit)

Voltage V, 3 Phase Frequence Hz

7.  Accessories

☐ shower in the Aeromat
(standard in Cooking and Intensive Cooling Installations)

☐ floor drain (DN 100) for showering

☐ vertical outlet

☐ horizontal outlet

☐ siphon

(not available in combination with automatic chamber cleaning)

☐ drain flap

(not available in combination with automatic chamber cleaning)

☐ automatic door opener (for water outlet during showering process if no floor drain is installed)

☐ exhaust air pipe (length 6 m)

other length m

☐ smoke trolleys quantity

☐ smoke sticks quantity

Accessories (only available with AEROMAT)

☐ Smoke Generator H 508 up to max. 6-trolley installations

☐ Smoke Generator H 508 with voltage transformer (voltage >400V or voltage < 400V)

☐ Smoke Generator H 504 up to max. 12 trolley installations

☐ Smoke Generator H 504 with voltage transformer (voltage >400V or voltage < 400V)

☐ Friction Smoke Generator H 501 up to max. 4 trolley installations

☐ Steam Smoke Generator H 507 up to max. 6 trolley installations

☐ TARBER Liquid Smoke System

Position of Smoke Generator

☐ smoke pipes

☐ recycling pipe (for H501) length m

☐ electric heater for temperatures max. 160°C

☐ cold smoke device

☐ Exhaust Air Cleaning System / Afterburner Installation TNV

8.  Switch Board / MICROMAT C7

Size ☐ 8 ̎ display (standard) ☐ 10 ̎ display

Indication in ☐ °C ☐ °F

Position of control display ☐ left ☐ front

☐ right ☐ back side

☐ on the door ☐ other position

please define

Position of control cabinet ☐ left ☐ front

☐ right ☐ back side

☐ on the door ☐ other position

please define

Length of sensor cable m (20 m included in delivery)

☐ water protection cap

☐ RFID Log-in

☐ chamber lightning (standard in Germany => 5 trolleys depth)

☐ barcode scanner

☐ Ethernet interface

☐ LDS Quantity of Installations to be connected to LDS

☐ LDS already existing, no. of existing LDS

☐ electric material

☐ only cables

☐ cable grate

☐ cableways

length of electric material m

9.  Assembly & start-up

Chief assembly ☐ Technical start-up VEMAG ☐

Assembly VEMAG ☐ Technological start-up VEMAG ☐

Electrical installation VEMAG ☐

10.  Customer’s plant

Handling most narrow way length x width x height

lift length x width x height

max. transport weight kg

11.  Schedule

Order week/year

Delivery week/year

Start-up week/year

12.  Miscellaneous

Decision criteria

Additional information

Date, customer’s signature Date, VEMAG representative