Section 08360

Model H-16 Insulator

SECTIONAL STEEL OR COMBINATION OF STEEL & ALUMINUM COMBINATION OVERHEAD DOORS

1 PART 1: GENERAL

1.1 SECTION INCLUDES

A. operated overhead sectional door

(Manual or Motor)

B. 1 ¾” Steel foamed-in-place construction. R-value 16

C. Operating hardware and supports

1.2 REFERENCES

A. ANSI A216.1-Section Overhead Type Door (NAGDM 102).

1.3 SYSTEM DESCRIPTION

A. Sections to be Hot-dipped G-90 galvanized steel-standard 26 gauge; built in reinforcing plates for hardware attachment; galvanized steel end caps

B. operating style with track and hardware.

(Standard Lift, High Lift, Vertical Lift, or Low Headroom)

Track (2” or 3”)

1.4 SUBMITTALS

A. Submit shop drawings and product data under provisions of section 01300.

B. Shop Drawings: Indicate opening dimensions and required tolerances, connection details, anchorage spacing, hardware locations, installation details.

C. Product Data: Provide component construction, anchorage method, and hardware.

1.5 OPERATION AND MAINTENANCE DATA

A. Submit under provisions of Section 01700.

B. Maintenance Data: Include data for lubrication frequency and spare part sources.

1.7 QUALIFICATIONS

A. Manufacturer: Company specializing in manufacturing the Products specified in this section with minimum (5) years documented experience.

B. Installer: Company specializing in performing the work of this section with minimum (5) years approved by manufacturer.

1.8 WARRANTY

A.  Five (5) year warranty on sections only

B.  Standard one year warranty applies to the rest of the door.

1  PART 2 PRODUCTS

2.1 MANUFACTURERS

Standard: For purposes of designating type and quality of work under this Section, Drawings and Specifications are based on products manufactured or Furnished by ARM-R-LITE DOOR MANUFACTURING CO. 800-554-5816 – ext 4016 908-754-6522-fax contact Shannon.

1.  Door Type: H-16 MODEL by ARM-R-LITE.

2.2 MATERIALS

A.  Exterior 26 gauge skins & Interior 28 gauge skins

B.  finish.

(White standard-custom color available for upcharge)

C.  Sections to contain

(24” x 12” lites, 24” x 8” lites or full vision aluminum sections up to 26’2” wide available: extruded aluminum sections of welded construction provide 1/8”, 1/4” or 7/16” insulated glass)

2.4 DOOR COMPONENTS

A. Hardware: All hinges and fixtures made of 14 gauge galvanized steel. Full Floating, ball bearing rollers have hardened steel races, and roller sizes will be adequate for design requirements and limitations.

Heavy-duty, fully adjustable roller brackets are attached to each end cap to provide an easy adjustment of the door to the job for proper seal. All hardware is heavy-duty and rust-resistant with galvanized fasteners. Heavy-duty rollers contain steel ball bearings in case-hardened steel races.

B. Weather-strip:

(Perimeter seal for steel jambs, vinyl door stops for wood jambs)

C. Operation

(Motor or Manual operation)

D. Track: Track is and shall be

(2” or 3”) (Bracket to wood, angle to wood, or angle to steel

E. Torsion Spring with a

(Tube shaft or an extended solid shaft)

F. Sectional Door Assembly: Steel door assembly with tongue & groove construction to form weather tight joints and provide full-width interlocking structural rigidity.

G. Wind load Design: ANSI/AGDM 102 standards and as required by local codes.

H. Lock:

(Interior slide bolt or keyed cylinder lock or no lock)

2.5 FINISH

A.

(White, standard-custom color available for upcharge)

2.6 MOTOR OPERATORS

Arm-R-Lite Model Motor operators available for every door and track

situation.

(Trolley operators for standard & low headroom applications)

(Jackshaft operators for high lift and vertical lift applications)

3 PARTS 3: EXECUTION

3.1  INSPECTION

A. Verify that wall openings are ready to receive work and opening dimensions and tolerances are within specified limits.

B. Beginning of installation means acceptance of existing surfaces.

3.2  PREPARATION

A. Prepare opening to permit correct installation of door unit.

3.3  INSTALLATION

A. Install door unit assembly in accordance with manufacturer’s instructions.

B. Anchor assembly to wall construction and building framing without distortion or stress

C. Secure tracks to structural members only.

D. Fit and align door assembly including hardware, level and plumb, to provide smooth operation.

E. Coordinate installation of sealant and backing materials at frame perimeter as Specified in Section 07900, JOINT SEALERS.

F. Install perimeter trim and closures.

3.4  TOLERANCES

A. Maintain dimensional tolerances and alignment with adjacent work.

B. Maximum variation from Plumb: 1/8 inch.

C. Maximum variation from Level: 1/8 inch.

D. Longitudinal or Diagonal Warp: Plus or minus 1/8 inch from 10 Ft. straight edge.

3.5  ADJUSTING

A.  Adjust door assembly to smooth operation.

3.6  CLEANING

A. Clean doors, frames and glass.

B. Remove labels and visible markings.

END OF SECTION